VAR-202502-0689 CVE-2025-25744 D-Link Systems, Inc.  of  dir-853  Out-of-bounds write vulnerability in firmware CVSS V2: 10.0
CVSS V3: 9.8
Severity: CRITICAL
D-Link DIR-853 A1 FW1.20B07 was discovered to contain a stack-based buffer overflow vulnerability via the Password parameter in the SetDynamicDNSSettings module. D-Link Systems, Inc. of dir-853 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. D-Link DIR-853 is a router from D-Link, a Chinese company. No detailed vulnerability details are currently provided
VAR-202502-0304 CVE-2025-25743 D-Link Systems, Inc.  of  dir-853  Command injection vulnerability in firmware CVSS V2: 8.3
CVSS V3: 7.2
Severity: HIGH
D-Link DIR-853 A1 FW1.20B07 was discovered to contain a command injection vulnerability in the SetVirtualServerSettings module. D-Link Systems, Inc. of dir-853 Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. D-Link DIR-853 is a router from D-Link, a Chinese company. No detailed vulnerability details are currently available
VAR-202502-0440 CVE-2025-25742 D-Link Systems, Inc.  of  dir-853  Out-of-bounds write vulnerability in firmware CVSS V2: 10.0
CVSS V3: 9.8
Severity: CRITICAL
D-Link DIR-853 A1 FW1.20B07 was discovered to contain a stack-based buffer overflow vulnerability via the AccountPassword parameter in the SetSysEmailSettings module. D-Link Systems, Inc. of dir-853 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. D-Link DIR-853 is a router from D-Link, a Chinese company. No detailed vulnerability details are currently available
VAR-202502-2079 No CVE The wireless AC controller of Shanghai Boda Data Communication Co., Ltd. has a logical defect vulnerability CVSS V2: 2.1
CVSS V3: -
Severity: LOW
Shanghai Boda Data Communication Co., Ltd. is a company that focuses on the research and development, production, sales and service of data network products. Shanghai Boda Data Communication Co., Ltd.'s wireless AC controller has a logical defect vulnerability that can be exploited by attackers to obtain sensitive information.
VAR-202502-0818 CVE-2025-25528 WAVLINK WL-WN575A3 Buffer Overflow Vulnerability CVSS V2: 3.6
CVSS V3: 5.1
Severity: MEDIUM
Multiple buffer overflow vulnerabilities in Wavlink WL-WN575A3 RPT75A3.V4300, which are caused by not performing strict length checks on user-controlled data. By successfully exploiting the vulnerabilities, attackers can crash the remote devices or execute arbitrary commands without any authorization verification. WAVLINK WL-WN575A3 is a wireless network signal extender from WAVLINK, a Chinese company. No detailed vulnerability details are currently provided
VAR-202502-1397 CVE-2025-25524 TOTOLINK  of  x6000r  Classic buffer overflow vulnerability in firmware CVSS V2: 3.6
CVSS V3: 5.1
Severity: MEDIUM
Buffer overflow vulnerability in TOTOLink X6000R routers V9.4.0cu.652_B20230116 due to the lack of length verification, which is related to the addition of Wi-Fi filtering rules. Attackers who successfully exploit this vulnerability can cause the remote target device to crash or execute arbitrary commands. TOTOLINK of x6000r Firmware has a classic buffer overflow vulnerability.Information may be obtained and information may be tampered with. TOTOLINK X6000R is a wireless router from China's TOTOLINK Electronics. TOTOLINK X6000R has a buffer overflow vulnerability, which is caused by a boundary error when the application processes untrusted input. No detailed vulnerability details are currently provided
VAR-202502-0405 CVE-2024-27781 fortinet's  FortiSandbox  Cross-site scripting vulnerability in CVSS V2: -
CVSS V3: 7.1
Severity: HIGH
An improper neutralization of input during web page generation ('cross-site scripting') in Fortinet FortiSandbox at least versions 4.4.0 through 4.4.4 and 4.2.0 through 4.2.6 and 4.0.0 through 4.0.4 and 3.2.0 through 3.2.4 and 3.1.0 through 3.1.5 and 3.0.0 through 3.0.7 allows an authenticated attacker to execute unauthorized code or commands via crafted HTTP requests. fortinet's FortiSandbox Exists in a cross-site scripting vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
VAR-202502-0112 CVE-2025-24956 Siemens OpenV2G Buffer Overflow Vulnerability CVSS V2: 4.9
CVSS V3: 6.2
Severity: Medium
A vulnerability has been identified in OpenV2G (All versions < V0.9.6). The OpenV2G EXI parsing feature is missing a length check when parsing X509 serial numbers. Thus, an attacker could introduce a buffer overflow that leads to memory corruption. Siemens OpenV2G is an open source implementation of a V2G infrastructure component of Siemens, Germany. Siemens OpenV2G has a buffer overflow vulnerability
VAR-202502-0125 CVE-2025-24812 Siemens SIMATIC S7-1200 CPU Family Denial of Service Vulnerability (CNVD-2025-03036) CVSS V2: 7.8
CVSS V3: 6.5
Severity: High
A vulnerability has been identified in SIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212C AC/DC/Rly (6ES7212-1BE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212C DC/DC/DC (6ES7212-1AE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212C DC/DC/Rly (6ES7212-1HE40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212FC DC/DC/DC (6ES7212-1AF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1212FC DC/DC/Rly (6ES7212-1HF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214C AC/DC/Rly (6ES7214-1BG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214C DC/DC/DC (6ES7214-1AG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214C DC/DC/Rly (6ES7214-1HG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214FC DC/DC/DC (6ES7214-1AF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1214FC DC/DC/Rly (6ES7214-1HF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215C AC/DC/Rly (6ES7215-1BG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215C DC/DC/DC (6ES7215-1AG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215C DC/DC/Rly (6ES7215-1HG40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215FC DC/DC/DC (6ES7215-1AF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1215FC DC/DC/Rly (6ES7215-1HF40-0XB0) (All versions < V4.7), SIMATIC S7-1200 CPU 1217C DC/DC/DC (6ES7217-1AG40-0XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL (6AG2212-1AE40-1XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL (6AG2214-1AG40-1XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214FC DC/DC/DC (6AG1214-1AF40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1214FC DC/DC/RLY (6AG1214-1HF40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-2XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-4XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215C DC/DC/DC (6AG1215-1AG40-5XB0) (All versions < V4.7), SIPLUS S7-1200 CPU 1215FC DC/DC/DC (6AG1215-1AF40-5XB0) (All versions < V4.7). Affected devices do not process correctly certain special crafted packets sent to port 102/tcp, which could allow an attacker to cause a denial of service in the device. SIMATIC S7-1200 CPU products are designed for discrete and continuous control in industrial environments such as global manufacturing, food and beverage, and chemical industries. Siemens SIMATIC S7-1200 CPU Family V4.7 and earlier versions have a denial of service vulnerability that can be exploited by attackers to cause a denial of service
VAR-202502-0124 CVE-2025-24811 Siemens SIMATIC S7-1200 CPU Family Denial of Service Vulnerability CVSS V2: 7.8
CVSS V3: 7.5
Severity: High
A vulnerability has been identified in SIMATIC S7-1200 CPU 1211C AC/DC/Rly (6ES7211-1BE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/DC (6ES7211-1AE40-0XB0), SIMATIC S7-1200 CPU 1211C DC/DC/Rly (6ES7211-1HE40-0XB0), SIMATIC S7-1200 CPU 1212C AC/DC/Rly (6ES7212-1BE40-0XB0), SIMATIC S7-1200 CPU 1212C DC/DC/DC (6ES7212-1AE40-0XB0), SIMATIC S7-1200 CPU 1212C DC/DC/Rly (6ES7212-1HE40-0XB0), SIMATIC S7-1200 CPU 1212FC DC/DC/DC (6ES7212-1AF40-0XB0), SIMATIC S7-1200 CPU 1212FC DC/DC/Rly (6ES7212-1HF40-0XB0), SIMATIC S7-1200 CPU 1214C AC/DC/Rly (6ES7214-1BG40-0XB0), SIMATIC S7-1200 CPU 1214C DC/DC/DC (6ES7214-1AG40-0XB0), SIMATIC S7-1200 CPU 1214C DC/DC/Rly (6ES7214-1HG40-0XB0), SIMATIC S7-1200 CPU 1214FC DC/DC/DC (6ES7214-1AF40-0XB0), SIMATIC S7-1200 CPU 1214FC DC/DC/Rly (6ES7214-1HF40-0XB0), SIMATIC S7-1200 CPU 1215C AC/DC/Rly (6ES7215-1BG40-0XB0), SIMATIC S7-1200 CPU 1215C DC/DC/DC (6ES7215-1AG40-0XB0), SIMATIC S7-1200 CPU 1215C DC/DC/Rly (6ES7215-1HG40-0XB0), SIMATIC S7-1200 CPU 1215FC DC/DC/DC (6ES7215-1AF40-0XB0), SIMATIC S7-1200 CPU 1215FC DC/DC/Rly (6ES7215-1HF40-0XB0), SIMATIC S7-1200 CPU 1217C DC/DC/DC (6ES7217-1AG40-0XB0), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-2XB0), SIPLUS S7-1200 CPU 1212 AC/DC/RLY (6AG1212-1BE40-4XB0), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-2XB0), SIPLUS S7-1200 CPU 1212 DC/DC/RLY (6AG1212-1HE40-4XB0), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-2XB0), SIPLUS S7-1200 CPU 1212C DC/DC/DC (6AG1212-1AE40-4XB0), SIPLUS S7-1200 CPU 1212C DC/DC/DC RAIL (6AG2212-1AE40-1XB0), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-2XB0), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-4XB0), SIPLUS S7-1200 CPU 1214 AC/DC/RLY (6AG1214-1BG40-5XB0), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-2XB0), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-4XB0), SIPLUS S7-1200 CPU 1214 DC/DC/DC (6AG1214-1AG40-5XB0), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-2XB0), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-4XB0), SIPLUS S7-1200 CPU 1214 DC/DC/RLY (6AG1214-1HG40-5XB0), SIPLUS S7-1200 CPU 1214C DC/DC/DC RAIL (6AG2214-1AG40-1XB0), SIPLUS S7-1200 CPU 1214FC DC/DC/DC (6AG1214-1AF40-5XB0), SIPLUS S7-1200 CPU 1214FC DC/DC/RLY (6AG1214-1HF40-5XB0), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-2XB0), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-4XB0), SIPLUS S7-1200 CPU 1215 AC/DC/RLY (6AG1215-1BG40-5XB0), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-2XB0), SIPLUS S7-1200 CPU 1215 DC/DC/DC (6AG1215-1AG40-4XB0), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-2XB0), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-4XB0), SIPLUS S7-1200 CPU 1215 DC/DC/RLY (6AG1215-1HG40-5XB0), SIPLUS S7-1200 CPU 1215C DC/DC/DC (6AG1215-1AG40-5XB0), SIPLUS S7-1200 CPU 1215FC DC/DC/DC (6AG1215-1AF40-5XB0). Affected devices do not process correctly certain special crafted packets sent to port 80/tcp, which could allow an unauthenticated attacker to cause a denial of service in the device. SIMATIC S7-1200 CPU products are designed for discrete and continuous control in industrial environments such as global manufacturing, food and beverage, and chemical industries. Siemens SIMATIC S7-1200 CPU Family V4.7 and earlier versions have a denial of service vulnerability that can be exploited by attackers to cause a denial of service
VAR-202502-0199 CVE-2024-53651 Siemens SIPROTEC 5 sensitive information plaintext storage vulnerability CVSS V2: 6.1
CVSS V3: 4.6
Severity: Medium
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions), SIPROTEC 5 6MD85 (CP200) (All versions), SIPROTEC 5 6MD85 (CP300) (All versions), SIPROTEC 5 6MD86 (CP200) (All versions), SIPROTEC 5 6MD86 (CP300) (All versions), SIPROTEC 5 6MD89 (CP300) (All versions), SIPROTEC 5 6MU85 (CP300) (All versions), SIPROTEC 5 7KE85 (CP200) (All versions), SIPROTEC 5 7KE85 (CP300) (All versions), SIPROTEC 5 7SA82 (CP100) (All versions), SIPROTEC 5 7SA82 (CP150) (All versions), SIPROTEC 5 7SA86 (CP200) (All versions), SIPROTEC 5 7SA86 (CP300) (All versions), SIPROTEC 5 7SA87 (CP200) (All versions), SIPROTEC 5 7SA87 (CP300) (All versions), SIPROTEC 5 7SD82 (CP100) (All versions), SIPROTEC 5 7SD82 (CP150) (All versions), SIPROTEC 5 7SD86 (CP200) (All versions), SIPROTEC 5 7SD86 (CP300) (All versions), SIPROTEC 5 7SD87 (CP200) (All versions), SIPROTEC 5 7SD87 (CP300) (All versions), SIPROTEC 5 7SJ81 (CP100) (All versions), SIPROTEC 5 7SJ81 (CP150) (All versions), SIPROTEC 5 7SJ82 (CP100) (All versions), SIPROTEC 5 7SJ82 (CP150) (All versions), SIPROTEC 5 7SJ85 (CP200) (All versions), SIPROTEC 5 7SJ85 (CP300) (All versions), SIPROTEC 5 7SJ86 (CP200) (All versions), SIPROTEC 5 7SJ86 (CP300) (All versions), SIPROTEC 5 7SK82 (CP100) (All versions), SIPROTEC 5 7SK82 (CP150) (All versions), SIPROTEC 5 7SK85 (CP200) (All versions), SIPROTEC 5 7SK85 (CP300) (All versions), SIPROTEC 5 7SL82 (CP100) (All versions), SIPROTEC 5 7SL82 (CP150) (All versions), SIPROTEC 5 7SL86 (CP200) (All versions), SIPROTEC 5 7SL86 (CP300) (All versions), SIPROTEC 5 7SL87 (CP200) (All versions), SIPROTEC 5 7SL87 (CP300) (All versions), SIPROTEC 5 7SS85 (CP200) (All versions), SIPROTEC 5 7SS85 (CP300) (All versions), SIPROTEC 5 7ST85 (CP200) (All versions), SIPROTEC 5 7ST85 (CP300) (All versions), SIPROTEC 5 7ST86 (CP300) (All versions), SIPROTEC 5 7SX82 (CP150) (All versions), SIPROTEC 5 7SX85 (CP300) (All versions), SIPROTEC 5 7SY82 (CP150) (All versions), SIPROTEC 5 7UM85 (CP300) (All versions), SIPROTEC 5 7UT82 (CP100) (All versions), SIPROTEC 5 7UT82 (CP150) (All versions), SIPROTEC 5 7UT85 (CP200) (All versions), SIPROTEC 5 7UT85 (CP300) (All versions), SIPROTEC 5 7UT86 (CP200) (All versions), SIPROTEC 5 7UT86 (CP300) (All versions), SIPROTEC 5 7UT87 (CP200) (All versions), SIPROTEC 5 7UT87 (CP300) (All versions), SIPROTEC 5 7VE85 (CP300) (All versions), SIPROTEC 5 7VK87 (CP200) (All versions), SIPROTEC 5 7VK87 (CP300) (All versions), SIPROTEC 5 7VU85 (CP300) (All versions), SIPROTEC 5 Compact 7SX800 (CP050) (All versions). Affected devices do not encrypt certain data within the on-board flash storage on their PCB. This could allow an attacker with physical access to read the entire filesystem of the device. SIPROTEC 5 devices provide a range of integrated protection, control, measurement and automation functions for substations and other application areas. Siemens SIPROTEC 5 has a sensitive information plaintext storage vulnerability
VAR-202502-0219 CVE-2024-45386 Siemens Product Session Expiration Insufficient Vulnerability CVSS V2: 10.0
CVSS V3: 8.8
Severity: High
A vulnerability has been identified in SIMATIC PCS neo V4.0 (All versions), SIMATIC PCS neo V4.1 (All versions < V4.1 Update 2), SIMATIC PCS neo V5.0 (All versions < V5.0 Update 1), SIMOCODE ES V19 (All versions < V19 Update 1), SIRIUS Safety ES V19 (TIA Portal) (All versions < V19 Update 1), SIRIUS Soft Starter ES V19 (TIA Portal) (All versions < V19 Update 1), TIA Administrator (All versions < V3.0.4). Affected products do not correctly invalidate user sessions upon user logout. This could allow a remote unauthenticated attacker, who has obtained the session token by other means, to re-use a legitimate user's session even after logout. SIMATIC PCS neo is a new generation of distributed control system (DCS) launched by Siemens. It is designed based on the Web platform and HTML5 technology, specially designed for process industry, and supports multi-user collaborative work and digital management. TIA Administrator is a management tool in Siemens Industrial Automation Software Suite, mainly used for centralized management and maintenance of TIA Portal projects. Totally Integrated Automation Portal (TIA Portal) is a fully integrated automation software platform launched by Siemens, which aims to simplify the automation project development process through a unified engineering environment. Siemens SIMATIC PCS neo, TIA Administrator, and Totally Integrated Automation Portal have insufficient session expiration vulnerabilities
VAR-202502-0123 CVE-2023-37482 Siemens Multiple SIMATIC Products Web Server User Enumeration Vulnerability CVSS V2: 5.0
CVSS V3: 5.3
Severity: Medium
The login functionality of the web server in affected devices does not normalize the response times of login attempts. An unauthenticated remote attacker could exploit this side-channel information to distinguish between valid and invalid usernames. SIMATIC Drive Controllers are designed for the automation of production machines and combine the functionality of the SIMATIC S7-1500 CPU and SINAMICS S120 drive control. The SIMATIC ET 200SP Open Controller is a PC-based version of the SIMATIC S7-1500 controller, including optional visualization and central I/O combinations in one compact device. The SIMATIC S7-1200 CPU products are designed for discrete and continuous control in industrial environments such as global manufacturing, food and beverage, and chemical industries. The SIMATIC S7-1200 CPU products are designed for discrete and continuous control in industrial environments such as global manufacturing, food and beverage, and chemical industries. The SIMATIC S7-1500 CPU products are designed for discrete and continuous control in industrial environments such as global manufacturing, food and beverage, and chemical industries. The SIMATIC S7-1500 Software Controller is the SIMATIC software controller for PC-based automation solutions. SIMATIC S7-PLCSIM Advanced simulates S7-1200, S7-1500 and some other PLC derivatives. Includes full network access to simulate PLCs, even in virtualized environments
VAR-202502-0246 CVE-2024-53977 Siemens ModelSim and Questa Local Code Execution Vulnerabilities CVSS V2: 6.0
CVSS V3: 6.7
Severity: Medium
A vulnerability has been identified in ModelSim (All versions < V2025.1), Questa (All versions < V2025.1). An example setup script contained in affected applications allows a specific executable file to be loaded from the current working directory. This could allow an authenticated local attacker to inject arbitrary code and escalate privileges in installations where administrators or processes with elevated privileges launch the script from a user-writable directory. ModelSim is an industry-leading hardware description language (HDL) simulation tool developed by Mentor Graphics (now a Siemens company), mainly used for verification and debugging of digital circuit designs. Questa is an intelligent verification solution launched by Siemens, which aims to optimize the integrated circuit (IC) verification process through artificial intelligence (AI) technology, improve production efficiency and meet complex design challenges
VAR-202502-0121 CVE-2024-54090 Siemens APOGEE PXC Series and TALON TC Series (BACnet) Out-of-Bounds Read Vulnerability CVSS V2: 5.4
CVSS V3: 5.9
Severity: Medium
A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices contain an out-of-bounds read in the memory dump function. This could allow an attacker with Medium (MED) or higher privileges to cause the device to enter an insecure cold start state. The direct digital controller (DDC) in the Siemens APOGEE PXC Series building automation system is designed for small and medium-sized buildings and has modular expansion capabilities and intelligent control functions. TALON TC Series (BACnet) is a building management system that is mainly used to monitor and control building equipment. The system implements remote management functions through the BACnet protocol and supports real-time monitoring and adjustment of environmental parameters (such as temperature, humidity, etc.) in the building
VAR-202502-0237 CVE-2025-23403 Siemens SIMATIC IPC DiagBase and SIMATIC IPC DiagMonitor Weak Registry Privilege Escalation Vulnerability CVSS V2: 6.2
CVSS V3: 7.0
Severity: High
A vulnerability has been identified in SIMATIC IPC DiagBase (All versions), SIMATIC IPC DiagMonitor (All versions). The affected device do not properly restrict the user permission for the registry key. This could allow an authenticated attacker to load vulnerable drivers into the system leading to privilege escalation or bypassing endpoint protection and other security measures. SIMATIC IPC DiagBase is a system monitoring and troubleshooting software that identifies any potential faults on SIMATIC IPCs at an early stage and helps to avoid or reduce system downtime. SIMATIC IPC DiagMonitor monitors, reports, visualizes and logs the system status of SIMATIC IPCs. It communicates with other systems and reacts when events occur
VAR-202502-2686 No CVE Shanghai Boda Data Communication Co., Ltd.'s Internet behavior management and auditing have information leakage vulnerabilities CVSS V2: 2.1
CVSS V3: -
Severity: LOW
Shanghai Boda Data Communication Co., Ltd. is China's first generation professional IP network product and solution provider. Shanghai Boda Data Communication Co., Ltd. has an information leakage vulnerability in its online behavior management and auditing, which can be exploited by attackers to obtain sensitive information.
VAR-202502-0122 CVE-2024-54089 Siemens APOGEE PXC Series and TALON TC Series (BACnet) Encryption Issue Vulnerability CVSS V2: 7.8
CVSS V3: 7.5
Severity: High
A vulnerability has been identified in APOGEE PXC Series (BACnet) (All versions), APOGEE PXC Series (P2 Ethernet) (All versions), TALON TC Series (BACnet) (All versions). Affected devices contain a weak encryption mechanism based on a hard-coded key. This could allow an attacker to guess or decrypt the password from the cyphertext. The direct digital controller (DDC) in the Siemens APOGEE PXC Series building automation system is designed for small and medium-sized buildings and has modular expansion capabilities and intelligent control functions. TALON TC Series (BACnet) is a building management system that is mainly used to monitor and control building equipment. The system implements remote management functions through the BACnet protocol and supports real-time monitoring and adjustment of environmental parameters (such as temperature, humidity, etc.) in the building
VAR-202502-0263 CVE-2024-54015 Siemens SIPROTEC 5 Devices Information Disclosure Vulnerability CVSS V2: 7.8
CVSS V3: 7.5
Severity: High
A vulnerability has been identified in SIPROTEC 5 6MD84 (CP300) (All versions < V9.90), SIPROTEC 5 6MD85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 6MD89 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 6MU85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7KE85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7SA82 (CP150) (All versions < V9.90), SIPROTEC 5 7SA86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SA87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.90), SIPROTEC 5 7SD86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SD87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.90), SIPROTEC 5 7SJ85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SJ86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SK82 (CP150) (All versions < V9.90), SIPROTEC 5 7SK85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.90), SIPROTEC 5 7SL86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SL87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SS85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7ST85 (CP300) (All versions >= V8.80 < V10.0), SIPROTEC 5 7ST85 (CP300) V9.6x (All versions < V9.68), SIPROTEC 5 7ST86 (CP300) (All versions < V10.0), SIPROTEC 5 7ST86 (CP300) V9.8x (All versions < V9.83), SIPROTEC 5 7SX82 (CP150) (All versions < V9.90), SIPROTEC 5 7SX85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7SY82 (CP150) (All versions < V9.90), SIPROTEC 5 7UM85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.90), SIPROTEC 5 7UT85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT86 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7UT87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VE85 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VK87 (CP300) (All versions >= V8.80 < V9.90), SIPROTEC 5 7VU85 (CP300) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) (All versions < V9.90), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 2) V9.8 (All versions < V9.83), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions >= V8.80 < V9.90), SIPROTEC 5 Communication Module ETH-BD-2FO V9.6 (All versions < V9.68), SIPROTEC 5 Communication Module ETH-BD-2FO V9.8 (All versions < V9.83), SIPROTEC 5 Compact 7SX800 (CP050) (All versions >= V9.50 < V9.90). Affected devices do not properly validate SNMP GET requests. This could allow an unauthenticated, remote attacker to retrieve sensitive information of the affected devices with SNMPv2 GET requests using default credentials. SIPROTEC 5 Devices provide a range of integrated protection, control, measurement and automation functions for substations and other application areas
VAR-202502-1335 CVE-2024-46437 Shenzhen Tenda Technology Co.,Ltd.  of  w18e  Information disclosure vulnerability in firmware CVSS V2: 6.1
CVSS V3: 6.5
Severity: MEDIUM
A sensitive information disclosure vulnerability in the Tenda W18E V16.01.0.8(1625) web management portal allows an unauthenticated remote attacker to retrieve sensitive configuration information, including WiFi SSID, WiFi password, and base64-encoded administrator credentials, by sending a specially crafted HTTP POST request to the getQuickCfgWifiAndLogin function, bypassing authentication checks. Shenzhen Tenda Technology Co.,Ltd. of w18e Firmware has an information disclosure vulnerability.Information may be obtained. Tenda W18E version 16.01.0.8(1625) has an information leakage vulnerability. The vulnerability is caused by the application's insufficient protection of sensitive information. Attackers can exploit this vulnerability to retrieve sensitive configuration information