VARIoT IoT vulnerabilities database
| VAR-202307-1157 | CVE-2023-36922 | SAP of SAP NetWeaver In OS Command injection vulnerability |
CVSS V2: - CVSS V3: 8.8 Severity: HIGH |
Due to programming error in function module and report, IS-OIL component in SAP ECC and SAP S/4HANA allows an authenticated attacker to inject an arbitrary operating system command into an unprotected parameter in a common (default) extension. On successful exploitation, the attacker can read or modify the system data as well as shut down the system. SAP of SAP NetWeaver for, OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
| VAR-202307-0577 | CVE-2023-37246 | Siemens' tecnomatix Out-of-bounds write vulnerability in |
CVSS V2: 7.2 CVSS V3: 7.8 Severity: HIGH |
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application is vulnerable to heap-based buffer overflow while parsing specially crafted PRT files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21109). Siemens' tecnomatix Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of PRT files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a heap-based buffer. Siemens Tecnomatix Plant Simulation is an industrial control device of Siemens, Germany. It uses discrete event simulation to analyze and optimize production volume, thereby improving the performance of manufacturing systems
| VAR-202307-0622 | CVE-2022-31810 | Siemens' SiPass integrated Out-of-bounds write vulnerability in |
CVSS V2: 7.8 CVSS V3: 7.5 Severity: HIGH |
A vulnerability has been identified in SiPass integrated (All versions < V2.90.3.8). Affected server applications improperly check the size of data packets received for the configuration client login, causing a stack-based buffer overflow.
This could allow an unauthenticated remote attacker to crash the server application, creating a denial of service condition. Siemens' SiPass integrated Exists in an out-of-bounds write vulnerability.Service operation interruption (DoS) It may be in a state. Siemens SiPass Integrated is an access control system from Siemens, Germany
| VAR-202307-0573 | CVE-2023-37375 | Siemens' tecnomatix Out-of-bounds write vulnerability in |
CVSS V2: 7.2 CVSS V3: 7.8 Severity: HIGH |
A vulnerability has been identified in Tecnomatix Plant Simulation V2201 (All versions < V2201.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0002). The affected application is vulnerable to stack-based buffer overflow while parsing specially crafted SPP files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-21060). Siemens' tecnomatix Exists in an out-of-bounds write vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of SPP files. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a stack-based buffer. Siemens Tecnomatix Plant Simulation is an industrial control device of Siemens, Germany. It uses discrete event simulation to analyze and optimize production volume, thereby improving the performance of manufacturing systems
| VAR-202307-0616 | CVE-2023-37561 | Elecom radio LAN router and wireless LAN Multiple vulnerabilities in repeaters |
CVSS V2: 2.6 CVSS V3: 6.1 Severity: MEDIUM |
Open redirect vulnerability in ELECOM wireless LAN routers and ELECOM wireless LAN repeaters allows a remote unauthenticated attacker to redirect users to arbitrary web sites and conduct phishing attacks via a specially crafted URL. Affected products and versions are as follows: WRH-300WH-H v2.12 and earlier, WTC-300HWH v1.09 and earlier, WTC-C1167GC-B v1.17 and earlier, and WTC-C1167GC-W v1.17 and earlier. None
| VAR-202307-0615 | CVE-2023-37563 | Elecom radio LAN router and wireless LAN Multiple vulnerabilities in repeaters |
CVSS V2: 3.3 CVSS V3: 6.5 Severity: MEDIUM |
ELECOM wireless LAN routers are vulnerable to sensitive information exposure, which allows a network-adjacent unauthorized attacker to obtain sensitive information. Affected products and versions are as follows: WRC-1167GHBK-S v1.03 and earlier, WRC-1167GEBK-S v1.03 and earlier, WRC-1167FEBK-S v1.04 and earlier, WRC-1167GHBK3-A v1.24 and earlier, WRC-1167FEBK-A v1.18 and earlier, WRC-F1167ACF2 all versions, WRC-600GHBK-A all versions, WRC-733FEBK2-A all versions, WRC-1467GHBK-A all versions, WRC-1467GHBK-S all versions, WRC-1900GHBK-A all versions, and WRC-1900GHBK-S all versions. None
| VAR-202307-0617 | CVE-2023-37565 | Elecom radio LAN router and wireless LAN Multiple vulnerabilities in repeaters |
CVSS V2: 5.2 CVSS V3: 8.0 Severity: HIGH |
Code injection vulnerability in ELECOM wireless LAN routers allows a network-adjacent authenticated attacker to execute arbitrary code by sending a specially crafted request. Affected products and versions are as follows: WRC-1167GHBK-S v1.03 and earlier, WRC-1167GEBK-S v1.03 and earlier, WRC-1167FEBK-S v1.04 and earlier, WRC-1167GHBK3-A v1.24 and earlier, and WRC-1167FEBK-A v1.18 and earlier. None
| VAR-202307-0620 | CVE-2023-37560 | Elecom radio LAN router and wireless LAN Multiple vulnerabilities in repeaters |
CVSS V2: 2.6 CVSS V3: 6.1 Severity: MEDIUM |
Cross-site scripting vulnerability in WRH-300WH-H v2.12 and earlier, and WTC-300HWH v1.09 and earlier allows a remote unauthenticated attacker to inject an arbitrary script. None
| VAR-202307-0618 | CVE-2023-37564 | Elecom radio LAN router and wireless LAN Multiple vulnerabilities in repeaters |
CVSS V2: 7.7 CVSS V3: 8.0 Severity: HIGH |
OS command injection vulnerability in ELECOM wireless LAN routers allows a network-adjacent authenticated attacker to execute an arbitrary OS command with a root privilege by sending a specially crafted request. Affected products and versions are as follows: WRC-1167GHBK-S v1.03 and earlier, WRC-1167GEBK-S v1.03 and earlier, WRC-1167FEBK-S v1.04 and earlier, WRC-1167GHBK3-A v1.24 and earlier, and WRC-1167FEBK-A v1.18 and earlier. None
| VAR-202307-0619 | CVE-2023-37562 | Elecom radio LAN router and wireless LAN Multiple vulnerabilities in repeaters |
CVSS V2: 2.6 CVSS V3: 8.8 Severity: HIGH |
Cross-site request forgery (CSRF) vulnerability in exists in WTC-C1167GC-B v1.17 and earlier, and WTC-C1167GC-W v1.17 and earlier. If a user views a malicious page while logged in, unintended operations may be performed. None
| VAR-202307-0586 | CVE-2022-29562 | Siemens RUGGEDCOM ROX Input Validation Error Vulnerability |
CVSS V2: 2.6 CVSS V3: 5.3 Severity: MEDIUM |
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). Affected devices do not properly handle malformed HTTP packets. This could allow an unauthenticated remote attacker to send a malformed HTTP packet causing certain functions to fail in a controlled manner. RUGGEDCOM ROX MX5000 firmware, ruggedcom rox mx5000re firmware, RUGGEDCOM ROX RX1400 Multiple Siemens products such as firmware have unspecified vulnerabilities.Service operation interruption (DoS) It may be in a state. RUGGEDCOM products provide a level of robustness and reliability that sets the standard for communication networks deployed in harsh environments
| VAR-202307-0657 | CVE-2023-35920 | Vulnerabilities in multiple Siemens products |
CVSS V2: 7.8 CVSS V3: 7.5 Severity: HIGH |
A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3.4), SIMATIC MV540 S (All versions < V3.3.4), SIMATIC MV550 H (All versions < V3.3.4), SIMATIC MV550 S (All versions < V3.3.4), SIMATIC MV560 U (All versions < V3.3.4), SIMATIC MV560 X (All versions < V3.3.4). Affected devices cannot properly process specially crafted IP packets sent to the devices. This could allow an unauthenticated remote attacker to cause a denial of service condition. The affected devices must be restarted manually. simatic mv540 h firmware, simatic mv540 s firmware, simatic mv550 h Multiple Siemens products such as firmware have unspecified vulnerabilities.Service operation interruption (DoS) It may be in a state. The SIMATIC MV500 products are fixed optical readers for capturing printed, laser, drilled, punched and dot-dash codes on a variety of different surfaces
| VAR-202307-0595 | CVE-2023-36386 | Cross-site scripting vulnerability in multiple Siemens products |
CVSS V2: 6.4 CVSS V3: 6.1 Severity: MEDIUM |
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link. The value is reflected in the response without sanitization while throwing an
“invalid params element name” error on the get_elements parameters. RUGGEDCOM ROX MX5000 firmware, ruggedcom rox mx5000re firmware, RUGGEDCOM ROX RX1400 Multiple Siemens products such as firmware contain a cross-site scripting vulnerability.Information may be obtained and information may be tampered with. RUGGEDCOM products provide a level of robustness and reliability that sets the standard for communication networks deployed in harsh environments
| VAR-202307-0589 | CVE-2023-36748 | Cryptographic strength vulnerabilities in multiple Siemens products |
CVSS V2: 5.8 CVSS V3: 6.8 Severity: MEDIUM |
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The affected devices are configured to offer weak ciphers by default. This could allow an unauthorized attacker in a man-in-the-middle position to read and modify any data
passed over to and from the affected device. RUGGEDCOM ROX MX5000 firmware, ruggedcom rox mx5000re firmware, RUGGEDCOM ROX RX1400 Multiple Siemens products, including firmware, have vulnerabilities related to encryption strength.Information may be obtained and information may be tampered with. RUGGEDCOM products provide a level of robustness and reliability that sets the standard for communication networks deployed in harsh environments
| VAR-202307-0585 | CVE-2023-36390 | Cross-site scripting vulnerability in multiple Siemens products |
CVSS V2: 6.4 CVSS V3: 8.8 Severity: HIGH |
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link. The value is reflected in the response
without sanitization while throwing an “invalid params element name” error on the action parameters. RUGGEDCOM ROX MX5000 firmware, ruggedcom rox mx5000re firmware, RUGGEDCOM ROX RX1400 Multiple Siemens products such as firmware contain a cross-site scripting vulnerability.Information may be obtained and information may be tampered with. RUGGEDCOM products provide a level of robustness and reliability that sets the standard for communication networks deployed in harsh environments
| VAR-202307-0592 | CVE-2023-36389 | Cross-site scripting vulnerability in multiple Siemens products |
CVSS V2: 6.4 CVSS V3: 6.1 Severity: MEDIUM |
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). A reflected cross-site scripting (XSS) vulnerability exists in the web interface of the affected application that could allow an attacker to execute malicious javascript code by tricking users into accessing a malicious link. The malformed value is reflected
directly in the response without sanitization while throwing an “invalid path” error. RUGGEDCOM ROX MX5000 firmware, ruggedcom rox mx5000re firmware, RUGGEDCOM ROX RX1400 Multiple Siemens products such as firmware contain a cross-site scripting vulnerability.Information may be obtained and information may be tampered with. RUGGEDCOM products provide a level of robustness and reliability that sets the standard for communication networks deployed in harsh environments
| VAR-202307-1097 | CVE-2023-2746 | Rockwell Automation Enhanced HIM Cross-Site Request Forgery Vulnerability |
CVSS V2: 10.0 CVSS V3: 9.6 Severity: CRITICAL |
The Rockwell Automation Enhanced HIM software contains
an API that the application uses that is not protected sufficiently and uses incorrect Cross-Origin Resource Sharing (CORS) settings and, as a result, is vulnerable to a Cross Site Request Forgery (CSRF) attack. To exploit this vulnerability, a malicious user would have to convince a user to click on an untrusted link through a social engineering attack or successfully perform a Cross Site Scripting Attack (XSS). Exploitation of a CSRF could potentially lead to sensitive information disclosure and full remote access to the affected products. Rockwell Automation Provided by Enhanced HIM The following vulnerabilities exist in. It was * Cross-site request forgery (CWE-352) - CVE-2023-2746If the vulnerability is exploited, it may be affected as follows. It's a device used to interact with Rockwell Automation control systems, providing a more intuitive and convenient interface for operation and monitoring. Attackers can exploit this vulnerability to launch a CSRF attack
| VAR-202307-0655 | CVE-2023-36521 | Vulnerability in limiting or non-slotting resource allocation in multiple Siemens products |
CVSS V2: 7.8 CVSS V3: 7.5 Severity: HIGH |
A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3.4), SIMATIC MV540 S (All versions < V3.3.4), SIMATIC MV550 H (All versions < V3.3.4), SIMATIC MV550 S (All versions < V3.3.4), SIMATIC MV560 U (All versions < V3.3.4), SIMATIC MV560 X (All versions < V3.3.4). The result synchronization server of the affected products contains a
vulnerability that may lead to a denial of service condition. An attacker may
cause a denial of service situation of all socket-based communication of the
affected products if the result server is enabled. simatic mv540 h firmware, simatic mv540 s firmware, simatic mv550 h Multiple Siemens products, including firmware, contain vulnerabilities related to limited or unthrottled resource allocation.Service operation interruption (DoS) It may be in a state. The SIMATIC MV500 products are fixed mount optical readers for capturing printed, laser, drilled, punched and dot-dash codes on a variety of different surfaces
| VAR-202307-0587 | CVE-2022-29561 | Siemens RUGGEDCOM ROX cross-site request forgery vulnerability |
CVSS V2: 7.6 CVSS V3: 8.8 Severity: HIGH |
A vulnerability has been identified in RUGGEDCOM ROX MX5000 (All versions < V2.16.0), RUGGEDCOM ROX MX5000RE (All versions < V2.16.0), RUGGEDCOM ROX RX1400 (All versions < V2.16.0), RUGGEDCOM ROX RX1500 (All versions < V2.16.0), RUGGEDCOM ROX RX1501 (All versions < V2.16.0), RUGGEDCOM ROX RX1510 (All versions < V2.16.0), RUGGEDCOM ROX RX1511 (All versions < V2.16.0), RUGGEDCOM ROX RX1512 (All versions < V2.16.0), RUGGEDCOM ROX RX1524 (All versions < V2.16.0), RUGGEDCOM ROX RX1536 (All versions < V2.16.0), RUGGEDCOM ROX RX5000 (All versions < V2.16.0). The web interface of the affected devices are vulnerable to Cross-Site Request Forgery attacks. By tricking an authenticated victim user to click a malicious link, an attacker could perform arbitrary actions on the device on behalf of the victim user. RUGGEDCOM ROX MX5000 firmware, ruggedcom rox mx5000re firmware, RUGGEDCOM ROX RX1400 Multiple Siemens products, including firmware, are vulnerable to cross-site request forgery.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. RUGGEDCOM products provide a level of robustness and reliability that sets the standard for communication networks deployed in harsh environments
| VAR-202307-1275 | CVE-2023-2072 | Rockwell Automation Made PowerMonitor 1000 Cross-site scripting vulnerability in |
CVSS V2: 10.0 CVSS V3: 8.8 Severity: HIGH |
The Rockwell Automation PowerMonitor 1000 contains stored cross-site scripting vulnerabilities within the web page of the product. The vulnerable pages do not require privileges to access and can be injected with code by an attacker which could be used to leverage an attack on an authenticated user resulting in remote code execution and potentially the complete loss of confidentiality, integrity, and availability of the product. It was * Cross-site scripting (CWE-79) - CVE-2023-2072If the vulnerability is exploited, it may be affected as follows. Rockwell Automation PowerMonitor 1000 is a power monitoring device from Rockwell Automation, USA. The vulnerability is caused by the lack of effective filtering and escaping of user-supplied data