VARIoT IoT vulnerabilities database
| VAR-202307-0615 | CVE-2023-37563 | Elecom radio LAN router and wireless LAN Multiple vulnerabilities in repeaters |
CVSS V2: 3.3 CVSS V3: 6.5 Severity: MEDIUM |
ELECOM wireless LAN routers are vulnerable to sensitive information exposure, which allows a network-adjacent unauthorized attacker to obtain sensitive information. Affected products and versions are as follows: WRC-1167GHBK-S v1.03 and earlier, WRC-1167GEBK-S v1.03 and earlier, WRC-1167FEBK-S v1.04 and earlier, WRC-1167GHBK3-A v1.24 and earlier, WRC-1167FEBK-A v1.18 and earlier, WRC-F1167ACF2 all versions, WRC-600GHBK-A all versions, WRC-733FEBK2-A all versions, WRC-1467GHBK-A all versions, WRC-1467GHBK-S all versions, WRC-1900GHBK-A all versions, and WRC-1900GHBK-S all versions. None
| VAR-202307-0616 | CVE-2023-37561 | Elecom radio LAN router and wireless LAN Multiple vulnerabilities in repeaters |
CVSS V2: 2.6 CVSS V3: 6.1 Severity: MEDIUM |
Open redirect vulnerability in ELECOM wireless LAN routers and ELECOM wireless LAN repeaters allows a remote unauthenticated attacker to redirect users to arbitrary web sites and conduct phishing attacks via a specially crafted URL. Affected products and versions are as follows: WRH-300WH-H v2.12 and earlier, WTC-300HWH v1.09 and earlier, WTC-C1167GC-B v1.17 and earlier, and WTC-C1167GC-W v1.17 and earlier. None
| VAR-202307-0618 | CVE-2023-37564 | Elecom radio LAN router and wireless LAN Multiple vulnerabilities in repeaters |
CVSS V2: 7.7 CVSS V3: 8.0 Severity: HIGH |
OS command injection vulnerability in ELECOM wireless LAN routers allows a network-adjacent authenticated attacker to execute an arbitrary OS command with a root privilege by sending a specially crafted request. Affected products and versions are as follows: WRC-1167GHBK-S v1.03 and earlier, WRC-1167GEBK-S v1.03 and earlier, WRC-1167FEBK-S v1.04 and earlier, WRC-1167GHBK3-A v1.24 and earlier, and WRC-1167FEBK-A v1.18 and earlier. None
| VAR-202307-0641 | CVE-2023-29130 | Siemens' simatic cn 4100 Vulnerability in |
CVSS V2: 10.0 CVSS V3: 9.9 Severity: CRITICAL |
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.5). Affected device consists of improper access controls in the configuration files that leads to privilege escalation. An attacker could gain admin access with this vulnerability leading to complete device control. Siemens' simatic cn 4100 Exists in unspecified vulnerabilities.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Siemens SIMATIC CN 4100 is a communication node of Siemens (Siemens) in Germany
| VAR-202307-0640 | CVE-2023-29131 | Siemens' simatic cn 4100 Vulnerability regarding improper default permissions in |
CVSS V2: 7.5 CVSS V3: 7.4 Severity: HIGH |
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V2.5). Affected device consists of an incorrect default value in the SSH configuration. This could allow an attacker to bypass network isolation. Siemens' simatic cn 4100 There is a vulnerability in improper default permissions.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Siemens SIMATIC CN 4100 is a communication node of Siemens (Siemens) in Germany
| VAR-202307-1027 | CVE-2022-23447 | Fortinet FortiExtender Path traversal vulnerability |
CVSS V2: - CVSS V3: 7.5 Severity: HIGH |
An improper limitation of a pathname to a restricted directory ('Path Traversal') vulnerability [CWE-22] in FortiExtender management interface 7.0.0 through 7.0.3, 4.2.0 through 4.2.4, 4.1.1 through 4.1.8, 4.0.0 through 4.0.2, 3.3.0 through 3.3.2, 3.2.1 through 3.2.3, 5.3 all versions may allow an unauthenticated and remote attacker to retrieve arbitrary files from the underlying filesystem via specially crafted web requests
| VAR-202307-1097 | CVE-2023-2746 | Rockwell Automation Enhanced HIM Cross-Site Request Forgery Vulnerability |
CVSS V2: 10.0 CVSS V3: 9.6 Severity: CRITICAL |
The Rockwell Automation Enhanced HIM software contains
an API that the application uses that is not protected sufficiently and uses incorrect Cross-Origin Resource Sharing (CORS) settings and, as a result, is vulnerable to a Cross Site Request Forgery (CSRF) attack. To exploit this vulnerability, a malicious user would have to convince a user to click on an untrusted link through a social engineering attack or successfully perform a Cross Site Scripting Attack (XSS). Exploitation of a CSRF could potentially lead to sensitive information disclosure and full remote access to the affected products. Rockwell Automation Provided by Enhanced HIM The following vulnerabilities exist in. It was * Cross-site request forgery (CWE-352) - CVE-2023-2746If the vulnerability is exploited, it may be affected as follows. It's a device used to interact with Rockwell Automation control systems, providing a more intuitive and convenient interface for operation and monitoring. Attackers can exploit this vulnerability to launch a CSRF attack
| VAR-202307-0591 | CVE-2023-36751 | Command injection vulnerability in multiple Siemens products |
CVSS V2: 10.0 CVSS V3: 7.2 Severity: HIGH |
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The install-app URL parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges. RUGGEDCOM ROX MX5000 firmware, ruggedcom rox mx5000re firmware, RUGGEDCOM ROX RX1400 Multiple Siemens products such as firmware contain a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. RUGGEDCOM products provide a level of robustness and reliability that sets the standard for communication networks deployed in harsh environments.
Siemens RUGGEDCOM ROX has a command injection vulnerability. The vulnerability stems from the lack of server-side input validation
| VAR-202307-0588 | CVE-2023-36750 | Command injection vulnerability in multiple Siemens products |
CVSS V2: 10.0 CVSS V3: 7.2 Severity: HIGH |
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The software-upgrade Url parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges. RUGGEDCOM ROX MX5000 firmware, ruggedcom rox mx5000re firmware, RUGGEDCOM ROX RX1400 Multiple Siemens products such as firmware contain a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. RUGGEDCOM products provide a level of robustness and reliability that sets the standard for communication networks deployed in harsh environments.
Siemens RUGGEDCOM ROX has a command injection vulnerability. The vulnerability stems from the lack of server-side input validation
| VAR-202307-0593 | CVE-2023-36752 | Command injection vulnerability in multiple Siemens products |
CVSS V2: 10.0 CVSS V3: 7.2 Severity: HIGH |
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The upgrade-app URL parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges. RUGGEDCOM ROX MX5000 firmware, ruggedcom rox mx5000re firmware, RUGGEDCOM ROX RX1400 Multiple Siemens products such as firmware contain a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. RUGGEDCOM products provide a level of robustness and reliability that sets the standard for communication networks deployed in harsh environments.
Siemens RUGGEDCOM ROX has a command injection vulnerability. The vulnerability stems from the lack of server-side input validation
| VAR-202307-0583 | CVE-2023-36753 | Command injection vulnerability in multiple Siemens products |
CVSS V2: 10.0 CVSS V3: 7.2 Severity: HIGH |
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The uninstall-app App-name parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges. RUGGEDCOM ROX MX5000 firmware, ruggedcom rox mx5000re firmware, RUGGEDCOM ROX RX1400 Multiple Siemens products such as firmware contain a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. RUGGEDCOM products provide a level of robustness and reliability that sets the standard for communication networks deployed in harsh environments.
Siemens RUGGEDCOM ROX has a command injection vulnerability. The vulnerability stems from the lack of server-side input validation
| VAR-202307-0594 | CVE-2023-36754 | Command injection vulnerability in multiple Siemens products |
CVSS V2: 10.0 CVSS V3: 7.2 Severity: HIGH |
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The SCEP server configuration URL parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges. RUGGEDCOM ROX MX5000 firmware, ruggedcom rox mx5000re firmware, RUGGEDCOM ROX RX1400 Multiple Siemens products such as firmware contain a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. RUGGEDCOM products provide a level of robustness and reliability that sets the standard for communication networks deployed in harsh environments.
Siemens RUGGEDCOM ROX has a command injection vulnerability. The vulnerability stems from the lack of server-side input validation
| VAR-202307-0590 | CVE-2023-36755 | Command injection vulnerability in multiple Siemens products |
CVSS V2: 10.0 CVSS V3: 7.2 Severity: HIGH |
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The SCEP CA Certificate Name parameter in the web interface of affected devices is vulnerable to command injection due to missing server side input sanitation. This could allow an authenticated privileged remote attacker to execute arbitrary code with root privileges. RUGGEDCOM ROX MX5000 firmware, ruggedcom rox mx5000re firmware, RUGGEDCOM ROX RX1400 Multiple Siemens products such as firmware contain a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. RUGGEDCOM products provide a level of robustness and reliability that sets the standard for communication networks deployed in harsh environments
| VAR-202307-0575 | CVE-2023-37247 | Siemens' tecnomatix Out-of-bounds write vulnerability in |
CVSS V2: 7.2 CVSS V3: 7.8 Severity: HIGH |
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PAR files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21138). Siemens' tecnomatix Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of PAR files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. Siemens Tecnomatix Plant Simulation is an industrial control device of Siemens, Germany. It uses discrete event simulation to analyze and optimize production volume, thereby improving the performance of manufacturing systems
| VAR-202307-0577 | CVE-2023-37246 | Siemens' tecnomatix Out-of-bounds write vulnerability in |
CVSS V2: 7.2 CVSS V3: 7.8 Severity: HIGH |
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PRT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21109). Siemens' tecnomatix Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of PRT files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. Siemens Tecnomatix Plant Simulation is an industrial control device of Siemens, Germany. It uses discrete event simulation to analyze and optimize production volume, thereby improving the performance of manufacturing systems
| VAR-202307-0572 | CVE-2023-37376 | Siemens' tecnomatix Vulnerability regarding mix-ups in |
CVSS V2: 7.2 CVSS V3: 7.8 Severity: HIGH |
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application contains a type confusion vulnerability while parsing STP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21051). Siemens' tecnomatix contains a type confusion vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of STP files. The issue results from the lack of proper validation of user-supplied data, which can result in a type confusion condition. Siemens Tecnomatix Plant Simulation is an industrial control device of Siemens, Germany. It uses discrete event simulation to analyze and optimize production volume, thereby improving the performance of manufacturing systems
| VAR-202307-0574 | CVE-2023-37248 | Siemens' tecnomatix Out-of-bounds write vulnerability in |
CVSS V2: 7.2 CVSS V3: 7.8 Severity: HIGH |
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application contains an out of bounds write past the end of an allocated buffer while parsing a specially crafted PAR file. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21155). Siemens' tecnomatix Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of PAR files. Siemens Tecnomatix Plant Simulation is an industrial control device of Siemens, Germany. It uses discrete event simulation to analyze and optimize production volume, thereby improving the performance of manufacturing systems
| VAR-202307-0573 | CVE-2023-37375 | Siemens' tecnomatix Out-of-bounds write vulnerability in |
CVSS V2: 7.2 CVSS V3: 7.8 Severity: HIGH |
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21060). Siemens' tecnomatix Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of SPP files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. Siemens Tecnomatix Plant Simulation is an industrial control device of Siemens, Germany. It uses discrete event simulation to analyze and optimize production volume, thereby improving the performance of manufacturing systems
| VAR-202307-0622 | CVE-2022-31810 | Siemens' SiPass integrated Out-of-bounds write vulnerability in |
CVSS V2: 7.8 CVSS V3: 7.5 Severity: HIGH |
A vulnerability has been identified in SiPass integrated (All versions < V2.90.3.8). Affected server applications improperly check the size of data packets received for the configuration client login, causing a stack-based buffer overflow.
This could allow an unauthenticated remote attacker to crash the server application, creating a denial of service condition. Siemens' SiPass integrated Exists in an out-of-bounds write vulnerability.Service operation interruption (DoS) It may be in a state. Siemens SiPass Integrated is an access control system from Siemens, Germany
| VAR-202307-0656 | CVE-2023-35921 | Vulnerabilities in multiple Siemens products |
CVSS V2: 7.8 CVSS V3: 7.5 Severity: HIGH |
A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3.4), SIMATIC MV540 S (All versions < V3.3.4), SIMATIC MV550 H (All versions < V3.3.4), SIMATIC MV550 S (All versions < V3.3.4), SIMATIC MV560 U (All versions < V3.3.4), SIMATIC MV560 X (All versions < V3.3.4). Affected devices cannot properly process specially crafted Ethernet frames sent to the devices. This could allow an unauthenticated remote attacker to cause a denial of service condition. The affected devices must be restarted manually. simatic mv540 h firmware, simatic mv540 s firmware, simatic mv550 h Multiple Siemens products such as firmware have unspecified vulnerabilities.Service operation interruption (DoS) It may be in a state. The SIMATIC MV500 products are fixed mount optical readers for capturing printed, laser, drilled, punched and dot-dash codes on a variety of different surfaces