VARIoT IoT vulnerabilities database

Affected products: vendor, model and version
CWE format is 'CWE-number'. Threat type can be: remote or local
Look up free text in title and description

VAR-201709-1234 CVE-2017-50137 Moxa SoftCMS Live Viewer SQL Injection Vulnerability CVSS V2: 9.3
CVSS V3: -
Severity: HIGH
MoxaSoftCMSLiveViewer is a video surveillance software designed for industrial automation systems. A SQL injection vulnerability exists in MoxaSoftCMSLiveViewer 1.6 and earlier. An attacker exploits a vulnerability to access SoftCMS without knowing the user's password. Moxa SoftCMS is prone to an SQL-injection vulnerability because it fails to sufficiently sanitize user-supplied input before using it in an SQL query. An attacker can exploit this issue to compromise the application, access or modify data, or exploit latent vulnerabilities in the underlying database. Versions prior to Moxa SoftCMS 1.7 are vulnerable
VAR-201712-0255 CVE-2017-14022 Rockwell Automation FactoryTalk Alarms and Events Denial of service vulnerability CVSS V2: 5.0
CVSS V3: 7.5
Severity: HIGH
An Improper Input Validation issue was discovered in Rockwell Automation FactoryTalk Alarms and Events, Version 2.90 and earlier. An unauthenticated attacker with remote access to a network with FactoryTalk Alarms and Events can send a specially crafted set of packets packet to Port 403/TCP (the history archiver service), causing the service to either stall or terminate. Rockwell Automation is a solution provider for industrial automation, control and information technology. An attacker can exploit this issue to cause denial-of-service condition. FactoryTalk Alarms and Events 2.90 and prior are vulnerable. Rockwell Automation Studio 5000 Logix Designer, FactoryTalk View SE and FactoryTalk Services are all products of Rockwell Automation, USA. Rockwell Automation Studio 5000 Logix Designer is an application program used to configure and maintain the controller; FactoryTalk View SE is a set of human-machine interface software; FactoryTalk Services is a set of production and performance management platform. The following products and versions are affected: Rockwell Automation Studio 5000 Logix Designer 24 and later, FactoryTalk View SE version 5.00, FactoryTalk Services
VAR-201711-1076 CVE-2017-14023 Siemens SIMATIC PCS 7 Denial of service vulnerability CVSS V2: 4.0
CVSS V3: 4.9
Severity: MEDIUM
An Improper Input Validation issue was discovered in Siemens SIMATIC PCS 7 V8.1 prior to V8.1 SP1 with WinCC V7.3 Upd 13, and V8.2 all versions. The improper input validation vulnerability has been identified, which may allow an authenticated remote attacker who is a member of the administrators group to crash services by sending specially crafted messages to the DCOM interface. SIMATIC PCS 7 is a set of distributed process control systems using WinCC from Siemens AG, Germany. Siemens SIMATIC PCS 7 is prone to a denial-of-service vulnerability. Remote attackers may exploit this issue to cause denial-of-service conditions, denying service to legitimate users
VAR-201711-0416 CVE-2017-14029 Trihedral Engineering Limited VTScada DLL Hijacking vulnerability CVSS V2: 9.3
CVSS V3: 7.8
Severity: HIGH
An Uncontrolled Search Path Element issue was discovered in Trihedral VTScada 11.3.03 and prior. The program will execute specially crafted malicious dll files placed on the target machine. Trihedral VTScada Contains a vulnerability related to uncontrolled search path elements.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Trihedral VTScada (formerly known as VTS) is a SCADA system based on the Windows platform provided by Trihedral Engineering of Canada. There are multiple vulnerabilities in Trihedral Engineering Limited VTScada. An attacker could execute arbitrary script code in an affected application or bypass an security restriction to perform an unauthorized operation
VAR-201801-0524 CVE-2017-14030 Moxa MXView Vulnerabilities related to unquoted search paths or elements CVSS V2: 4.6
CVSS V3: 7.8
Severity: HIGH
An issue was discovered in Moxa MXview v2.8 and prior. The unquoted service path escalation vulnerability could allow an authorized user with file access to escalate privileges by inserting arbitrary code into the unquoted service path. Moxa MXView Contains vulnerabilities related to unquoted search paths or elements.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Moxa MXView is a network management software for Moxa's configuration, monitoring and diagnostics of network devices in Industrial Ethernet. A privilege elevation vulnerability exists in Moxa MXview 2.8 and earlier. Moxa MXview is prone to a local privilege-escalation vulnerability. Attackers can exploit this issue to execute arbitrary code with elevated privileges
VAR-201709-0364 CVE-2017-14116 AT&T U-verse Vulnerability in using hardcoded credentials in firmware CVSS V2: 9.3
CVSS V3: 8.1
Severity: HIGH
The AT&T U-verse 9.2.2h0d83 firmware for the Arris NVG599 device, when IP Passthrough mode is not used, configures WAN access to a caserver https service with the tech account and an empty password, which allows remote attackers to obtain root privileges by establishing a session on port 49955 and then installing new software, such as BusyBox with "nc -l" support. AT&T U-verse The firmware contains a vulnerability involving the use of hard-coded credentials.Information is acquired, information is falsified, and denial of service (DoS) May be in a state. AT&T U-verse Arris Modems are prone to following security vulnerabilities: 1. An Hardcoded Credential Security Bypass vulnerability. 2. An information-disclosure vulnerability 3. A command injection vulnerability 4. A security-bypass vulnerability Attackers can exploit these issues to obtain sensitive information, execute arbitrary code and perform unauthorized actions., which may aid in further attacks. Failed exploit attempts may result in a denial-of-service condition. Arris NVG599 is a router product of American Arris Group Company. AT&T U-verse is the firmware used in it
VAR-201709-0365 CVE-2017-14117 AT&T U-verse Firmware authentication vulnerability CVSS V2: 4.3
CVSS V3: 5.9
Severity: MEDIUM
The AT&T U-verse 9.2.2h0d83 firmware for the Arris NVG589 and NVG599 devices, when IP Passthrough mode is not used, configures an unauthenticated proxy service on WAN TCP port 49152, which allows remote attackers to establish arbitrary TCP connections to intranet hosts by sending \x2a\xce\x01 followed by other predictable values. AT&T U-verse There are authentication vulnerabilities in the firmware.Information may be tampered with. ArrisNVG589 and NVG599 are router products of Arris Group of the United States. AT&TU-verse is the firmware used in it. A security vulnerability exists in the AT&TU-verse9.2.2h0d83 version of ArrisNVG589 and NVG599. A remote attacker can exploit this vulnerability to establish an arbitrary TCP connection with an internal host. AT&T U-verse Arris Modems are prone to following security vulnerabilities: 1. 2. An information-disclosure vulnerability 3. A command injection vulnerability 4. A security-bypass vulnerability Attackers can exploit these issues to obtain sensitive information, execute arbitrary code and perform unauthorized actions., which may aid in further attacks. Failed exploit attempts may result in a denial-of-service condition
VAR-201709-0219 CVE-2017-10850 In multiple products manufactured by Fuji Xerox Co., Ltd.  DLL  Read vulnerability CVSS V2: 9.3
CVSS V3: 7.8
Severity: HIGH
Untrusted search path vulnerability in Installers of ART EX Driver for ApeosPort-VI C7771/C6671/C5571/C4471/C3371/C2271, DocuCentre-VI C7771/C6671/C5571/C4471/C3371/C2271 (Timestamp of code signing is before 12 Apr 2017 02:04 UTC.), PostScript? Driver + Additional Feature Plug-in + PPD File for ApeosPort-VI C7771/C6671/C5571/C4471/C3371/C2271, DocuCentre-VI C7771/C6671/C5571/C4471/C3371/C2271 (Timestamp of code signing is before 12 Apr 2017 02:10 UTC.), XPS Print Driver for ApeosPort-VI C7771/C6671/C5571/C4471/C3371/C2271, DocuCentre-VI C7771/C6671/C5571/C4471/C3371/C2271 (Timestamp of code signing is before 3 Nov 2017 23:48 UTC.), ART EX Direct FAX Driver for ApeosPort-VI C7771/C6671/C5571/C4471/C3371/C2271, DocuCentre-VI C7771/C6671/C5571/C4471/C3371/C2271 (Timestamp of code signing is before 26 May 2017 07:44 UTC.), Setting Restore Tool for ApeosPort-VI C7771/C6671/C5571/C4471/C3371/C2271, DocuCentre-VI C7771/C6671/C5571/C4471/C3371/C2271 (Timestamp of code signing is before 25 Aug 2015 08:51 UTC.) allows an attacker to gain privileges via a Trojan horse DLL in an unspecified directory. Installers for multiple products provided by Fuji Xerox Co., Ltd. DocuWorks For self-extracting documents, DLL There is a problem with the search path when reading or executing a self-extracting document, which is unintended. DLL Reading vulnerability (CWE-427) Exists. This vulnerability information is based on the Information Security Early Warning Partnership. IPA Report to JPCERT/CC Coordinated with the developers. Reporter : Tachibana Research Institute Hidetoshi Masami MrThe expected impact depends on each vulnerability, but it may be affected as follows. -Arbitrary code is executed with administrator privileges when the installer is started. - CVE-2017-10848, CVE-2017-10850, CVE-2017-10851 ・ DocuWorks Arbitrary code is executed with the authority of the user who executed the self-extracting document - CVE-2017-10849. FujiXeroxDocuCentre-VI and ApeosPort-VI are digital copier PCL print drivers. There are several untrusted search path vulnerabilities in the FujiXerox product installer. Allows an attacker to gain privileges by logging in an unknown Trojan DLL directory
VAR-201711-0411 CVE-2017-14021 Korenix JetNet Man-in-the-middle attack vulnerability CVSS V2: 10.0
CVSS V3: 9.8
Severity: CRITICAL
A Use of Hard-coded Cryptographic Key issue was discovered in Korenix JetNet JetNet5018G version 1.4, JetNet5310G version 1.4a, JetNet5428G-2G-2FX version 1.4, JetNet5628G-R version 1.4, JetNet5628G version 1.4, JetNet5728G-24P version 1.4, JetNet5828G version 1.1d, JetNet6710G-HVDC version 1.1e, and JetNet6710G version 1.1. An attacker may gain access to hard-coded certificates and private keys allowing the attacker to perform man-in-the-middle attacks. plural Korenix JetNet The product contains a vulnerability related to the use of hard-coded credentials.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. JetNet is a series of industrial Ethernet switch products from Koloris. Korenix JetNet is prone to a hard-coded cryptographic key vulnerability and security-bypass vulnerability. An attacker can exploit these issues to bypass the security mechanism and perform unauthorized actions or perform man-in-the middle attacks and obtain sensitive information. This may aid in further attacks. Korenix JetNet JetNet5018G etc
VAR-201711-0414 CVE-2017-14027 Korenix JetNet Unauthorized Access Vulnerability CVSS V2: 10.0
CVSS V3: 9.8
Severity: CRITICAL
A Use of Hard-coded Credentials issue was discovered in Korenix JetNet JetNet5018G version 1.4, JetNet5310G version 1.4a, JetNet5428G-2G-2FX version 1.4, JetNet5628G-R version 1.4, JetNet5628G version 1.4, JetNet5728G-24P version 1.4, JetNet5828G version 1.1d, JetNet6710G-HVDC version 1.1e, and JetNet6710G version 1.1. The software uses undocumented hard-coded credentials that may allow an attacker to gain remote access. plural Korenix JetNet The product contains a vulnerability related to the use of hard-coded credentials.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. JetNet is a series of industrial Ethernet switch products from Koloris. Korenix JetNet is prone to a hard-coded cryptographic key vulnerability and security-bypass vulnerability. An attacker can exploit these issues to bypass the security mechanism and perform unauthorized actions or perform man-in-the middle attacks and obtain sensitive information. This may aid in further attacks. Korenix JetNet JetNet5018G etc. A security vulnerability exists in several Korenix products due to the program's use of hard-coded certificates
VAR-201709-0363 CVE-2017-14115 AT&T U-verse Firmware access control vulnerability CVSS V2: 9.3
CVSS V3: 8.1
Severity: HIGH
The AT&T U-verse 9.2.2h0d83 firmware for the Arris NVG589 and NVG599 devices, when IP Passthrough mode is not used, configures ssh-permanent-enable WAN SSH logins to the remotessh account with the 5SaP9I26 password, which allows remote attackers to access a "Terminal shell v1.0" service, and subsequently obtain unrestricted root privileges, by establishing an SSH session and then entering certain shell metacharacters and BusyBox commands. AT&T U-verse The firmware contains a vulnerability related to access control.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. ArrisNVG589 and NVG599 are router products of Arris Group of the United States. AT&TU-verse is the firmware used in it. A security vulnerability exists in the AT&TU-verse9.2.2h0d83 version of ArrisNVG589 and NVG599. AT&T U-verse Arris Modems are prone to following security vulnerabilities: 1. 2. An information-disclosure vulnerability 3. A command injection vulnerability 4. A security-bypass vulnerability Attackers can exploit these issues to obtain sensitive information, execute arbitrary code and perform unauthorized actions., which may aid in further attacks. Failed exploit attempts may result in a denial-of-service condition
VAR-201711-0415 CVE-2017-14028 plural Moxa NPort Product depletion vulnerability CVSS V2: 5.0
CVSS V3: 7.5
Severity: HIGH
A Resource Exhaustion issue was discovered in Moxa NPort 5110 Version 2.2, NPort 5110 Version 2.4, NPort 5110 Version 2.6, NPort 5110 Version 2.7, NPort 5130 Version 3.7 and prior, and NPort 5150 Version 3.7 and prior. An attacker may be able to exhaust memory resources by sending a large amount of TCP SYN packets. plural Moxa NPort The product is vulnerable to resource exhaustion.Service operation interruption (DoS) There is a possibility of being put into a state. Moxa's NPort 5110, 5130 and 5150 are all Moxa's serial communication servers for connecting industrial serial devices to the network. Multiple Moxa NPort products are prone to multiple denial-of-service vulnerabilities and an information-disclosure vulnerability. An attacker can exploit these issues to obtain sensitive information or cause excessive consumption of resources or crash of application resulting in a denial of service condition. A security vulnerability exists in the Moxa NPort 5110, 5130, and 5150
VAR-201711-0413 CVE-2017-14025 ABB FOX515T Information Disclosure Vulnerability CVSS V2: 2.1
CVSS V3: 5.5
Severity: MEDIUM
An Improper Input Validation issue was discovered in ABB FOX515T release 1.0. An improper input validation vulnerability has been identified, allowing a local attacker to provide a malicious parameter to the script that is not validated by the application, This could enable the attacker to retrieve any file on the server. FOX515 is a universal communication platform based on TDM technology (time division multiplexing). ABB FOX515T is prone to a local information-disclosure vulnerability. Successful exploits may allow an attacker to obtain sensitive information that may lead to further attacks. ABB FOX515T 1.0 is vulnerable; other versions may also be affected. ABB FOX515T is a multi-functional optical transmission equipment produced by Swiss ABB company
VAR-201710-0804 CVE-2017-14017 Progea Movicon SCADA/HMI Arbitrary code execution vulnerability

Related entries in the VARIoT exploits database: VAR-E-201710-0246
CVSS V2: 4.6
CVSS V3: 7.8
Severity: HIGH
An Uncontrolled Search Path Element issue was discovered in Progea Movicon Version 11.5.1181 and prior. An uncontrolled search path element vulnerability has been identified, which may allow a remote attacker without privileges to execute arbitrary code in the form of a malicious DLL file. Progea Movicon Contains a vulnerability related to uncontrolled search path elements.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Movicon is an industrial monitoring software developed by the Italian automation software provider PROGEA (Scada/HMI). Progea Movicon is prone to a multiple privilege-escalation vulnerabilities. Movicon versions 11.5.1181 and prior are affected. ------------------------ BACKGROUND ------------------------ Critical Infrastructure Sectors: Critical Manufacturing, Energy, Food and Agriculture, Transportation Systems, Water and Wastewater Systems Countries/Areas Deployed: Europe, India, and United States Company Headquarters Location: Italy ------------------------ IMPACT ------------------------ Successful exploitation of these vulnerabilities could allow privilege escalation or arbitrary code execution. The specific flaw exists within the handling of a specific named DLL file used by Movicon SCADA/HMI. By placing specific DLL file (listed below), an attacker is able to force the process to load an arbitrary DLL. ------------------------ DLL File Name (1) ------------------------ api-ms-win-appmodel-runtime-l1-1-0.dll ------------------------ Application Executables (that look for missing DLL) ------------------------ Movicon.exe MoviconRunTime.exe MoviconService.exe AlarmsImpExp.exe ReportViewerNET.exe ------------------------ Steps to reproduce ------------------------ 1. Generate a dll payload msfvenom ap windows/exec cmd=calc.exe af dll ao api-ms-win-appmodel-runtime-l1-1-0.dll 2. Place this dll in install directory (or C:\Windows, or any directory defined in the PATH environment variable) C:\Program Files\Progea\Movicon11.5\ 3. Run MoviconService.exe (or any of the above listed executables), and Exit ------------------------ CVE-2017-14017 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H). A successful attempt would require the local user to be able to insert their code in the system root path undetected by the OS or other security applications where it could potentially be executed during application startup or reboot. aC/ MOVICON (MOVICON) runs as LocalSystem and has path: C:\Program Files\Progea\Movicon11.5\MoviconService.exe: CVE-2017-14019 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H). +++++ Best Regards, Karn Ganeshen
VAR-201710-0805 CVE-2017-14019 Progea Movicon Vulnerabilities related to unquoted search paths or elements

Related entries in the VARIoT exploits database: VAR-E-201710-0246
CVSS V2: 4.6
CVSS V3: 6.7
Severity: MEDIUM
An Unquoted Search Path or Element issue was discovered in Progea Movicon Version 11.5.1181 and prior. An unquoted search path or element vulnerability has been identified, which may allow an authorized local user to insert arbitrary code into the unquoted service path and escalate his or her privileges. Progea Movicon Contains vulnerabilities related to unquoted search paths or elements.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Movicon is an industrial monitoring software developed by the Italian automation software provider PROGEA (Scada/HMI). Progea Movicon is prone to a multiple privilege-escalation vulnerabilities. An attacker can exploit these issues to execute arbitrary code to gain elevated privileges. Movicon versions 11.5.1181 and prior are affected. ------------------------ BACKGROUND ------------------------ Critical Infrastructure Sectors: Critical Manufacturing, Energy, Food and Agriculture, Transportation Systems, Water and Wastewater Systems Countries/Areas Deployed: Europe, India, and United States Company Headquarters Location: Italy ------------------------ IMPACT ------------------------ Successful exploitation of these vulnerabilities could allow privilege escalation or arbitrary code execution. User interaction is required to exploit this vulnerability in that the malicious dll file should be saved in any of the DLL search paths. The specific flaw exists within the handling of a specific named DLL file used by Movicon SCADA/HMI. By placing specific DLL file (listed below), an attacker is able to force the process to load an arbitrary DLL. ------------------------ DLL File Name (1) ------------------------ api-ms-win-appmodel-runtime-l1-1-0.dll ------------------------ Application Executables (that look for missing DLL) ------------------------ Movicon.exe MoviconRunTime.exe MoviconService.exe AlarmsImpExp.exe ReportViewerNET.exe ------------------------ Steps to reproduce ------------------------ 1. Generate a dll payload msfvenom ap windows/exec cmd=calc.exe af dll ao api-ms-win-appmodel-runtime-l1-1-0.dll 2. Place this dll in install directory (or C:\Windows, or any directory defined in the PATH environment variable) C:\Program Files\Progea\Movicon11.5\ 3. Run MoviconService.exe (or any of the above listed executables), and Exit ------------------------ CVE-2017-14017 has been assigned to this vulnerability. A CVSS v3 base score of 6.8 has been assigned; the CVSS vector string is (AV:N/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H). A successful attempt would require the local user to be able to insert their code in the system root path undetected by the OS or other security applications where it could potentially be executed during application startup or reboot. aC/ MOVICON (MOVICON) runs as LocalSystem and has path: C:\Program Files\Progea\Movicon11.5\MoviconService.exe: CVE-2017-14019 has been assigned to this vulnerability. A CVSS v3 base score of 6.5 has been assigned; the CVSS vector string is (AV:L/AC:L/PR:H/UI:R/S:U/C:H/I:H/A:H). +++++ Best Regards, Karn Ganeshen
VAR-201711-0417 CVE-2017-14031 Trihedral Engineering Limited VTScada Unauthorized Access Vulnerability CVSS V2: 7.2
CVSS V3: 7.8
Severity: HIGH
An Improper Access Control issue was discovered in Trihedral VTScada 11.3.03 and prior. A local, non-administrator user has privileges to read and write to the file system of the target machine. Trihedral VTScada Contains an access control vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Trihedral VTScada (formerly known as VTS) is a SCADA system based on the Windows platform provided by Trihedral Engineering of Canada. There are multiple vulnerabilities in Trihedral Engineering Limited VTScada. An attacker could execute arbitrary script code in an affected application or bypass an security restriction to perform an unauthorized operation
VAR-201708-0476 CVE-2017-12069 Siemens OPC UA protocol XML External entity vulnerability CVSS V2: 6.4
CVSS V3: 8.2
Severity: HIGH
An XXE vulnerability has been identified in OPC Foundation UA .NET Sample Code before 2017-03-21 and Local Discovery Server (LDS) before 1.03.367. Among the affected products are Siemens SIMATIC PCS7 (All versions V8.1 and earlier), SIMATIC WinCC (All versions < V7.4 SP1), SIMATIC WinCC Runtime Professional (All versions < V14 SP1), SIMATIC NET PC Software, and SIMATIC IT Production Suite. By sending specially crafted packets to the OPC Discovery Server at port 4840/tcp, an attacker might cause the system to access various resources chosen by the attacker. Siemens industrial products are based on the OPC UAP protocol based on OPC to discover and configure LAN device information. The Siemens OPC UA protocol has an XML external entity vulnerability. Attackers can exploit this issue to gain access to sensitive information or cause denial-of-service conditions. Siemens SIMATIC PCS and so on are all products of German Siemens (Siemens). Siemens SIMATIC PCS is a process control system. SIMATIC WinCC is a set of automatic data acquisition and monitoring (SCADA) system
VAR-201709-1007 CVE-2017-12731 plural OPW Fuel Management Systems SiteSentinel In product SQL Injection vulnerability CVSS V2: 7.5
CVSS V3: 9.8
Severity: CRITICAL
A SQL Injection issue was discovered in OPW Fuel Management Systems SiteSentinel Integra 100, SiteSentinel Integra 500, and SiteSentinel iSite ATG consoles with the following software versions: older than V175, V175-V189, V191-V195, and V16Q3.1. The application is vulnerable to injection of malicious SQL queries via the input from the client. Multiple OPW Products are prone to an SQL-injection vulnerability and an authentication-bypass vulnerability. An attacker can exploit these issues to bypass certain security restrictions, perform unauthorized actions, modify the logic of SQL queries, compromise the software, retrieve information, or modify data; other consequences are possible as well. SQL injection vulnerabilities exist in multi-span OPWA products
VAR-201708-1136 CVE-2017-12734 Siemens LOGO! Information disclosure vulnerability in devices CVSS V2: 5.0
CVSS V3: 7.5
Severity: HIGH
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V1.81.2). An attacker with network access to the integrated web server on port 80/tcp could obtain the session ID of an active user session. A user must be logged in to the web interface. Siemens recommends to use the integrated webserver on port 80/tcp only in trusted networks. Siemens LOGO! The device contains an information disclosure vulnerability.Information may be obtained. LOGO!8 is the 8th generation intelligent logic controller of Siemens. It is the NanoPLC in the Siemens PLC family. It simplifies the programming configuration, the integrated panel can display more content, and can be easily integrated efficiently through the integrated Ethernet interface. interconnected. There is a vulnerability in SiemensLOGO!8BM. An attacker can exploit this issue to obtain sensitive information. Successful exploits may lead to other attacks. Versions prior to LOGO!8 BM FS-05 1.81.2 are vulnerable
VAR-201708-1137 CVE-2017-12735 Siemens LOGO!8 BM Man-in-the-middle attack vulnerability CVSS V2: 5.8
CVSS V3: 7.4
Severity: HIGH
A vulnerability has been identified in LOGO! 8 BM (incl. SIPLUS variants) (All versions < V8.3). An attacker who performs a Man-in-the-Middle attack between the LOGO! BM and other devices could potentially decrypt and modify network traffic. Siemens LOGO! The device contains an access control vulnerability.Information may be obtained and information may be altered. LOGO!8 is the 8th generation intelligent logic controller of Siemens. It is the NanoPLC in the Siemens PLC family. It simplifies the programming configuration, the integrated panel can display more content, and can be easily integrated efficiently through the integrated Ethernet interface. interconnected. Successfully exploiting this issue may allow attackers to bypass certain security restrictions and perform unauthorized actions by conducting a man-in-the-middle attack. This may lead to other attacks