| VAR-201708-1409 | CVE-2017-9662 | Fuji Electric Monitouch V-SFT Insecure Configuration Privilege Escalation Vulnerability |
CVSS V2: 4.6 CVSS V3: 5.3 Severity: MEDIUM |
An Improper Privilege Management issue was discovered in Fuji Electric Monitouch V-SFT versions prior to Version 5.4.43.0. Monitouch V-SFT is installed in a directory with weak access controls by default, which could allow an authenticated attacker with local access to escalate privileges. Fuji Electric Monitouch V-SFT Contains vulnerabilities related to authorization, permissions, and access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. This vulnerability allows local attackers to escalate their privileges on vulnerable installations of Fuji Electric Monitouch V-SFT. An attacker must first obtain the ability to execute low-privileged code on the target system in order to exploit this vulnerability.The specific flaw exists within the configuration of Monitouch V-SFT. An attacker can leverage this vulnerability to execute code in the context of any user of the software. Fuji Electric Monitouch V-SFT is an HMI software
| VAR-201708-1405 | CVE-2017-9655 | OSIsoft PI Integrator Cross-Site Scripting Vulnerability |
CVSS V2: 3.5 CVSS V3: 5.4 Severity: MEDIUM |
A Cross-Site Scripting issue was discovered in OSIsoft PI Integrator for Business Analytics before 2016 R2, PI Integrator for Microsoft Azure before 2016 R2 SP1, and PI Integrator for SAP HANA before 2017. An attacker may be able to upload a malicious script that attempts to redirect users to a malicious web site. OSIsoft PI Integrator Contains a cross-site scripting vulnerability.Information may be obtained and information may be altered. OSIsoft PI Integrator is a tool for OSIsoft to provide visual data for external systems.
An attacker may leverage these issues to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site, steal cookie-based authentication credentials, or gain elevated privileges and perform unauthorized actions. This may aid in further attacks
| VAR-201708-1404 | CVE-2017-9653 | OSIsoft PI Integrator Unauthorized Access Vulnerability |
CVSS V2: 7.5 CVSS V3: 9.8 Severity: CRITICAL |
An Improper Authorization issue was discovered in OSIsoft PI Integrator for Business Analytics before 2016 R2, PI Integrator for Microsoft Azure before 2016 R2 SP1, and PI Integrator for SAP HANA before 2017. An attacker is able to gain privileged access to the system while unauthorized. OSIsoft PI Integrator is a tool for OSIsoft to provide visual data for external systems. An unauthorized access vulnerability exists in OSIsoft PI Integrator.
An attacker may leverage these issues to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site, steal cookie-based authentication credentials, or gain elevated privileges and perform unauthorized actions. This may aid in further attacks
| VAR-201708-1408 | CVE-2017-9661 | SIMPlight SCADA Software DLL Load Local Code Execution Vulnerability |
CVSS V2: 5.1 CVSS V3: 7.0 Severity: HIGH |
An Uncontrolled Search Path Element issue was discovered in SIMPlight SCADA Software version 4.3.0.27 and prior. The uncontrolled search path element vulnerability has been identified, which may allow an attacker to place a malicious DLL file within the search path resulting in execution of arbitrary code. SIMPlight SCADA The software contains a vulnerability related to uncontrolled search path elements.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. SIMPlight SCADA is a building management system and automation equipment software. SIMPlight SCADA Software is prone to a local arbitrary code-execution vulnerability because it fails to sanitize user-supplied input.
A local attacker can exploit this issue to execute arbitrary code in the context of the user running the affected application.
SIMPlight SCADA Software 4.3.0.27 and prior versions are vulnerable
| VAR-201801-0997 | CVE-2017-2743 | plural HP Cross-site scripting vulnerability in printer product firmware |
CVSS V2: 4.3 CVSS V3: 6.1 Severity: MEDIUM |
HP has identified a potential security vulnerability with HP Enterprise LaserJet Printers and MFPs, HP OfficeJet Enterprise Color Printers and MFP, HP PageWide Color Printers and MPS before 2308214_000901, 2308214_000900, and other firmware versions. The vulnerability could be exploited to perform a cross site scripting (XSS) attack. plural HP Printer product firmware contains a cross-site scripting vulnerability.Information may be obtained and information may be altered. HPColorLaserJetCM4540MFPCC419A and so on are all HP (HP) printer equipment. A cross-site scripting vulnerability exists in several HP products. A remote attacker can exploit this vulnerability to inject arbitrary web scripts or HTML. This may allow the attacker to steal cookie-based authentication credentials and launch other attacks
| VAR-201708-1400 | CVE-2017-9646 | Solar Controls Heating Control Downloader DLL Load Local Code Execution Vulnerability |
CVSS V2: 9.3 CVSS V3: 7.8 Severity: HIGH |
An Uncontrolled Search Path Element issue was discovered in Solar Controls Heating Control Downloader (HCDownloader) Version 1.0.1.15 and prior. An uncontrolled search path element has been identified, which could allow an attacker to execute arbitrary code on a target system using a malicious DLL file. A security vulnerability exists in Solar Controls HCDownloader 1.0.1.15 and earlier
| VAR-201708-1402 | CVE-2017-9648 | Solar Controls WATTConfig M Software DLL Load Local Code Execution Vulnerability |
CVSS V2: 9.3 CVSS V3: 7.8 Severity: HIGH |
An Uncontrolled Search Path Element issue was discovered in Solar Controls WATTConfig M Software Version 2.5.10.1 and prior. An uncontrolled search path element has been identified, which could allow an attacker to execute arbitrary code on a target system using a malicious DLL file
| VAR-201708-1401 | CVE-2017-9647 | Continental TCU Stack Buffer Overflow Vulnerability |
CVSS V2: 7.2 CVSS V3: 6.6 Severity: MEDIUM |
A Stack-Based Buffer Overflow issue was discovered in the Continental AG Infineon S-Gold 2 (PMB 8876) chipset on BMW several models produced between 2009-2010, Ford a limited number of P-HEV vehicles, Infiniti 2013 JX35, Infiniti 2014-2016 QX60, Infiniti 2014-2016 QX60 Hybrid, Infiniti 2014-2015 QX50, Infiniti 2014-2015 QX50 Hybrid, Infiniti 2013 M37/M56, Infiniti 2014-2016 Q70, Infiniti 2014-2016 Q70L, Infiniti 2015-2016 Q70 Hybrid, Infiniti 2013 QX56, Infiniti 2014-2016 QX 80, and Nissan 2011-2015 Leaf. An attacker with a physical connection to the TCU may exploit a buffer overflow condition that exists in the processing of AT commands. This may allow arbitrary code execution on the baseband radio processor of the TCU. The TCU is a 2G modem commonly used in modern cars produced by Continental AG to transmit data between cars and remote management tools such as web panels and mobile applications. Continental TCU has a stack buffer overflow vulnerability that affects TCUs using S-Gold 2 (PMB 8876) cellular baseband chips. Continental AG Infineon S-Gold 2 (PMB 8876) is prone to a remote code-execution vulnerability and a stack-based buffer-overflow vulnerability; fixes are available. Failed exploit attempts will likely result in denial-of-service conditions
| VAR-201805-0355 | CVE-2017-9664 | ABB SREA-01 and SREA-50 Path traversal vulnerability |
CVSS V2: 5.0 CVSS V3: 9.8 Severity: CRITICAL |
In ABB SREA-01 revisions A, B, C: application versions up to 3.31.5, and SREA-50 revision A: application versions up to 3.32.8, an attacker may access internal files of ABB SREA-01 and SREA-50 legacy remote monitoring tools without any authorization over the network using a HTTP request which refers to files using ../../ relative paths. Once the internal password file is retrieved, the password hash can be identified using a brute force attack. There is also an exploit allowing running of commands after authorization. ABB SREA-01 and SREA-50 Contains a path traversal vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Both ABBSREA-01 and SREA-50 are inverter adapters from Asea Brown Boveri (ABB), Switzerland. A directory traversal vulnerability exists in ABBSREA-01 and SREA-50. An attacker who successfully exploited the vulnerability could access files on the file system of the affected product, view the data, change the configuration, retrieve the password hash code, and send commands to connect to Authorized device. ABB SREA-01 and SREA-50 are prone to a directory-traversal vulnerability.
Remote attackers may use a specially crafted request with directory-traversal sequences ('../') to retrieve sensitive information. This may aid in further attacks.
The following products are affected:
SREA-01 revisions A, B, C version 3.31.5 and prior.
SREA-50 revision A version 3.32.8 and prior
| VAR-201708-1403 | CVE-2017-9650 | plural ALC Product unrestricted upload vulnerability |
CVSS V2: 4.6 CVSS V3: 7.8 Severity: HIGH |
An Unrestricted Upload of File with Dangerous Type issue was discovered in Automated Logic Corporation (ALC) ALC WebCTRL, i-Vu, SiteScan Web 6.5 and prior; ALC WebCTRL, SiteScan Web 6.1 and prior; ALC WebCTRL, i-Vu 6.0 and prior; ALC WebCTRL, i-Vu, SiteScan Web 5.5 and prior; and ALC WebCTRL, i-Vu, SiteScan Web 5.2 and prior. An authenticated attacker may be able to upload a malicious file allowing the execution of arbitrary code. ALC WebCTRL , i-Vu ,and SiteScan Web Contains a vulnerability related to unlimited uploads of dangerous types of files.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. ALC WebCTRL is a building automation platform. Multiple Automated Logic Corporation Products are prone to a directory-traversal vulnerability and an arbitrary-file-upload vulnerability. WebCTRL®, Automated Logic's web-based building automationsystem, is known for its intuitive user interface and powerful integrationcapabilities. It allows building operators to optimize and manageall of their building systems - including HVAC, lighting, fire, elevators,and security - all within a single HVAC controls platform. It's everythingthey need to keep occupants comfortable, manage energy conservation measures,identify key operational problems, and validate the results.WebCTRL suffers from an authenticated arbitrary code execution vulnerability. The issue is caused due to the improper verification when uploading Add-on (.addons or .war) files using the uploadwarfile servlet. Additionaly, an improper authorization access control occurs when using the 'anonymous' user. By specification, the anonymous user should not have permissions or authorization to upload or install add-ons. The anonymous user was removed from version 6.5 of WebCTRL.Tested on: Microsoft Windows 7 Professional (6.1.7601 Service Pack 1 Build 7601)Apache-Coyote/1.1Apache Tomcat/7.0.42CJServer/1.1Java/1.7.0_25-b17Java HotSpot Server VM 23.25-b01Ant 1.7.0Axis 1.4Trove 2.0.2Xalan Java 2.4.1Xerces-J 2.6.1. The vulnerability exist due to the improper permissions,with the 'M' flag (Modify) or 'C' flag (Change) for 'Authenticated Users' group.The application suffers from an unquoted search path issue as well impacting the service'WebCTRL Service' for Windows deployed as part of WebCTRL server solution. This couldpotentially allow an authorized but non-privileged local user to execute arbitrarycode with elevated privileges on the system. A successful attempt would require thelocal user to be able to insert their code in the system root path undetected by theOS or other security applications where it could potentially be executed duringapplication startup or reboot. If successful, the local user’s code would executewith the elevated privileges of the application.Tested on: Microsoft Windows 7 Professional SP1 (EN)
| VAR-201801-1099 | CVE-2017-9663 | General Motors - Shanghai OnStar of SOS iOS Client Vulnerable to information disclosure |
CVSS V2: 5.0 CVSS V3: 7.5 Severity: HIGH |
An Cleartext Storage of Sensitive Information issue was discovered in General Motors (GM) and Shanghai OnStar (SOS) SOS iOS Client 7.1. Successful exploitation of this vulnerability may allow a remote attacker to access an encryption key that is stored in cleartext in memory. General Motors Shanghai OnStar is prone to multiple security vulnerabilities.
An attackers may exploit these issues to gain unauthorized complete access to the affected application by bypassing intended security restrictions or perform man-in-the-middle attack to edit or view sensitive information that may aid in launching further attacks.
Shanghai OnStar 7.1 is vulnerable; other versions may also be affected
| VAR-201709-1106 | CVE-2017-9645 | plural Mirion Technologies Vulnerability related to cryptographic strength in products |
CVSS V2: 3.3 CVSS V3: 6.5 Severity: MEDIUM |
An Inadequate Encryption Strength issue was discovered in Mirion Technologies DMC 3000 Transmitter Module, iPam Transmitter f/DMC 2000, RDS-31 iTX and variants (including RSD31-AM Package), DRM-1/2 and variants (including Solar PWR Package), DRM and RDS Based Boundary Monitors, External Transmitters, Telepole II, and MESH Repeater (Telemetry Enabled Devices). Decryption of data is possible at the hardware level. plural Mirion Technologies The product contains a vulnerability related to cryptographic strength.Information may be obtained. Mirion Technologies provides a source of solutions for nuclear, military, radiation detection and monitoring. Mirion Technologies Telemetry Enabled Devices is a denial of service vulnerability that could be exploited by an attacker to transmit fraudulent data or perform denial of service.
Successfully exploiting these issues may allow an attacker to bypass certain security restrictions and perform unauthorized actions. This may aid in further attacks. RSD31-AM Package),
DRM-1/2 and variants (incl. Security vulnerabilities exist in several Mirion Technologies products
| VAR-201709-1107 | CVE-2017-9649 | Mirion Technologies Telemetry Enabled Devices Denial of service vulnerability |
CVSS V2: 5.4 CVSS V3: 5.0 Severity: MEDIUM |
A Use of Hard-Coded Cryptographic Key issue was discovered in Mirion Technologies DMC 3000 Transmitter Module, iPam Transmitter f/DMC 2000, RDS-31 iTX and variants (including RSD31-AM Package), DRM-1/2 and variants (including Solar PWR Package), DRM and RDS Based Boundary Monitors, External Transmitters, Telepole II, and MESH Repeater (Telemetry Enabled Devices). An unchangeable, factory-set key is included in the 900 MHz transmitter firmware. plural Mirion Technologies The product contains a vulnerability related to the use of hard-coded credentials.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Mirion Technologies provides a source of solutions for nuclear, military, radiation detection and monitoring. Mirion Technologies Telemetry Enabled Devices is a denial of service vulnerability that could allow an attacker to transmit fraudulent data or perform denial of service.
Successfully exploiting these issues may allow an attacker to bypass certain security restrictions and perform unauthorized actions. This may aid in further attacks. RSD31-AM Package),
DRM-1/2 and variants (incl. are products of Mirion Technologies in the United States. Mirion Technologies DMC 3000 Transmitter Module is a DMC 3000 series control card
| VAR-201804-0779 | CVE-2017-9656 | Philips DoseWise Portal Vulnerabilities related to the use of hard-coded credentials in applications |
CVSS V2: 6.5 CVSS V3: 9.1 Severity: CRITICAL |
The backend database of the Philips DoseWise Portal application versions 1.1.7.333 and 2.1.1.3069 uses hard-coded credentials for a database account with privileges that can affect confidentiality, integrity, and availability of the database. For an attacker to exploit this vulnerability, elevated privileges are first required for an attacker to access the web application backend system files that contain the hard-coded credentials. Successful exploitation may allow a remote attacker to gain access to the database of the DWP application, which contains PHI. CVSS v3 base score: 9.1, CVSS vector string: AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H. Philips DoseWise Portal The application contains a vulnerability related to the use of hard-coded credentials.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Philips' DoseWise Portal is a web-based reporting and radiation exposure tracking tool. There is a hard-coded vulnerability in Philips' DoseWise Portal.
Attackers can exploit this issue to obtain sensitive information or bypass the authentication mechanism and gain unauthorized access to the device.
DoseWise Portal 1.1.7.333 and 2.1.1.3069 are vulnerable. The platform is used to record, track and analyze radiation exposure to patients and physicians
| VAR-201804-0778 | CVE-2017-9654 | Philips DoseWise Portal of Web Vulnerability related to certificate / password management in base application |
CVSS V2: 4.0 CVSS V3: 8.8 Severity: HIGH |
The Philips DoseWise Portal web-based application versions 1.1.7.333 and 2.1.1.3069 stores login credentials in clear text within backend system files. CVSS v3 base score: 6.5, CVSS vector string: AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N. Philips DoseWise Portal of Web The base application contains a vulnerability related to certificate and password management.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Philips' DoseWise Portal is a web-based reporting and radiation exposure tracking tool. A plaintext storage vulnerability exists in Philips' DoseWise Portal.
Attackers can exploit this issue to obtain sensitive information or bypass the authentication mechanism and gain unauthorized access to the device.
DoseWise Portal 1.1.7.333 and 2.1.1.3069 are vulnerable. The platform is used to record, track and analyze radiation exposure to patients and physicians. A remote attacker could exploit this vulnerability to gain access to the DWP application database
| VAR-201706-0669 | CVE-2017-9675 |
D-Link DIR-605L Vulnerability related to input validation in device firmware
Related entries in the VARIoT exploits database: VAR-E-201711-0123 |
CVSS V2: 7.8 CVSS V3: 7.5 Severity: HIGH |
On D-Link DIR-605L devices, firmware before 2.08UIBetaB01.bin allows an unauthenticated GET request to trigger a reboot. D-Link DIR-605L There is an input validation vulnerability in the device firmware.Service operation interruption (DoS) There is a possibility of being put into a state. D-LinkDIR-605L is a cloud router product from D-Link. A denial of service vulnerability exists in D-LinkDIR-605L with firmware prior to 2.08 UIBetaB01.bin. An attacker could exploit the vulnerability by sending a specially crafted GET request to cause the device to reboot. D-Link DIR-605L is prone to a denial-of-service vulnerability.
Versions prior to D-Link DIR-605L 2.08UIBetaB01.bin are vulnerable
| VAR-201708-1407 | CVE-2017-9660 | Fuji Electric Monitouch V-SFT Buffer error vulnerability |
CVSS V2: 6.8 CVSS V3: 8.8 Severity: HIGH |
A Heap-Based Buffer Overflow was discovered in Fuji Electric Monitouch V-SFT versions prior to Version 5.4.43.0. A heap-based buffer overflow vulnerability has been identified, which may cause a crash or allow remote code execution. Fuji Electric Monitouch V-SFT Contains a buffer error vulnerability.Information is acquired, information is falsified, and denial of service (DoS) May be in a state. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within parsing of a V8 project file. The issue lies in the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. An attacker can leverage this vulnerability to execute arbitrary code under the context of the process. Fuji Electric Monitouch V-SFT is an HMI software. Failed exploit attempts will result in denial-of-service conditions
| VAR-201709-1217 | CVE-2017-7735 | Fortinet FortiOS Vulnerable to cross-site scripting |
CVSS V2: 3.5 CVSS V3: 5.4 Severity: MEDIUM |
A Cross-Site Scripting vulnerability in Fortinet FortiOS versions 5.2.0 through 5.2.11 and 5.4.0 through 5.4.4 allows attackers to execute unauthorized code or commands via the "Groups" input while creating or editing User Groups. Fortinet FortiOS Contains a cross-site scripting vulnerability.Information may be obtained and information may be altered. FortiOS is prone to multiple cross-site scripting vulnerabilities.
An attacker may leverage these issues to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This can allow the attacker to steal cookie-based authentication credentials and launch other attacks. Fortinet FortiOS is a set of security operating systems developed by Fortinet Corporation for the FortiGate network security platform. The system provides users with various security functions such as firewall, anti-virus, IPSec/SSL VPN, Web content filtering and anti-spam
| VAR-201709-1216 | CVE-2017-7734 | Fortinet FortiOS Vulnerable to cross-site scripting |
CVSS V2: 3.5 CVSS V3: 5.4 Severity: MEDIUM |
A Cross-Site Scripting vulnerability in Fortinet FortiOS versions 5.4.0 through 5.4.4 allows attackers to execute unauthorized code or commands via 'Comments' while saving Config Revisions. Fortinet FortiOS Contains a cross-site scripting vulnerability.Information may be obtained and information may be altered. FortiOS is prone to multiple cross-site scripting vulnerabilities.
An attacker may leverage these issues to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This can allow the attacker to steal cookie-based authentication credentials and launch other attacks. Fortinet FortiOS is a set of security operating systems developed by Fortinet Corporation for the FortiGate network security platform. The system provides users with various security functions such as firewall, anti-virus, IPSec/SSL VPN, Web content filtering and anti-spam
| VAR-201706-1109 | No CVE | Hikvision Vehicle Remote Monitoring System CUInfoHandle.php File CUID Parameter SQL Injection Vulnerability |
CVSS V2: 7.8 CVSS V3: - Severity: HIGH |
Hikvision vehicle remote monitoring system is a set of vehicle video network monitoring platform software.
Hikvision vehicle remote monitoring system CUInfoHandle.php file parameter CUID has SQL injection vulnerability. Allows attackers to exploit vulnerabilities to obtain database sensitive information.