VAR-202006-0901 CVE-2020-14442 plural NETGEAR On the device OS Command injection vulnerabilities CVSS V2: 5.8
CVSS V3: 8.8
Severity: HIGH
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary shell commands with the help of specially crafted requests
VAR-202006-0330 CVE-2020-12043 Baxter Spectrum Vulnerability in manipulating resources after expiration or release in CVSS V2: 7.5
CVSS V3: 9.8
Severity: CRITICAL
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when configured for wireless networking the FTP service operating on the WBM remains operational until the WBM is rebooted. Baxter Spectrum Vulnerable to post-expiration or post-release resource manipulation vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Baxter WBM and Baxter Spectrum are both products of Baxter. Baxter WBM is a wireless battery module for Baxter products. Baxter Spectrum is an infusion pump. There is a security vulnerability in Baxter Spectrum WBM. Attackers can use this vulnerability to gain access to the FTP service with the help of a specially crafted request
VAR-202006-1820 CVE-2019-18254 BIOTRONIK CardioMessenger II Vulnerability regarding lack of encryption of critical data in CVSS V2: 2.1
CVSS V3: 4.6
Severity: MEDIUM
BIOTRONIK CardioMessenger II, The affected products do not encrypt sensitive information while at rest. An attacker with physical access to the CardioMessenger can disclose medical measurement data and the serial number from the implanted cardiac device the CardioMessenger is paired with. BIOTRONIK CardioMessenger II There is a vulnerability in the lack of encryption of critical data.Information may be obtained. Biotronik CardioMessenger II-S is a portable medical monitoring device of German Biotronik company, which is mainly used to monitor implantable devices such as cardiac pacemakers. There are security vulnerabilities in Biotronik CardioMessenger II-S T-Line T4APP version 2.20 and II-S GSM T4APP version 2.20
VAR-202006-0936 CVE-2020-14439 plural NETGEAR On the device OS Command injection vulnerabilities CVSS V2: 5.8
CVSS V3: 8.8
Severity: HIGH
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request
VAR-202006-0331 CVE-2020-12045 Baxter Spectrum WBM trust management issue vulnerability CVSS V2: 7.5
CVSS V3: 9.8
Severity: CRITICAL
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) when used in conjunction with a Baxter Spectrum v8.x (model 35700BAX2), operates a Telnet service on Port 1023 with hard-coded credentials. Baxter Spectrum Contains a vulnerability in the use of hard-coded credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Baxter WBM and Baxter Spectrum are both products of Baxter. Baxter WBM is a wireless battery module for Baxter products. Baxter Spectrum is an infusion pump. The WBM used in Baxter Spectrum has a security vulnerability. Attackers can use hard-coded credentials to exploit this vulnerability to run Telnet services
VAR-202006-0904 CVE-2020-14445 WSO2 Identity Server and IS as Key Manager Cross-site scripting vulnerability in CVSS V2: 3.5
CVSS V3: 5.4
Severity: MEDIUM
An issue was discovered in WSO2 Identity Server through 5.9.0 and WSO2 IS as Key Manager through 5.9.0. A potential Reflected Cross-Site Scripting (XSS) vulnerability has been identified in the Management Console Basic Policy Editor user Interface. The vulnerability stems from the lack of correct verification of client data in WEB applications. An attacker can use this vulnerability to execute client code
VAR-202006-0826 CVE-2019-18248 BIOTRONIK CardioMessenger II Vulnerability in plaintext transmission of important information in CVSS V2: 3.3
CVSS V3: 4.3
Severity: MEDIUM
BIOTRONIK CardioMessenger II, The affected products transmit credentials in clear-text prior to switching to an encrypted communication channel. An attacker can disclose the product’s client credentials for connecting to the BIOTRONIK Remote Communication infrastructure. BIOTRONIK CardioMessenger II Includes a vulnerability in the transmission of important information in clear text.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Biotronik CardioMessenger II-S is a portable medical monitoring device of German Biotronik company. It is mainly used to monitor implantable devices such as cardiac pacemakers
VAR-202006-0329 CVE-2020-12041 Baxter Spectrum Vulnerability in improper permission assignment for critical resources in CVSS V2: 7.5
CVSS V3: 9.4
Severity: CRITICAL
The Baxter Spectrum WBM (v17, v20D29, v20D30, v20D31, and v22D24) telnet Command-Line Interface, grants access to sensitive data stored on the WBM that permits temporary configuration changes to network settings of the WBM, and allows the WBM to be rebooted. Temporary configuration changes to network settings are removed upon reboot. Baxter Spectrum Includes a vulnerability in improper permission assignment for critical resources.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Baxter WBM and Baxter Spectrum are both products of Baxter. Baxter WBM is a wireless battery module for Baxter products. Baxter Spectrum is an infusion pump. The WBM used in Baxter Spectrum has security vulnerabilities
VAR-202006-0087 CVE-2020-12884 Arm Mbed OS Out-of-bounds read vulnerability in CVSS V2: 6.4
CVSS V3: 9.1
Severity: CRITICAL
A buffer over-read was discovered in the CoAP library in Arm Mbed OS 5.15.3. The CoAP parser is responsible for parsing received CoAP packets. The function sn_coap_parser_options_parse_multiple_options() parses CoAP options that may occur multiple consecutive times in a single packet. While processing the options, packet_data_pptr is accessed after being incremented by option_len without a prior out-of-bounds memory check. The temp_parsed_uri_query_ptr is validated for a correct range, but the range valid for temp_parsed_uri_query_ptr is derived from the amount of allocated heap memory, not the actual input size. Therefore the check of temp_parsed_uri_query_ptr may be insufficient for safe access to the area pointed to by packet_data_pptr. As a result, access to a memory area outside of the intended boundary of the packet buffer is made. Arm Mbed OS Exists in an out-of-bounds read vulnerability.Information is obtained and service operation is interrupted (DoS) It may be put into a state. ARM Mbed OS is a set of open source embedded operating system dedicated to the Internet of Things of the British ARM company. CoAP library is one of the Constrained Application Protocol (CoAP) libraries. An attacker can use this vulnerability to consume all available resources and cause a denial of service
VAR-202006-0930 CVE-2020-14433 plural NETGEAR Injection vulnerabilities in devices CVSS V2: 5.2
CVSS V3: 6.8
Severity: MEDIUM
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBK842 before 3.2.15.25, RBR850 before 3.2.15.25, RBS850 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, and RBS750 before 3.2.15.25. plural NETGEAR A device contains an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Injection vulnerabilities exist in many NETGEAR products. The vulnerability stems from the fact that the network system or product lacks the correct verification of the user input data during the operation process of the user inputting the construction command, data structure or record, and the special elements are not filtered or correctly filtered, resulting in the analysis or analysis of the system or product. The explanation is wrong. No detailed vulnerability details are currently provided
VAR-202006-0333 CVE-2020-12048 Phoenix Hemodialysis Delivery System SW Vulnerability in plaintext transmission of important information in CVSS V2: 5.0
CVSS V3: 7.5
Severity: HIGH
Phoenix Hemodialysis Delivery System SW 3.36 and 3.40, The Phoenix Hemodialysis device does not support data-in-transit encryption (e.g., TLS/SSL) when transmitting treatment and prescription data on the network between the Phoenix system and the Exalis dialysis data management tool. An attacker with access to the network could observe sensitive treatment and prescription data sent between the Phoenix system and the Exalis tool
VAR-202006-1819 CVE-2019-18256 BIOTRONIK CardioMessenger II Vulnerability related to password management function in CVSS V2: 2.1
CVSS V3: 4.6
Severity: MEDIUM
BIOTRONIK CardioMessenger II, The affected products use individual per-device credentials that are stored in a recoverable format. An attacker with physical access to the CardioMessenger can use these credentials for network authentication and decryption of local data in transit. BIOTRONIK CardioMessenger II Contains a vulnerability related to the password management function.Information may be obtained. Biotronik CardioMessenger II-S is a portable medical monitoring device of German Biotronik company, which is mainly used to monitor implantable devices such as cardiac pacemakers. Biotronik CardioMessenger II-S T-Line T4APP version 2.20 and II-S GSM T4APP version 2.20 have security vulnerabilities that originate from the program's ability to recover the credentials of each device stored in a format
VAR-202006-0905 CVE-2020-14446 WSO2 Identity Server and IS as Key Manager Open redirect vulnerability in CVSS V2: 5.8
CVSS V3: 6.1
Severity: MEDIUM
An issue was discovered in WSO2 Identity Server through 5.10.0 and WSO2 IS as Key Manager through 5.10.0. An open redirect exists. Attackers can use this vulnerability to redirect users to arbitrary external links by constructing URLs to carry out phishing attacks
VAR-202006-0827 CVE-2019-18252 BIOTRONIK CardioMessenger II Authentication vulnerabilities in CVSS V2: 3.3
CVSS V3: 4.3
Severity: MEDIUM
BIOTRONIK CardioMessenger II, The affected products allow credential reuse for multiple authentication purposes. An attacker with adjacent access to the CardioMessenger can disclose its credentials used for connecting to the BIOTRONIK Remote Communication infrastructure. BIOTRONIK CardioMessenger II There is an authentication vulnerability in.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. Biotronik CardioMessenger II-S is a portable medical monitoring device of German Biotronik company. It is mainly used to monitor implantable devices such as cardiac pacemakers. The Biotronik CardioMessenger II-S T-Line T4APP version 2.20 and II-S GSM T4APP version 2.20 have an authorization issue vulnerability that results from the program using the same credentials for multiple authentications
VAR-202006-1810 CVE-2020-12024 Baxter ExactaMix EM 2400 and EM1200 Vulnerability regarding lack of authentication in CVSS V2: 3.6
CVSS V3: 6.1
Severity: MEDIUM
Baxter ExactaMix EM 2400 versions 1.10, 1.11, 1.13, 1.14 and ExactaMix EM1200 Versions 1.1, 1.2, 1.4 and 1.5 does not restrict access to the USB interface from an unauthorized user with physical access. Successful exploitation of this vulnerability may allow an attacker with physical access to the system the ability to load an unauthorized payload or unauthorized access to the hard drive by booting a live USB OS. This could impact confidentiality and integrity of the system and risk exposure of sensitive information including PHI. Baxter ExactaMix EM 2400 and EM1200 Exists in a vulnerability related to lack of authentication.Information may be obtained and tampered with. Baxter ExactaMix EM2400 and ExactaMix EM1200 are both an automated drug mixing system of Baxter. Baxter ExactaMix EM2400 and EM1200 have an access control error vulnerability
VAR-202006-0932 CVE-2020-14435 plural NETGEAR Injection vulnerabilities in devices CVSS V2: 5.8
CVSS V3: 8.8
Severity: HIGH
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects SRK60 before 2.5.2.104, SRS60 before 2.5.2.104, SRR60 before 2.5.2.104, SRK60B03 before 2.5.2.104, SRK60B04 before 2.5.2.104, SRK60B05 before 2.5.2.104, and SRK60B06 before 2.5.2.104. plural NETGEAR A device contains an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Injection vulnerabilities exist in many NETGEAR products. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request
VAR-202006-0934 CVE-2020-14437 plural NETGEAR On the device OS Command injection vulnerabilities CVSS V2: 5.8
CVSS V3: 8.8
Severity: HIGH
Certain NETGEAR devices are affected by command injection by an unauthenticated attacker. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR On the device OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. Attackers can use this vulnerability to execute arbitrary Shell commands on the system by sending a specially crafted request
VAR-202006-0929 CVE-2020-14432 plural NETGEAR Cross-site request forgery vulnerability in device CVSS V2: 6.8
CVSS V3: 8.8
Severity: HIGH
Certain NETGEAR devices are affected by CSRF. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR A cross-site request forgery vulnerability exists in the device.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. The vulnerability stems from the fact that the WEB application does not fully verify whether the request comes from a trusted user. An attacker can use this vulnerability to send unexpected requests to the server through the affected client
VAR-202006-0903 CVE-2020-14444 WSO2 Identity Server and IS as Key Manager Cross-site scripting vulnerability in CVSS V2: 3.5
CVSS V3: 5.4
Severity: MEDIUM
An issue was discovered in WSO2 Identity Server through 5.9.0 and WSO2 IS as Key Manager through 5.9.0. A potential Reflected Cross-Site Scripting (XSS) vulnerability has been identified in the Management Console Policy Administration user interface. The vulnerability stems from the lack of correct verification of client data in WEB applications. An attacker can use this vulnerability to execute client code
VAR-202006-0928 CVE-2020-14431 plural NETGEAR Inadequate protection of credentials on devices CVSS V2: 3.3
CVSS V3: 8.8
Severity: HIGH
Certain NETGEAR devices are affected by disclosure of administrative credentials. This affects RBK752 before 3.2.15.25, RBK753 before 3.2.15.25, RBK753S before 3.2.15.25, RBR750 before 3.2.15.25, RBS750 before 3.2.15.25, RBK842 before 3.2.15.25, RBR840 before 3.2.15.25, RBS840 before 3.2.15.25, RBK852 before 3.2.15.25, RBK853 before 3.2.15.25, RBR850 before 3.2.15.25, and RBS850 before 3.2.15.25. plural NETGEAR Devices contain vulnerabilities in insufficient protection of credentials.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be put into a state. NETGEAR RBK752, etc. are all home WiFi systems of NETGEAR. There are security vulnerabilities in many NETGEAR products. Attackers can use this vulnerability to obtain management credentials