VAR-202303-1330 CVE-2023-25281 D-Link Systems, Inc.  of  DIR820LA1  Out-of-bounds write vulnerability in firmware CVSS V2: -
CVSS V3: 7.5
Severity: HIGH
A stack overflow vulnerability exists in pingV4Msg component in D-Link DIR820LA1_FW105B03, allows attackers to cause a denial of service via the nextPage parameter to ping.ccp. D-Link Systems, Inc. of DIR820LA1 An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state
VAR-202303-1392 CVE-2023-25280 D-Link Systems, Inc.  of  DIR820LA1  in the firmware  OS  Command injection vulnerability CVSS V2: -
CVSS V3: 9.8
Severity: CRITICAL
OS Command injection vulnerability in D-Link DIR820LA1_FW105B03 allows attackers to escalate privileges to root via a crafted payload with the ping_addr parameter to ping.ccp. D-Link Systems, Inc. (DoS) It may be in a state
VAR-202303-1424 CVE-2023-27984 Schneider Electric IGSS Data Server Input Validation Error Vulnerability CVSS V2: 7.2
CVSS V3: 8.8
Severity: HIGH
A CWE-20: Improper Input Validation vulnerability exists in Custom Reports that could cause a macro to be executed, potentially leading to remote code execution when a user opens a malicious report file planted by an attacker. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior). Schneider Electric of custom reports , IGSS Dashboard (DashBoard.exe) , igss data server There is an input validation vulnerability in.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric IGSS. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the openReport function. The issue results from the lack of proper input validation. An attacker can leverage this vulnerability to execute code in the context of the current user. Schneider Electric IGSS Data Server is a data server of an interactive graphic Scada system of French Schneider Electric (Schneider Electric)
VAR-202303-1538 CVE-2023-27977 plural  Schneider Electric  Insufficient Validation of Data Trust in Products Vulnerability CVSS V2: 6.4
CVSS V3: 5.3
Severity: MEDIUM
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause access to delete files in the IGSS project report directory, this could lead to loss of data when an attacker sends specific crafted messages to the Data Server TCP port. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior). This vulnerability allows remote attackers to create a denial-of-service condition on affected installations of Schneider Electric IGSS. Authentication is not required to exploit this vulnerability.The specific flaw exists within the IGSSdataServer process, which listens on TCP port 12401 by default. The issue results from the exposure of a dangerous function. An attacker can leverage this vulnerability to create a denial-of-service condition on the system
VAR-202303-1372 CVE-2023-27978 plural  Schneider Electric  Product untrusted data deserialization vulnerability CVSS V2: 7.2
CVSS V3: 7.8
Severity: HIGH
A CWE-502: Deserialization of Untrusted Data vulnerability exists in the Dashboard module that could cause an interpretation of malicious payload data, potentially leading to remote code execution when an attacker gets the user to open a malicious file. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior). Schneider Electric of custom reports , IGSS Dashboard (DashBoard.exe) , igss data server There is a vulnerability in deserialization of untrusted data.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric IGSS. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the DashFiles class. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to execute code in the context of the current user. Schneider Electric IGSS Data Server is a data server of an interactive graphic Scada system of French Schneider Electric (Schneider Electric)
VAR-202303-1298 CVE-2023-27982 plural  Schneider Electric  Insufficient Validation of Data Trust in Products Vulnerability CVSS V2: 10.0
CVSS V3: 8.8
Severity: HIGH
A CWE-345: Insufficient Verification of Data Authenticity vulnerability exists in the Data Server that could cause manipulation of dashboard files in the IGSS project report directory, when an attacker sends specific crafted messages to the Data Server TCP port, this could lead to remote code execution when a victim eventually opens a malicious dashboard file. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior). Schneider Electric of custom reports , IGSS Dashboard (DashBoard.exe) , igss data server Exists in an inadequate validation of data reliability vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric IGSS. Authentication is not required to exploit this vulnerability.The specific flaw exists within the IGSSdataServer process, which listens on TCP port 12401 by default. The issue results from the exposure of a dangerous function. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current user. Schneider Electric IGSS Data Server is a data server of an interactive graphic Scada system of French Schneider Electric (Schneider Electric). Schneider Electric IGSS Data Server has a data forgery vulnerability
VAR-202303-1297 CVE-2023-27980 plural  Schneider Electric  Vulnerability related to lack of authentication for critical functions in the product CVSS V2: 10.0
CVSS V3: 8.8
Severity: HIGH
A CWE-306: Missing Authentication for Critical Function vulnerability exists in the Data Server TCP interface that could allow the creation of a malicious report file in the IGSS project report directory, this could lead to remote code execution when a victim eventually opens the report. Affected Products: IGSS Data Server(IGSSdataServer.exe)(V16.0.0.23040 and prior), IGSS Dashboard(DashBoard.exe)(V16.0.0.23040 and prior), Custom Reports(RMS16.dll)(V16.0.0.23040 and prior). Schneider Electric of custom reports , IGSS Dashboard (DashBoard.exe) , igss data server There is a vulnerability in the lack of authentication for critical features.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Schneider Electric IGSS. Authentication is not required to exploit this vulnerability.The specific flaw exists within the IGSSdataServer process, which listens on TCP port 12401 by default. The issue results from the exposure of a dangerous function. An attacker can leverage this in conjunction with other vulnerabilities to execute arbitrary code in the context of the current user. Schneider Electric IGSS Data Server is a data server of an interactive graphic Scada system of French Schneider Electric (Schneider Electric)
VAR-202303-1243 CVE-2023-27239 Shenzhen Tenda Technology Co.,Ltd.  of  AX3  Out-of-bounds write vulnerability in firmware CVSS V2: 10.0
CVSS V3: 9.8
Severity: CRITICAL
Tenda AX3 V16.03.12.11 was discovered to contain a stack overflow via the shareSpeed parameter at /goform/WifiGuestSet. Shenzhen Tenda Technology Co.,Ltd. of AX3 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda Ax3 is an Ax1800 Gigabit port dual-band Wifi 6 wireless router from the Chinese company Tenda. The vulnerability is caused by the fact that the shareSpeed parameter in /goform/WifiGuestSet fails to verify user input correctly. Attackers can exploit this vulnerability to cause remote code execution or denial of service
VAR-202303-1259 CVE-2023-25282 D-Link Systems, Inc.  of  DIR-820L  Out-of-bounds write vulnerability in firmware CVSS V2: -
CVSS V3: 6.5
Severity: MEDIUM
A heap overflow vulnerability in D-Link DIR820LA1_FW106B02 allows attackers to cause a denial of service via the config.log_to_syslog and log_opt_dropPackets parameters to mydlink_api.ccp. D-Link Systems, Inc. of DIR-820L The firmware contains an out-of-bounds write vulnerability.Service operation interruption (DoS) It may be in a state
VAR-202303-1268 CVE-2023-1389 TP-LINK Technologies  of  archer ax21  Command injection vulnerability in firmware CVSS V2: 10.0
CVSS V3: 8.8
Severity: HIGH
TP-Link Archer AX21 (AX1800) firmware versions before 1.1.4 Build 20230219 contained a command injection vulnerability in the country form of the /cgi-bin/luci;stok=/locale endpoint on the web management interface. Specifically, the country parameter of the write operation was not sanitized before being used in a call to popen(), allowing an unauthenticated attacker to inject commands, which would be run as root, with a simple POST request. (DoS) It may be in a state. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of TP-Link Archer AX21 routers. Authentication is not required to exploit this vulnerability.The specific flaw exists within the merge_country_config function. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute arbitrary code in the context of root. TP-Link Archer AX21 AX1800 is a TP-Link WIFI6 router. There is a command injection vulnerability in TP-Link Archer AX21 AX1800. The vulnerability comes from not filtering user input
VAR-202303-1196 CVE-2023-27240 Shenzhen Tenda Technology Co.,Ltd.  of  AX3  Command injection vulnerability in firmware CVSS V2: 10.0
CVSS V3: 9.8
Severity: CRITICAL
Tenda AX3 V16.03.12.11 was discovered to contain a command injection vulnerability via the lanip parameter at /goform/AdvSetLanip. Shenzhen Tenda Technology Co.,Ltd. of AX3 Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Tenda Ax3 is an Ax1800 Gigabit port dual-band Wifi 6 wireless router from the Chinese company Tenda. The vulnerability stems from the fact that the lanip parameter of /goform/AdvSetLanip fails to properly filter special characters and commands in the construction command. Attackers can use this vulnerability to execute arbitrary commands
VAR-202303-1193 CVE-2023-24229 DrayTek Corporation  of  Vigor2960  Command injection vulnerability in firmware CVSS V2: -
CVSS V3: 7.8
Severity: HIGH
DrayTek Vigor2960 v1.5.1.4 allows an authenticated attacker with network access to the web management interface to inject operating system commands via the mainfunction.cgi 'parameter' parameter. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. DrayTek Corporation of Vigor2960 Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
VAR-202303-1296 CVE-2023-27333 TP-LINK Technologies  of  archer ax21  Stack-based buffer overflow vulnerability in firmware CVSS V2: -
CVSS V3: 6.8
Severity: MEDIUM
TP-Link Archer AX21 tmpServer Command 0x422 Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of TP-Link Archer AX21 routers. Authentication is required to exploit this vulnerability. The specific flaw exists within the handling of command 0x422 provided to the tmpServer service. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-19905. (DoS) It may be in a state
VAR-202303-1316 CVE-2023-0598 GE iFIX Code injection vulnerability CVSS V2: -
CVSS V3: 9.8
Severity: CRITICAL
GE Digital Proficy iFIX 2022, GE Digital Proficy iFIX v6.1, and GE Digital Proficy iFIX v6.5 are vulnerable to code injection, which may allow an attacker to insert malicious configuration files in the expected web server execution path and gain full control of the HMI software
VAR-202303-1251 CVE-2023-27332 TP-LINK Technologies  of  archer ax21  Stack-based buffer overflow vulnerability in firmware CVSS V2: 8.3
CVSS V3: 8.8
Severity: HIGH
TP-Link Archer AX21 tdpServer Logging Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of TP-Link Archer AX21 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the logging functionality of the tdpServer program, which listens on UDP port 20002. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-19898. (DoS) It may be in a state. TP-LINK Archer AX21 is a wireless router from China's TP-LINK company
VAR-202303-1178 CVE-2023-28338 of netgear  RAX30  Unlimited or Throttling Resource Allocation Vulnerability in Firmware CVSS V2: 7.8
CVSS V3: 7.5
Severity: HIGH
Any request send to a Netgear Nighthawk Wifi6 Router (RAX30)'s web service containing a “Content-Type” of “multipartboundary=” will result in the request body being written to “/tmp/mulipartFile” on the device itself. A sufficiently large file will cause device resources to be exhausted, resulting in the device becoming unusable until it is rebooted. of netgear RAX30 A vulnerability exists in the firmware regarding resource allocation without limits or throttling.Service operation interruption (DoS) It may be in a state. NETGEAR RAX30 is a dual-band wireless router from NETGEAR. NETGEAR RAX30 has a denial of service vulnerability. The vulnerability stems from the improper handling of a large number of message requests
VAR-202303-1219 CVE-2023-0021 SAP  of  SAP NetWeaver  Cross-site scripting vulnerability in CVSS V2: -
CVSS V3: 6.1
Severity: MEDIUM
Due to insufficient encoding of user input, SAP NetWeaver - versions 700, 701, 702, 731, 740, 750, allows an unauthenticated attacker to inject code that may expose sensitive data like user ID and password, which could lead to reflected Cross-Site scripting. These endpoints are normally exposed over the network and successful exploitation can partially impact confidentiality of the application. SAP of SAP NetWeaver Exists in a cross-site scripting vulnerability.Information may be obtained and information may be tampered with
VAR-202303-0929 CVE-2023-27589 Minio Inc.  of  Minio  Vulnerability in CVSS V2: -
CVSS V3: 6.5
Severity: MEDIUM
Minio is a Multi-Cloud Object Storage framework. Starting with RELEASE.2020-12-23T02-24-12Z and prior to RELEASE.2023-03-13T19-46-17Z, a user with `consoleAdmin` permissions can potentially create a user that matches the root credential `accessKey`. Once this user is created successfully, the root credential ceases to work appropriately. The issue is patched in RELEASE.2023-03-13T19-46-17Z. There are ways to work around this via adding higher privileges to the disabled root user via `mc admin policy set`. Minio Inc. of Minio Exists in unspecified vulnerabilities.Information is tampered with and service operation is interrupted (DoS) It may be in a state
VAR-202303-0935 CVE-2023-1327 of netgear  RAX30  Authentication vulnerability in firmware CVSS V2: 10.0
CVSS V3: 9.8
Severity: CRITICAL
Netgear RAX30 (AX2400), prior to version 1.0.6.74, was affected by an authentication bypass vulnerability, allowing an unauthenticated attacker to gain administrative access to the device's web management interface by resetting the admin password. of netgear RAX30 An authentication vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. NETGEAR RAX30 (AX2400) is a wireless router that supports WiFi 6 technology and provides a wireless transmission speed of up to 2.4Gbps, which is suitable for high-bandwidth demand scenarios such as 4K streaming and gaming
VAR-202303-0901 CVE-2023-27401 Siemens Tecnomatix Plant Simulation SPP File Parsing Out-Of-Bounds Read Remote Code Execution Vulnerability CVSS V2: 7.2
CVSS V3: 7.8
Severity: HIGH
A vulnerability has been identified in Tecnomatix Plant Simulation (All versions < V2201.0006). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-20308, ZDI-CAN-20345). Siemens' Tecnomatix Plant Simulation Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of SPP files. Siemens Tecnomatix Plant Simulation is an industrial control equipment of German Siemens (Siemens). Leverage the power of discrete event simulation for throughput analysis and optimization to improve manufacturing system performance