VARIoT IoT vulnerabilities database
| VAR-202212-2614 | CVE-2022-46562 | D-Link DIR-882 DIR882A1_FW130B06 Out-of-bounds write vulnerability in |
CVSS V2: 8.3 CVSS V3: 7.2 Severity: HIGH |
D-Link DIR-882 DIR882A1_FW130B06, DIR-878 DIR_878_FW1.30B08 was discovered to contain a stack overflow via the PSK parameter in the SetQuickVPNSettings module. D-Link DIR-882 DIR882A1_FW130B06 Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. D-Link DIR-882 is a wireless router made by China D-Link Company.
There is a security vulnerability in D-Link DIR-882 DIR882A1_FW130B06. No detailed vulnerability details were provided at this time
| VAR-202212-1929 | CVE-2022-33324 | Made by Mitsubishi Electric MELSEC iQ-R Series and iQ-L series, MELIPC Of the series Ethernet port Improper Resource Shutdown and Release Vulnerability in |
CVSS V2: - CVSS V3: 7.5 Severity: HIGH |
Improper Resource Shutdown or Release vulnerability in Mitsubishi Electric Corporation MELSEC iQ-R Series R00/01/02CPU Firmware versions "32" and prior, Mitsubishi Electric Corporation MELSEC iQ-R Series R04/08/16/32/120(EN)CPU Firmware versions "65" and prior, Mitsubishi Electric Corporation MELSEC iQ-R Series R08/16/32/120SFCPU Firmware versions "29" and prior, Mitsubishi Electric Corporation MELSEC iQ-R Series R08/16/32/120PSFCPU Firmware versions "08" and prior, Mitsubishi Electric Corporation MELSEC iQ-R Series R12CCPU-V Firmware versions "17" and prior, Mitsubishi Electric Corporation MELSEC iQ-L Series L04/08/16/32HCPU Firmware versions "05" and prior and Mitsubishi Electric Corporation MELIPC Series MI5122-VW Firmware versions "07" and prior allows a remote unauthenticated attacker to cause a Denial of Service condition in Ethernet communication on the module by sending specially crafted packets. A system reset of the module is required for recovery. This vulnerability information is provided by the developer for the purpose of disseminating it to product users. JPCERT/CC Report to JPCERT/CC Coordinated with the developer.When a packet crafted by a remote third party is received, the product Ethernet Communication is a denial of service ( DoS ). In addition, reset of the product concerned is necessary for restoration
| VAR-202212-2066 | CVE-2022-3156 | Rockwell Automation Studio 5000 Logix Designer Access Control Error Vulnerability |
CVSS V2: 6.8 CVSS V3: 7.8 Severity: HIGH |
A remote code execution vulnerability exists in Rockwell Automation Studio 5000 Logix Emulate software. Users are granted elevated permissions on certain product services when the software is installed. Due to
this misconfiguration, a malicious user could potentially achieve remote code execution on the targeted software. It is used to build programs for PLCs. No detailed vulnerability details are currently provided
| VAR-202212-1898 | CVE-2022-22184 | Juniper Networks Junos OS and Junos OS Evolved Input verification vulnerability in |
CVSS V2: - CVSS V3: 7.5 Severity: HIGH |
An Improper Input Validation vulnerability in the Routing Protocol Daemon (rpd) of Juniper Networks Junos OS and Junos OS Evolved allows an unauthenticated network-based attacker to cause a Denial of Service (DoS). If a BGP update message is received over an established BGP session, and that message contains a specific, optional transitive attribute, this session will be torn down with an update message error. This issue cannot propagate beyond an affected system as the processing error occurs as soon as the update is received. This issue is exploitable remotely as the respective attribute will propagate through unaffected systems and intermediate AS (if any). Continuous receipt of a BGP update containing this attribute will create a sustained Denial of Service (DoS) condition. Since this issue only affects 22.3R1, Juniper strongly encourages customers to move to 22.3R1-S1. Juniper SIRT felt that the need to promptly warn customers about this issue affecting the 22.3R1 versions of Junos OS and Junos OS Evolved warranted an Out of Cycle JSA. This issue affects: Juniper Networks Junos OS version 22.3R1. Juniper Networks Junos OS Evolved version 22.3R1-EVO. This issue does not affect: Juniper Networks Junos OS versions prior to 22.3R1. Juniper Networks Junos OS Evolved versions prior to 22.3R1-EVO
| VAR-202212-1811 | CVE-2022-3087 | Fuji Electric Tellus Lite V-Simulator 6 X1 File Parsing Out-Of-Bounds Write Remote Code Execution Vulnerability |
CVSS V2: - CVSS V3: 7.8 Severity: HIGH |
Fuji Electric Tellus Lite V-Simulator versions 4.0.12.0 and prior are vulnerable to an out-of-bounds write which may allow an attacker to execute arbitrary code. (DoS) It may be in a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of X1 files in the V-Simulator 6 application. The issue results from the lack of proper validation of user-supplied data, which can result in a write past the end of an allocated data structure. An attacker can leverage this vulnerability to execute code in the context of the current process
| VAR-202212-1833 | CVE-2022-46533 | Shenzhen Tenda Technology Co.,Ltd. of f1203 Classic buffer overflow vulnerability in firmware |
CVSS V2: - CVSS V3: 7.5 Severity: HIGH |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the limitSpeed parameter at /goform/SetClientState. Shenzhen Tenda Technology Co.,Ltd. of f1203 Firmware has a classic buffer overflow vulnerability.Service operation interruption (DoS) It may be in a state
| VAR-202212-1818 | CVE-2022-46537 | Shenzhen Tenda Technology Co.,Ltd. of f1203 Classic buffer overflow vulnerability in firmware |
CVSS V2: - CVSS V3: 7.5 Severity: HIGH |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the security parameter at /goform/WifiBasicSet. Shenzhen Tenda Technology Co.,Ltd. of f1203 Firmware has a classic buffer overflow vulnerability.Service operation interruption (DoS) It may be in a state
| VAR-202212-1846 | CVE-2022-46532 | Shenzhen Tenda Technology Co.,Ltd. of f1203 Classic buffer overflow vulnerability in firmware |
CVSS V2: - CVSS V3: 7.5 Severity: HIGH |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the deviceMac parameter at /goform/addWifiMacFilter. Shenzhen Tenda Technology Co.,Ltd. of f1203 Firmware has a classic buffer overflow vulnerability.Service operation interruption (DoS) It may be in a state
| VAR-202212-1848 | CVE-2022-46548 | Shenzhen Tenda Technology Co.,Ltd. of f1203 Classic buffer overflow vulnerability in firmware |
CVSS V2: - CVSS V3: 7.5 Severity: HIGH |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/DhcpListClient. Shenzhen Tenda Technology Co.,Ltd. of f1203 Firmware has a classic buffer overflow vulnerability.Service operation interruption (DoS) It may be in a state
| VAR-202212-1847 | CVE-2022-46544 | Shenzhen Tenda Technology Co.,Ltd. of f1203 Classic buffer overflow vulnerability in firmware |
CVSS V2: - CVSS V3: 7.5 Severity: HIGH |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the cmdinput parameter at /goform/exeCommand. Shenzhen Tenda Technology Co.,Ltd. of f1203 Firmware has a classic buffer overflow vulnerability.Service operation interruption (DoS) It may be in a state
| VAR-202207-0996 | CVE-2022-46422 | Netgear WNR2000 Vulnerability in |
CVSS V2: 4.9 CVSS V3: 4.8 Severity: MEDIUM |
An issue in Netgear WNR2000 v1 1.2.3.7 and earlier allows authenticated attackers to cause a Denial of Service (DoS) via uploading a crafted firmware image during the firmware update process. Netgear WNR2000 Exists in unspecified vulnerabilities.Service operation interruption (DoS) It may be in a state. NETGEAR WNR2000v1 Router is a single-band wireless router based on the IEEE 802.11n standard.
NETGEAR WNR2000v1 Router has a denial of service vulnerability
| VAR-202212-1802 | CVE-2022-46540 | Shenzhen Tenda Technology Co.,Ltd. of f1203 Classic buffer overflow vulnerability in firmware |
CVSS V2: - CVSS V3: 7.5 Severity: HIGH |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the entrys parameter at /goform/addressNat. Shenzhen Tenda Technology Co.,Ltd. of f1203 Firmware has a classic buffer overflow vulnerability.Service operation interruption (DoS) It may be in a state
| VAR-202212-1861 | CVE-2022-46550 | Shenzhen Tenda Technology Co.,Ltd. of f1203 Classic buffer overflow vulnerability in firmware |
CVSS V2: - CVSS V3: 7.5 Severity: HIGH |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the urls parameter at /goform/saveParentControlInfo. Shenzhen Tenda Technology Co.,Ltd. of f1203 Firmware has a classic buffer overflow vulnerability.Service operation interruption (DoS) It may be in a state
| VAR-202212-1897 | CVE-2022-46541 | Shenzhen Tenda Technology Co.,Ltd. of f1203 Classic buffer overflow vulnerability in firmware |
CVSS V2: - CVSS V3: 7.5 Severity: HIGH |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the ssid parameter at /goform/fast_setting_wifi_set. Shenzhen Tenda Technology Co.,Ltd. of f1203 Firmware has a classic buffer overflow vulnerability.Service operation interruption (DoS) It may be in a state
| VAR-202212-1812 | CVE-2022-3085 | Fuji Electric Tellus Lite V-Simulator Stack-based buffer overflow vulnerability in |
CVSS V2: 7.2 CVSS V3: 7.8 Severity: HIGH |
Fuji Electric Tellus Lite V-Simulator versions 4.0.12.0 and prior are vulnerable to a stack-based buffer overflow which may allow an attacker to execute arbitrary code. (DoS) It may be in a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of X1 files in the V-Simulator 6 application. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process. It is primarily used to collect real-time data from devices such as PLCs (Programmable Logic Controllers), temperature controllers, and inverters
| VAR-202212-1756 | CVE-2022-45665 | Shenzhen Tenda Technology Co.,Ltd. of i22 Classic buffer overflow vulnerability in firmware |
CVSS V2: 7.8 CVSS V3: 7.5 Severity: HIGH |
Tenda i22 V1.0.0.3(4687) was discovered to contain a buffer overflow via the funcpara1 parameter in the formSetCfm function. Shenzhen Tenda Technology Co.,Ltd. of i22 Firmware has a classic buffer overflow vulnerability.Service operation interruption (DoS) It may be in a state. A remote attacker can use this vulnerability to submit a special request, execute arbitrary code in the system context or crash the application
| VAR-202212-1835 | CVE-2022-46547 | Shenzhen Tenda Technology Co.,Ltd. of f1203 Classic buffer overflow vulnerability in firmware |
CVSS V2: - CVSS V3: 7.5 Severity: HIGH |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/VirtualSer. Shenzhen Tenda Technology Co.,Ltd. of f1203 Firmware has a classic buffer overflow vulnerability.Service operation interruption (DoS) It may be in a state
| VAR-202212-2145 | CVE-2022-46912 | TP-Link TL-WR841N and TL-WA841ND V7 Vulnerability in |
CVSS V2: - CVSS V3: 8.8 Severity: HIGH |
An issue in the firmware update process of TP-Link TL-WR841N / TL-WA841ND V7 3.13.9 and earlier allows attackers to execute arbitrary code or cause a Denial of Service (DoS) via uploading a crafted firmware image. TP-Link TL-WR841N and TL-WA841ND V7 Exists in unspecified vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
| VAR-202212-1860 | CVE-2022-46542 | Shenzhen Tenda Technology Co.,Ltd. of f1203 Classic buffer overflow vulnerability in firmware |
CVSS V2: - CVSS V3: 7.5 Severity: HIGH |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the page parameter at /goform/addressNat. Shenzhen Tenda Technology Co.,Ltd. of f1203 Firmware has a classic buffer overflow vulnerability.Service operation interruption (DoS) It may be in a state
| VAR-202212-1797 | CVE-2022-46531 | Shenzhen Tenda Technology Co.,Ltd. of f1203 Classic buffer overflow vulnerability in firmware |
CVSS V2: - CVSS V3: 7.5 Severity: HIGH |
Tenda F1203 V2.0.1.6 was discovered to contain a buffer overflow via the deviceId parameter at /goform/addWifiMacFilter. Shenzhen Tenda Technology Co.,Ltd. of f1203 Firmware has a classic buffer overflow vulnerability.Service operation interruption (DoS) It may be in a state