VARIoT IoT vulnerabilities database

Affected products: vendor, model and version
CWE format is 'CWE-number'. Threat type can be: remote or local
Look up free text in title and description

VAR-202311-0932 CVE-2022-45781 Shenzhen Tenda Technology Co.,Ltd.  of  ax1803  Out-of-bounds write vulnerability in firmware CVSS V2: 9.0
CVSS V3: 8.8
Severity: HIGH
Buffer Overflow vulnerability in Tenda AX1803 v1.0.0.1_2994 and earlier allows attackers to run arbitrary code via /goform/SetOnlineDevName. Shenzhen Tenda Technology Co.,Ltd. of ax1803 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. This vulnerability is caused by the program failing to correctly verify the length of the input data
VAR-202311-1151 CVE-2023-42783 CVSS V2: -
CVSS V3: 7.5
Severity: HIGH
A relative path traversal in Fortinet FortiWLM version 8.6.0 through 8.6.5 and 8.5.0 through 8.5.4 and 8.4.2 through 8.4.0 and 8.3.2 through 8.3.0 and 8.2.2 allows attacker to read arbitrary files via crafted http requests.
VAR-202311-1591 CVE-2023-34991 Fortinet FortiWLM SQL injection vulnerability (CNVD-2024-13757) CVSS V2: 10.0
CVSS V3: 9.8
Severity: CRITICAL
A improper neutralization of special elements used in an sql command ('sql injection') in Fortinet FortiWLM version 8.6.0 through 8.6.5 and 8.5.0 through 8.5.4 and 8.4.0 through 8.4.2 and 8.3.0 through 8.3.2 and 8.2.2 allows attacker to execute unauthorized code or commands via a crafted http request. Fortinet FortiWLM is a wireless manager from the American company Fortinet. Fortinet FortiWLM has a SQL injection vulnerability, which results from the application's lack of validation of externally input SQL statements
VAR-202311-0653 CVE-2023-46590 Siemens'  siemens opc ua modeling editor  In  XML  External entity vulnerabilities CVSS V2: 7.8
CVSS V3: 7.5
Severity: HIGH
A vulnerability has been identified in Siemens OPC UA Modelling Editor (SiOME) (All versions < V2.8). Affected products suffer from a XML external entity (XXE) injection vulnerability. This vulnerability could allow an attacker to interfere with an application's processing of XML data and read arbitrary files in the system
VAR-202311-0457 CVE-2023-46099 Siemens'  SIMATIC PCS neo  Cross-site scripting vulnerability in CVSS V2: 5.2
CVSS V3: 4.8
Severity: MEDIUM
A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). There is a stored cross-site scripting vulnerability in the Administration Console of the affected product, that could allow an attacker with high privileges to inject Javascript code into the application that is later executed by another legitimate user. Siemens' SIMATIC PCS neo Exists in a cross-site scripting vulnerability.Information may be obtained and information may be tampered with. SIMATIC PCS neo is a distributed control system (DCS)
VAR-202311-0460 CVE-2023-46098 Siemens'  SIMATIC PCS neo  Overly permissive cross-domain whitelisting vulnerability in CVSS V2: 8.3
CVSS V3: 8.8
Severity: HIGH
A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). When accessing the Information Server from affected products, the products use an overly permissive CORS policy. This could allow an attacker to trick a legitimate user to trigger unwanted behavior. Siemens' SIMATIC PCS neo contains an overly permissive cross-domain whitelisting vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. SIMATIC PCS neo is a distributed control system (DCS)
VAR-202311-0458 CVE-2023-46097 Siemens'  SIMATIC PCS neo  In  SQL  Injection vulnerability CVSS V2: 6.2
CVSS V3: 8.0
Severity: HIGH
A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). The PUD Manager of affected products does not properly neutralize user provided inputs. This could allow an authenticated adjacent attacker to execute SQL statements in the underlying database. Siemens' SIMATIC PCS neo for, SQL There is an injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. SIMATIC PCS neo is a distributed control system (DCS)
VAR-202311-0459 CVE-2023-46096 Siemens'  SIMATIC PCS neo  Vulnerability regarding lack of authentication for critical features in CVSS V2: 6.1
CVSS V3: 6.5
Severity: MEDIUM
A vulnerability has been identified in SIMATIC PCS neo (All versions < V4.1). The PUD Manager of affected products does not properly authenticate users in the PUD Manager web service. This could allow an unauthenticated adjacent attacker to generate a privileged token and upload additional documents. SIMATIC PCS neo is a distributed control system (DCS)
VAR-202311-1522 CVE-2023-27519 CVSS V2: -
CVSS V3: 7.8
Severity: HIGH
Improper input validation in firmware for some Intel(R) Optane(TM) SSD products may allow a privileged user to potentially enable escalation of privilege via local access
VAR-202311-0527 CVE-2023-44445 of netgear  CAX30  Out-of-bounds write vulnerability in firmware CVSS V2: 8.3
CVSS V3: 8.8
Severity: HIGH
NETGEAR CAX30 SSO Stack-based Buffer Overflow Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of NETGEAR CAX30 routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the sso binary. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-19058. of netgear CAX30 An out-of-bounds write vulnerability exists in firmware.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The NETGEAR CAX30 is a 6-Stream WiFi 6 router from Netgear's Nighthawk AX6 series. It supports DOCSIS 3.1 technology and provides multi-gigabit internet and wireless speeds, making it suitable for simultaneous use of smart home devices during peak hours
VAR-202311-1268 CVE-2023-27306 Initialization vulnerabilities in multiple Intel products CVSS V2: -
CVSS V3: 5.5
Severity: MEDIUM
Improper Initialization in firmware for some Intel(R) Optane(TM) SSD products may allow an authenticated user to potentially enable denial of service via local access. optane memory h20 with solid state storage firmware, Intel Optane SSD 900P , optane ssd dc p4800x Multiple Intel products, including firmware, have vulnerabilities related to initialization.Service operation interruption (DoS) It may be in a state
VAR-202311-1185 CVE-2023-24588 CVSS V2: -
CVSS V3: 4.6
Severity: MEDIUM
Exposure of sensitive information to an unauthorized actor in firmware for some Intel(R) Optane(TM) SSD products may allow an unauthenticated user to potentially enable information disclosure via physical access
VAR-202311-0659 CVE-2023-39471 TP-LINK Technologies  of  TL-WR841N  firmware and  TL-WR840N  Command injection vulnerability in firmware CVSS V2: -
CVSS V3: 7.5
Severity: HIGH
TP-Link TL-WR841N ated_tp Command Injection Remote Code Execution Vulnerability. This vulnerability allows network-adjacent attackers to execute arbitrary code on affected installations of TP-Link TL-WR841N routers. Authentication is not required to exploit this vulnerability. The specific flaw exists within the ated_tp service. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-21825. TP-LINK Technologies of TL-WR841N firmware and TL-WR840N Firmware contains a command injection vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state
VAR-202311-0438 CVE-2023-44320 Direct request vulnerability in multiple Siemens products CVSS V2: 4.0
CVSS V3: 4.3
Severity: MEDIUM
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V7.2.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V7.2.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V7.2.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V7.2.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V7.2.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V7.2.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V7.2.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V7.2.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V7.2.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V7.2.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V7.2.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V7.2.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V7.2.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V7.2.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V7.2.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V7.2.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V7.2.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V7.2.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V7.2.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V7.2.2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V3.0.0). Affected devices do not properly validate the authentication when performing certain modifications in the web interface allowing an authenticated attacker to influence the user interface configured by an administrator. 6gk5205-3bb00-2ab2 firmware, 6gk5205-3bb00-2tb2 firmware, 6gk5205-3bd00-2tb2 Multiple Siemens products, including firmware, contain vulnerabilities related to direct request submission.Information may be tampered with. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers. SCALANCE W products are wireless communication devices for connecting industrial components, such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), in compliance with the IEEE 802.11 standards (802.11ac, 802.11a/b/g/h and/or 802.11n). The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. They are used to connect various WLAN devices (access points or clients, depending on the operating mode), focusing on industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI), etc. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLCs) or human-machine interfaces (HMIs). Several Siemens products have forced browsing vulnerabilities that attackers can exploit to affect the user interface configured by administrators
VAR-202311-1000 CVE-2023-24587 CVSS V2: -
CVSS V3: 4.4
Severity: MEDIUM
Insufficient control flow management in firmware for some Intel(R) Optane(TM) SSD products may allow a privileged user to potentially enable denial of service via local access
VAR-202311-0436 CVE-2023-44322 Unchecked return value vulnerability in multiple Siemens products CVSS V2: 2.6
CVSS V3: 3.7
Severity: LOW
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.0), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.0), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.0), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.0), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V3.0.0). Affected devices can be configured to send emails when certain events occur on the device. When presented with an invalid response from the SMTP server, the device triggers an error that disrupts email sending. An attacker with access to the network can use this to do disable notification of users when certain events occur. 6gk5205-3bb00-2ab2 firmware, 6gk5205-3bb00-2tb2 firmware, 6gk5205-3bd00-2tb2 Multiple Siemens products, including firmware, contain vulnerabilities related to unchecked return values.Service operation interruption (DoS) It may be in a state. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers. SCALANCE W products are wireless communication devices for connecting industrial components, such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), in compliance with the IEEE 802.11 standards (802.11ac, 802.11a/b/g/h and/or 802.11n). The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. They are used to connect various WLAN devices (access points or clients, depending on the operating mode), focusing on industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI), etc. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLCs) or human-machine interfaces (HMIs)
VAR-202311-0441 CVE-2023-44319 Weak hash usage vulnerability in multiple Siemens products CVSS V2: 6.8
CVSS V3: 4.9
Severity: Medium
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.0), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.0), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.0), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.0), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V3.0.0). Affected devices use a weak checksum algorithm to protect the configuration backup that an administrator can export from the device. This could allow an authenticated attacker with administrative privileges or an attacker that tricks a legitimate administrator to upload a modified configuration file to change the configuration of an affected device. 6gk5205-3bb00-2ab2 firmware, 6gk5205-3bb00-2tb2 firmware, 6gk5205-3bd00-2tb2 Multiple Siemens products, including firmware, contain vulnerabilities related to the use of weak hashes.Information may be tampered with. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers. SCALANCE W products are wireless communication devices for connecting industrial components, such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), in compliance with the IEEE 802.11 standards (802.11ac, 802.11a/b/g/h and/or 802.11n). The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. They are used to connect various WLAN devices (access points or clients, depending on the operating mode), focusing on industrial components such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), etc. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLCs) or human-machine interfaces (HMIs)
VAR-202311-0437 CVE-2023-44374 Vulnerabilities in multiple Siemens products involving asynchronous access to shared data within a multi-threaded context CVSS V2: 6.8
CVSS V3: 6.5
Severity: High
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V8.0), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V8.0), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V8.0), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V8.0), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V8.0), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V8.0), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V8.0), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V8.0), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V8.0), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V8.0), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V8.0), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V8.0), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V8.0), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V8.0), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V8.0), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V8.0), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V8.0), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V3.0.0). Affected devices allow to change the password, but insufficiently check which password is to be changed. With this an authenticated attacker could, under certain conditions, be able to change the password of another, potential admin user, which could allow to escalate privileges. 6gk5205-3bb00-2ab2 firmware, 6gk5205-3bb00-2tb2 firmware, 6gk5205-3bd00-2tb2 Multiple Siemens products, including firmware, contain vulnerabilities related to asynchronous access to shared data within a multi-threaded context.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers. SCALANCE W products are wireless communication devices for connecting industrial components, such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), in compliance with the IEEE 802.11 standards (802.11ac, 802.11a/b/g/h and/or 802.11n). The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. They are used to connect various WLAN devices (access points or clients, depending on the operating mode), focusing on industrial components such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), etc. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLCs) or human-machine interfaces (HMIs)
VAR-202311-1187 CVE-2023-20592 AMD CPU Instruction Misconception CVSS V2: 6.8
CVSS V3: 6.5
Severity: MEDIUM
Improper or unexpected behavior of the INVD instruction in some AMD CPUs may allow an attacker with a malicious hypervisor to affect cache line write-back behavior of the CPU leading to a potential loss of guest virtual machine (VM) memory integrity. AMD CPUs are a series of CPUs from AMD Inc. AMD CPUs contain a misguided instruction vulnerability. The following advisory data is extracted from: https://access.redhat.com/security/data/csaf/v2/advisories/2024/rhsa-2024_0753.json Red Hat officially shut down their mailing list notifications October 10, 2023. Due to this, Packet Storm has recreated the below data as a reference point to raise awareness. It must be noted that due to an inability to easily track revision updates without crawling Red Hat's archive, these advisories are single notifications and we strongly suggest that you visit the Red Hat provided links to ensure you have the latest information available if the subject matter listed pertains to your environment. - Packet Storm Staff ==================================================================== Red Hat Security Advisory Synopsis: Moderate: linux-firmware security update Advisory ID: RHSA-2024:0753-03 Product: Red Hat Enterprise Linux Advisory URL: https://access.redhat.com/errata/RHSA-2024:0753 Issue date: 2024-02-09 Revision: 03 CVE Names: CVE-2023-20592 ==================================================================== Summary: An update for linux-firmware is now available for Red Hat Enterprise Linux 7. Red Hat Product Security has rated this update as having a security impact of Moderate. A Common Vulnerability Scoring System (CVSS) base score, which gives a detailed severity rating, is available for each vulnerability from the CVE link(s) in the References section. Description: The linux-firmware packages contain all of the firmware files that are required by various devices to operate. Security Fix(es): * (RCVE-2023-20592) For more details about the security issue(s), including the impact, a CVSS score, acknowledgments, and other related information, refer to the CVE page(s) listed in the References section. Solution: https://access.redhat.com/articles/11258 CVEs: CVE-2023-20592 References: https://access.redhat.com/security/updates/classification/#moderate https://bugzilla.redhat.com/show_bug.cgi?id=2244590
VAR-202311-0440 CVE-2023-44317 Untrusted irrelevant data acceptance vulnerability when accepting trusted data in multiple Siemens products CVSS V2: 9.0
CVSS V3: 7.2
Severity: High
A vulnerability has been identified in RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) (All versions < V7.2.2), RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) (All versions < V7.2.2), SCALANCE M804PB (6GK5804-0AP00-2AA2) (All versions < V7.2.2), SCALANCE M812-1 ADSL-Router (6GK5812-1AA00-2AA2) (All versions < V7.2.2), SCALANCE M812-1 ADSL-Router (6GK5812-1BA00-2AA2) (All versions < V7.2.2), SCALANCE M816-1 ADSL-Router (6GK5816-1AA00-2AA2) (All versions < V7.2.2), SCALANCE M816-1 ADSL-Router (6GK5816-1BA00-2AA2) (All versions < V7.2.2), SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) (All versions < V7.2.2), SCALANCE M874-2 (6GK5874-2AA00-2AA2) (All versions < V7.2.2), SCALANCE M874-3 (6GK5874-3AA00-2AA2) (All versions < V7.2.2), SCALANCE M876-3 (6GK5876-3AA02-2BA2) (All versions < V7.2.2), SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) (All versions < V7.2.2), SCALANCE M876-4 (6GK5876-4AA10-2BA2) (All versions < V7.2.2), SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) (All versions < V7.2.2), SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) (All versions < V7.2.2), SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) (All versions < V7.2.2), SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) (All versions < V7.2.2), SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) (All versions < V7.2.2), SCALANCE S615 EEC LAN-Router (6GK5615-0AA01-2AA2) (All versions < V7.2.2), SCALANCE S615 LAN-Router (6GK5615-0AA00-2AA2) (All versions < V7.2.2), SCALANCE WAB762-1 (6GK5762-1AJ00-6AA0) (All versions < V3.0.0), SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) (All versions < V3.0.0), SCALANCE WAM763-1 (ME) (6GK5763-1AL00-7DC0) (All versions < V3.0.0), SCALANCE WAM763-1 (US) (6GK5763-1AL00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 (6GK5766-1GE00-7DA0) (All versions < V3.0.0), SCALANCE WAM766-1 (ME) (6GK5766-1GE00-7DC0) (All versions < V3.0.0), SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (6GK5766-1GE00-7TA0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (ME) (6GK5766-1GE00-7TC0) (All versions < V3.0.0), SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) (All versions < V3.0.0), SCALANCE WUB762-1 (6GK5762-1AJ00-1AA0) (All versions < V3.0.0), SCALANCE WUB762-1 iFeatures (6GK5762-1AJ00-2AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) (All versions < V3.0.0), SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3AB0) (All versions < V3.0.0), SCALANCE WUM763-1 (US) (6GK5763-1AL00-3DB0) (All versions < V3.0.0), SCALANCE WUM766-1 (6GK5766-1GE00-3DA0) (All versions < V3.0.0), SCALANCE WUM766-1 (ME) (6GK5766-1GE00-3DC0) (All versions < V3.0.0), SCALANCE WUM766-1 (USA) (6GK5766-1GE00-3DB0) (All versions < V3.0.0). Affected products do not properly validate the content of uploaded X509 certificates which could allow an attacker with administrative privileges to execute arbitrary code on the device. scalance xb208 (e/ip) firmware, scalance xb208 (pn) firmware, scalance xb216 (e/ip) Multiple Siemens products, including firmware, contain vulnerabilities that allow untrusted, unrelated data to be accepted when trusted data is accepted.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. SCALANCE M-800, MUM-800 and S615 as well as RUGGEDCOM RM1224 are industrial routers. SCALANCE W products are wireless communication devices for connecting industrial components, such as programmable logic controllers (PLCs) or human machine interfaces (HMIs), in compliance with the IEEE 802.11 standards (802.11ac, 802.11a/b/g/h and/or 802.11n). The SCALANCE W-1700 product is a wireless communication device based on the IEEE 802.11ac standard. They are used to connect various WLAN devices (access points or clients, depending on the operating mode), focusing on industrial components such as programmable logic controllers (PLC) or human machine interfaces (HMI), etc. SCALANCE X switches are used to connect industrial components such as programmable logic controllers (PLCs) or human-machine interfaces (HMIs)