VARIoT IoT vulnerabilities database

Affected products: vendor, model and version
CWE format is 'CWE-number'. Threat type can be: remote or local
Look up free text in title and description

VAR-201710-1405 CVE-2017-7092 plural Apple Used in products WebKit Vulnerable to arbitrary code execution CVSS V2: 6.8
CVSS V3: 8.8
Severity: HIGH
An issue was discovered in certain Apple products. iOS before 11 is affected. Safari before 11 is affected. iCloud before 7.0 on Windows is affected. iTunes before 12.7 on Windows is affected. tvOS before 11 is affected. The issue involves the "WebKit" component. It allows remote attackers to execute arbitrary code or cause a denial of service (memory corruption and application crash) via a crafted web site. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the handling of the String.link method. The issue results from the lack of proper validation of user-supplied data, which can result in an integer overflow before allocating a buffer. An attacker can leverage this vulnerability to execute code under the context of the current process. WebKit is prone to multiple memory-corruption vulnerabilities. These issues affect the following technologies and versions: iCloud for Windows 7 Safari prior to 11 tvOS prior to 11 iTunes for Windows prior to 12.7. Apple iOS is an operating system developed for mobile devices; Safari is a web browser that is the default browser included with Mac OS X and iOS operating systems. WebKit is one of the web browser engine components. A security vulnerability exists in the WebKit component of several Apple products. Installation note: Safari 11 may be obtained from the Mac App Store. ------------------------------------------------------------------------ WebKitGTK+ Security Advisory WSA-2017-0008 ------------------------------------------------------------------------ Date reported : October 18, 2017 Advisory ID : WSA-2017-0008 Advisory URL : https://webkitgtk.org/security/WSA-2017-0008.html CVE identifiers : CVE-2017-7081, CVE-2017-7087, CVE-2017-7089, CVE-2017-7090, CVE-2017-7091, CVE-2017-7092, CVE-2017-7093, CVE-2017-7094, CVE-2017-7095, CVE-2017-7096, CVE-2017-7098, CVE-2017-7099, CVE-2017-7100, CVE-2017-7102, CVE-2017-7104, CVE-2017-7107, CVE-2017-7109, CVE-2017-7111, CVE-2017-7117, CVE-2017-7120, CVE-2017-7142. Several vulnerabilities were discovered in WebKitGTK+. Credit to Apple. Description: A memory corruption issue was addressed through improved input validation. Credit to Apple. Description: Multiple memory corruption issues were addressed with improved memory handling. Credit to Anton Lopanitsyn of ONSEC, Frans RosA(c)n of Detectify. Impact: Processing maliciously crafted web content may lead to universal cross site scripting. Description: A logic issue existed in the handling of the parent-tab. This issue was addressed with improved state management. Credit to Apple. Impact: Cookies belonging to one origin may be sent to another origin. Description: A permissions issue existed in the handling of web browser cookies. This issue was addressed by no longer returning cookies for custom URL schemes. Credit to Wei Yuan of Baidu Security Lab working with Trend Microas Zero Day Initiative. Description: Multiple memory corruption issues were addressed with improved memory handling. Credit to Qixun Zhao (@S0rryMybad) of Qihoo 360 Vulcan Team, Samuel Gro and Niklas Baumstark working with Trend Micro's Zero Day Initiative. Description: Multiple memory corruption issues were addressed with improved memory handling. Credit to Samuel Gro and Niklas Baumstark working with Trend Microas Zero Day Initiative. Description: Multiple memory corruption issues were addressed with improved memory handling. Credit to Tim Michaud (@TimGMichaud) of Leviathan Security Group. Description: Multiple memory corruption issues were addressed with improved memory handling. Credit to Wang Junjie, Wei Lei, and Liu Yang of Nanyang Technological University working with Trend Microas Zero Day Initiative. Description: Multiple memory corruption issues were addressed with improved memory handling. Credit to Wei Yuan of Baidu Security Lab. Description: Multiple memory corruption issues were addressed with improved memory handling. Credit to Felipe Freitas of Instituto TecnolA3gico de AeronA!utica. Description: Multiple memory corruption issues were addressed with improved memory handling. Credit to Apple. Description: Multiple memory corruption issues were addressed with improved memory handling. Credit to Masato Kinugawa and Mario Heiderich of Cure53. Description: Multiple memory corruption issues were addressed with improved memory handling. Credit to Wang Junjie, Wei Lei, and Liu Yang of Nanyang Technological University. Description: Multiple memory corruption issues were addressed with improved memory handling. Credit to likemeng of Baidu Secutity Lab. Description: Multiple memory corruption issues were addressed with improved memory handling. Credit to Wang Junjie, Wei Lei, and Liu Yang of Nanyang Technological University. Description: Multiple memory corruption issues were addressed with improved memory handling. Credit to avlidienbrunn. Impact: Processing maliciously crafted web content may lead to a cross site scripting attack. Description: Application Cache policy may be unexpectedly applied. Credit to likemeng of Baidu Security Lab (xlab.baidu.com) working with Trend Micro's Zero Day Initiative. Description: Multiple memory corruption issues were addressed with improved memory handling. Credit to lokihardt of Google Project Zero. Description: Multiple memory corruption issues were addressed with improved memory handling. Credit to chenqin (ee|) of Ant-financial Light-Year Security Lab. Description: Multiple memory corruption issues were addressed with improved memory handling. Credit to an anonymous researcher. Impact: Website data may persist after a Safari Private browsing session. Description: An information leakage issue existed in the handling of website data in Safari Private windows. This issue was addressed with improved data handling. We recommend updating to the last stable version of WebKitGTK+. It is the best way of ensuring that you are running a safe version of WebKitGTK+. Please check our website for information about the last stable releases. Further information about WebKitGTK+ Security Advisories can be found at: https://webkitgtk.org/security.html The WebKitGTK+ team, October 18, 2017 . ========================================================================== Ubuntu Security Notice USN-3460-1 October 23, 2017 webkit2gtk vulnerabilities ========================================================================== A security issue affects these releases of Ubuntu and its derivatives: - Ubuntu 17.04 - Ubuntu 16.04 LTS Summary: Several security issues were fixed in WebKitGTK+. Software Description: - webkit2gtk: Web content engine library for GTK+ Details: A large number of security issues were discovered in the WebKitGTK+ Web and JavaScript engines. Update instructions: The problem can be corrected by updating your system to the following package versions: Ubuntu 17.04: libjavascriptcoregtk-4.0-18 2.18.0-0ubuntu0.17.04.2 libwebkit2gtk-4.0-37 2.18.0-0ubuntu0.17.04.2 Ubuntu 16.04 LTS: libjavascriptcoregtk-4.0-18 2.18.0-0ubuntu0.16.04.2 libwebkit2gtk-4.0-37 2.18.0-0ubuntu0.16.04.2 This update uses a new upstream release, which includes additional bug fixes. After a standard system update you need to restart any applications that use WebKitGTK+, such as Epiphany, to make all the necessary changes. References: https://www.ubuntu.com/usn/usn-3460-1 CVE-2017-7087, CVE-2017-7089, CVE-2017-7090, CVE-2017-7091, CVE-2017-7092, CVE-2017-7093, CVE-2017-7095, CVE-2017-7096, CVE-2017-7098, CVE-2017-7100, CVE-2017-7102, CVE-2017-7104, CVE-2017-7107, CVE-2017-7109, CVE-2017-7111, CVE-2017-7117, CVE-2017-7120 Package Information: https://launchpad.net/ubuntu/+source/webkit2gtk/2.18.0-0ubuntu0.17.04.2 https://launchpad.net/ubuntu/+source/webkit2gtk/2.18.0-0ubuntu0.16.04.2 . -----BEGIN PGP SIGNED MESSAGE----- Hash: SHA512 APPLE-SA-2017-09-25-4 Additional information for APPLE-SA-2017-09-19-1 iOS 11 iOS 11 addresses the following: Bluetooth Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: An application may be able to access restricted files Description: A privacy issue existed in the handling of Contact cards. CVE-2017-7131: Dominik Conrads of Federal Office for Information Security, an anonymous researcher, Elvis (@elvisimprsntr), an anonymous researcher Entry added September 25, 2017 CFNetwork Proxies Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: An attacker in a privileged network position may be able to cause a denial of service Description: Multiple denial of service issues were addressed through improved memory handling. CVE-2017-7083: Abhinav Bansal of Zscaler Inc. Entry added September 25, 2017 CoreAudio Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: An application may be able to read restricted memory Description: An out-of-bounds read was addressed by updating to Opus version 1.1.4. CVE-2017-0381: V.E.O (@VYSEa) of Mobile Threat Research Team, Trend Micro Entry added September 25, 2017 Exchange ActiveSync Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: An attacker in a privileged network position may be able to erase a device during Exchange account setup Description: A validation issue existed in AutoDiscover V1. This was addressed by requiring TLS for AutoDiscover V1. AutoDiscover V2 is now supported. CVE-2017-7088: Ilya Nesterov, Maxim Goncharov Heimdal Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: An attacker in a privileged network position may be able to impersonate a service Description: A validation issue existed in the handling of the KDC- REP service name. CVE-2017-11103: Jeffrey Altman, Viktor Duchovni, and Nico Williams Entry added September 25, 2017 iBooks Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: Parsing a maliciously crafted iBooks file may lead to a persistent denial-of-service Description: Multiple denial of service issues were addressed through improved memory handling. CVE-2017-7072: JAdrzej Krysztofiak Entry added September 25, 2017 Kernel Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: An application may be able to execute arbitrary code with kernel privileges Description: A memory corruption issue was addressed with improved memory handling. CVE-2017-7114: Alex Plaskett of MWR InfoSecurity Entry added September 25, 2017 Keyboard Suggestions Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: Keyboard autocorrect suggestions may reveal sensitive information Description: The iOS keyboard was inadvertently caching sensitive information. CVE-2017-7140: an anonymous researcher Entry added September 25, 2017 libc Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: A remote attacker may be able to cause a denial-of-service Description: A resource exhaustion issue in glob() was addressed through an improved algorithm. CVE-2017-7086: Russ Cox of Google Entry added September 25, 2017 libc Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: An application may be able to cause a denial of service Description: A memory consumption issue was addressed through improved memory handling. CVE-2017-1000373 Entry added September 25, 2017 libexpat Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: Multiple issues in expat Description: Multiple issues were addressed by updating to version 2.2.1 CVE-2016-9063 CVE-2017-9233 Entry added September 25, 2017 Location Framework Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: An application may be able to read sensitive location information Description: A permissions issue existed in the handling of the location variable. This was addressed with additional ownership checks. CVE-2017-7148: an anonymous researcher, an anonymous researcher Entry added September 25, 2017 Mail Drafts Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: An attacker with a privileged network position may be able to intercept mail contents Description: An encryption issue existed in the handling of mail drafts. CVE-2017-7078: an anonymous researcher, an anonymous researcher, an anonymous researcher Entry added September 25, 2017 Mail MessageUI Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: Processing a maliciously crafted image may lead to a denial of service Description: A memory corruption issue was addressed with improved validation. CVE-2017-7097: Xinshu Dong and Jun Hao Tan of Anquan Capital Messages Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: Processing a maliciously crafted image may lead to a denial of service Description: A denial of service issue was addressed through improved validation. CVE-2017-7118: Kiki Jiang and Jason Tokoph MobileBackup Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: Backup may perform an unencrypted backup despite a requirement to perform only encrypted backups Description: A permissions issue existed. CVE-2017-7133: Don Sparks of HackediOS.com Phone Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: A screenshot of secure content may be taken when locking an iOS device Description: A timing issue existed in the handling of locking. CVE-2017-7139: an anonymous researcher Entry added September 25, 2017 Safari Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: Visiting a malicious website may lead to address bar spoofing Description: An inconsistent user interface issue was addressed with improved state management. CVE-2017-7085: xisigr of Tencent's Xuanwu Lab (tencent.com) Security Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: A revoked certificate may be trusted Description: A certificate validation issue existed in the handling of revocation data. CVE-2017-7080: an anonymous researcher, an anonymous researcher, Sven Driemecker of adesso mobile solutions gmbh, Rune Darrud (@theflyingcorpse) of BA|rum kommune Entry added September 25, 2017 Security Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: A malicious app may be able to track users between installs Description: A permission checking issue existed in the handling of an app's Keychain data. CVE-2017-7146: an anonymous researcher Entry added September 25, 2017 SQLite Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: Multiple issues in SQLite Description: Multiple issues were addressed by updating to version 3.19.3. CVE-2017-10989: found by OSS-Fuzz CVE-2017-7128: found by OSS-Fuzz CVE-2017-7129: found by OSS-Fuzz CVE-2017-7130: found by OSS-Fuzz Entry added September 25, 2017 SQLite Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: An application may be able to execute arbitrary code with system privileges Description: A memory corruption issue was addressed with improved memory handling. CVE-2017-7127: an anonymous researcher Entry added September 25, 2017 Time Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: "Setting Time Zone" may incorrectly indicate that it is using location Description: A permissions issue existed in the process that handles time zone information. The issue was resolved by modifying permissions. CVE-2017-7145: an anonymous researcher Entry added September 25, 2017 WebKit Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: Processing maliciously crafted web content may lead to arbitrary code execution Description: A memory corruption issue was addressed through improved input validation. CVE-2017-7081: Apple Entry added September 25, 2017 WebKit Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: Processing maliciously crafted web content may lead to arbitrary code execution Description: Multiple memory corruption issues were addressed with improved memory handling. CVE-2017-7089: Anton Lopanitsyn of ONSEC, Frans RosA(c)n of Detectify Entry added September 25, 2017 WebKit Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: Cookies belonging to one origin may be sent to another origin Description: A permissions issue existed in the handling of web browser cookies. CVE-2017-7090: Apple Entry added September 25, 2017 WebKit Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: Visiting a malicious website may lead to address bar spoofing Description: An inconsistent user interface issue was addressed with improved state management. CVE-2017-7109: avlidienbrunn Entry added September 25, 2017 WebKit Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: A malicious website may be able to track users in Safari private browsing mode Description: A permissions issue existed in the handling of web browser cookies. CVE-2017-7144: an anonymous researcher Entry added September 25, 2017 Wi-Fi Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: An attacker within range may be able to execute arbitrary code on the Wi-Fi chip Description: A memory corruption issue was addressed with improved memory handling. CVE-2017-11120: Gal Beniamini of Google Project Zero CVE-2017-11121: Gal Beniamini of Google Project Zero Entry added September 25, 2017 Wi-Fi Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: Malicious code executing on the Wi-Fi chip may be able to execute arbitrary code with kernel privileges on the application processor Description: A memory corruption issue was addressed with improved memory handling. CVE-2017-7103: Gal Beniamini of Google Project Zero CVE-2017-7105: Gal Beniamini of Google Project Zero CVE-2017-7108: Gal Beniamini of Google Project Zero CVE-2017-7110: Gal Beniamini of Google Project Zero CVE-2017-7112: Gal Beniamini of Google Project Zero Wi-Fi Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: Malicious code executing on the Wi-Fi chip may be able to execute arbitrary code with kernel privileges on the application processor Description: Multiple race conditions were addressed through improved validation. CVE-2017-7115: Gal Beniamini of Google Project Zero Wi-Fi Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: Malicious code executing on the Wi-Fi chip may be able to read restricted kernel memory Description: A validation issue was addressed with improved input sanitization. CVE-2017-7116: Gal Beniamini of Google Project Zero zlib Available for: iPhone 5s and later, iPad Air and later, and iPod touch 6th generation Impact: Multiple issues in zlib Description: Multiple issues were addressed by updating to version 1.2.11. CVE-2016-9840 CVE-2016-9841 CVE-2016-9842 CVE-2016-9843 Entry added September 25, 2017 Additional recognition Security We would like to acknowledge Abhinav Bansal of Zscaler, Inc. for their assistance. Webkit We would like to acknowledge xisigr of Tencent's Xuanwu Lab (tencent.com) for their assistance. Installation note: This update is available through iTunes and Software Update on your iOS device, and will not appear in your computer's Software Update application, or in the Apple Downloads site. Make sure you have an Internet connection and have installed the latest version of iTunes from https://www.apple.com/itunes/ iTunes and Software Update on the device will automatically check Apple's update server on its weekly schedule. When an update is detected, it is downloaded and the option to be installed is presented to the user when the iOS device is docked. We recommend applying the update immediately if possible. Selecting Don't Install will present the option the next time you connect your iOS device. The automatic update process may take up to a week depending on the day that iTunes or the device checks for updates. You may manually obtain the update via the Check for Updates button within iTunes, or the Software Update on your device. To check that the iPhone, iPod touch, or iPad has been updated: * Navigate to Settings * Select General * Select About. Information will also be posted to the Apple Security Updates web site: https://support.apple.com/kb/HT201222 This message is signed with Apple's Product Security PGP key, and details are available at: https://www.apple.com/support/security/pgp/ -----BEGIN PGP SIGNATURE----- Comment: GPGTools - https://gpgtools.org iQIcBAEBCgAGBQJZyUQfAAoJEIOj74w0bLRGvBgQAJIF/+cKGy/7YWEugFrwr8A3 rNzHU/yZ3X976fmlYM8l+VUJEn2khu5huPsQzYUvEdbHOWkUGThKil+NzDr3YP6V YYRIi+6i9KJEATGQAdR9YW6bcqJCu7S2xxNBnXtOxR/1TzO4LvVQsWJo0c5z91dD Aid3uYhx1SPwcaF5O5CfRQcp1JSLOWKZOaxO+u+DmtYIM746jrz3FOrfEN8mQp0q CwUSE/Vum7ImOsNUO308QnGmL7s/FGkp86/JtNTbAxJ47Rhqu5lcXj3q1ntrlLdX VFC+K7mNdwNtc1vqB03W5gamyD1qVcTvvwJ3D9cpQAySTDyRFF9cGw+TrzaDl48B 8iiY7D/KkhHuY4jskCF6xyjzloK9RfgKg2FzEBndoESt7bEw4eufF9wnrfV/M1xw 6U4DSjZxgqUwV7YqMX/VnpcEuxg5q9emCQmBfudnVIPKuOITg8x1oyE1e036MDo5 zon/cRIxqaSt8K6rI7TafxQIwpM541N89O/VZbcVey5JFIu1kew4G/gMivMOyroE +xqxLmeGgD10LMZOgoRsNBiKDy8JLJa2lO2dVTZMV4bdtCngeDikDNLqYUcW8lfa 5ZsQBceoCI6abj4PV35N7dHVATFudhrZmhY0epHt13xmRHUFTywOktu/TkOZM8HR eU2TBtOsDF6N5SFunvAC =s5yy -----END PGP SIGNATURE-----
VAR-201709-0812 CVE-2017-14705 DenyAll WAF and i-Suite Command injection vulnerability CVSS V2: 9.3
CVSS V3: 8.1
Severity: HIGH
DenyAll WAF before 6.4.1 allows unauthenticated remote command execution via TCP port 3001 because shell metacharacters can be inserted into the type parameter to the tailDateFile function in /webservices/stream/tail.php. An iToken authentication parameter is required but can be obtained by exploiting CVE-2017-14706. This affects DenyAll i-Suite LTS 5.5.0 through 5.5.12, i-Suite 5.6, Web Application Firewall 5.7, and Web Application Firewall 6.x before 6.4.1, with On Premises or AWS/Azure cloud deployments. DenyAll WAF and i-Suite Contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. There are security vulnerabilities in several DenyAll products. Remote attackers can exploit this vulnerability to execute commands through TCP port 3001
VAR-201709-0813 CVE-2017-14706 DenyAll WAF and i-Suite Authentication vulnerability CVSS V2: 7.5
CVSS V3: 9.8
Severity: CRITICAL
DenyAll WAF before 6.4.1 allows unauthenticated remote attackers to obtain authentication information by making a typeOf=debug request to /webservices/download/index.php, and then reading the iToken field in the reply. This affects DenyAll i-Suite LTS 5.5.0 through 5.5.12, i-Suite 5.6, Web Application Firewall 5.7, and Web Application Firewall 6.x before 6.4.1, with On Premises or AWS/Azure cloud deployments. DenyAll WAF and i-Suite Contains an authentication vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. There are security vulnerabilities in several DenyAll products
VAR-201709-1252 No CVE Shenzhen Huanghe Digital Histream Product Network Camera Has Unauthorized Access Vulnerability CVSS V2: 7.5
CVSS V3: -
Severity: HIGH
Histream network cameras provide customers with complete network video surveillance products and overall solutions. An unauthorized access vulnerability exists in the Shenzhen Huanghe Digital Histream product network camera. Attackers can use this vulnerability to directly obtain the management username and password, and log in to the device monitoring camera directly.
VAR-201709-1253 No CVE Guangzhou Southern Satellite Navigation Instrument Co., Ltd. NETS9 Multi-Star System Reference Station Receiver Control Software Has SQL Injection Vulnerability CVSS V2: 7.8
CVSS V3: -
Severity: HIGH
NETS9 is a multi-satellite reference station receiver. There is a SQL injection vulnerability in the receiver control software of the NETS9 multi-satellite reference station of Guangzhou Nanfang Satellite Navigation Instrument Co., Ltd., allowing attackers to use the vulnerability to obtain sensitive information in the database.
VAR-201709-0672 CVE-2017-3770 LXCA Command injection vulnerability CVSS V2: 6.5
CVSS V3: 8.8
Severity: HIGH
Privilege escalation vulnerability in LXCA versions earlier than 1.3.2 where an authenticated user may be able to abuse certain web interface functionality to execute privileged commands within the underlying LXCA operating system. LXCA Contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Lenovo LXCA is a set of file system management tools of China Lenovo (Lenovo). There is a privilege escalation vulnerability in versions earlier than Lenovo LXCA 1.3.2
VAR-201709-0671 CVE-2017-3763 LXCA Vulnerabilities related to certificate and password management CVSS V2: 2.1
CVSS V3: 6.7
Severity: MEDIUM
An attacker who obtains access to the location where the LXCA file system is stored may be able to access credentials of local LXCA accounts in LXCA versions earlier than 1.3.2. LXCA Contains vulnerabilities related to certificate and password management.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. Lenovo LXCA is a set of file system management tools of China Lenovo (Lenovo). A security vulnerability exists in versions prior to Lenovo LXCA 1.3.2
VAR-201709-0712 CVE-2017-14001 Digium Asterisk GUI OS Command injection vulnerability CVSS V2: 9.0
CVSS V3: 8.8
Severity: HIGH
An Improper Neutralization of Special Elements used in an OS Command issue was discovered in Digium Asterisk GUI 2.1.0 and prior. An OS command injection vulnerability has been identified that may allow the execution of arbitrary code on the system through the inclusion of OS commands in the URL request of the program. The Asterisk GUI is a framework for configuring graphical user interfaces. Digium Asterisk GUI is prone to an OS command-injection vulnerability because it fails to properly sanitize user-supplied input. Successfully exploiting this issue may allow an attacker to execute arbitrary code in the context of the affected application. Failed exploit attempts will result in a denial-of-service condition. Asterisk GUI 2.1.0 and prior versions are vulnerable
VAR-201711-0050 CVE-2017-14359 HPE Performance Center Vulnerable to cross-site scripting CVSS V2: 3.5
CVSS V3: 5.4
Severity: MEDIUM
A potential security vulnerability has been identified in HPE Performance Center versions 12.20. The vulnerability could be remotely exploited to allow cross-site scripting. HP Performance Center is prone to an unspecified cross-site scripting vulnerability because it fails to properly sanitize user-supplied input. Remote attackers can exploit this issue to execute arbitrary script code in the browser of an unsuspecting user in the context of the affected site. This may allow the attacker to steal cookie-based authentication credentials and launch other attacks
VAR-201710-0792 CVE-2017-13995 iniNet Solutions GmbH SCADA Webserver Unauthorized Access Vulnerability CVSS V2: 7.5
CVSS V3: 10.0
Severity: CRITICAL
An Improper Authentication issue was discovered in iniNet Solutions iniNet Webserver, all versions prior to V2.02.0100. The webserver does not properly authenticate users, which may allow a malicious attacker to access sensitive information such as HMI pages or modify PLC variables. iniNet Solutions SCADA Web Server Contains an authentication vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. SCADA Webserver is a third-party web-based server software. IniNet Solutions SCADA Web Server is prone to an authentication-bypass vulnerability. An attacker can exploit this issue to bypass the authentication mechanism and perform unauthorized actions. This may lead to further attacks. IniNet Solutions SCADA Web Server prior to 2.02.0100 are vulnerable
VAR-201709-0829 CVE-2017-14651 WSO2 Data Analytics Server Cross-Site Scripting Vulnerability CVSS V2: 3.5
CVSS V3: 4.8
Severity: MEDIUM
WSO2 Data Analytics Server 3.1.0 has XSS in carbon/resources/add_collection_ajaxprocessor.jsp via the collectionName or parentPath parameter. WSO2DataAnalyticsServer is a data analysis server of WSO2 Corporation of the United States, which provides real-time analysis of data streams, complex event processing and machine learning. A cross-site scripting vulnerability exists in the carbon/resources/add_collection_ajaxprocessor.jsp file in WSO2DataAnalyticsServer version 3.1.0. A remote attacker can use this vulnerability to hijack a user's session with the help of the \342\200\230collectionName\342\200\231 or \342\200\230parentPath\342\200\231 parameter, and change the login user password, causing the user session to fail
VAR-201710-0794 CVE-2017-13997 Schneider Electric InduSoft Web Studio and InTouch Machine Edition Vulnerabilities related to lack of authentication for critical functions CVSS V2: 10.0
CVSS V3: 9.8
Severity: CRITICAL
A Missing Authentication for Critical Function issue was discovered in Schneider Electric InduSoft Web Studio v8.0 SP2 or prior, and InTouch Machine Edition v8.0 SP2 or prior. InduSoft Web Studio provides the capability for an HMI client to trigger script execution on the server for the purposes of performing customized calculations or actions. A remote malicious entity could bypass the server authentication and trigger the execution of an arbitrary command. The command is executed under high privileges and could lead to a complete compromise of the server. Multiple Schneider Electric Products are prone to an authentication-bypass vulnerability. This may aid in further attacks
VAR-201710-0797 CVE-2017-14000 Ctek SkyRouter Authentication Bypass Vulnerability CVSS V2: 7.5
CVSS V3: 9.4
Severity: CRITICAL
An Improper Authentication issue was discovered in Ctek SkyRouter Series 4200 and 4400, all versions prior to V6.00.11. By accessing a specific uniform resource locator (URL) on the web server, a malicious user is able to access the application without authenticating. Ctek SkyRouter Series 4200 and 4400 Contains an authentication vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. SkyRouter is a product of the Swedish CTEK company that manages wireless IP connections. Ctek SkyRouter is prone to an authentication-bypass vulnerability. This may lead to further attacks. Versions prior to ICtek SkyRouter 6.00.11 are vulnerable
VAR-201710-1320 CVE-2017-9628 Saia Burgess Controls PCD Controllers Information Disclosure Vulnerability CVSS V2: 5.0
CVSS V3: 5.3
Severity: MEDIUM
An Information Exposure issue was discovered in Saia Burgess Controls PCD Controllers with PCD firmware versions prior to 1.28.16 or 1.24.69. In certain circumstances, the device pads Ethernet frames with memory contents. PCD is prone to an unspecified information-disclosure vulnerability. Attackers can exploit this issue to obtain sensitive information that may aid in further attacks. Versions prior to PCD 1.28.16 or 1.24.69 are vulnerable
VAR-201709-1104 CVE-2017-8012 plural EMC Access control vulnerabilities in products CVSS V2: 5.8
CVSS V3: 7.4
Severity: HIGH
In EMC ViPR SRM, Storage M&R, VNX M&R, and M&R (Watch4Net) for SAS Solution Packs, the Java Management Extensions (JMX) protocol used to communicate between components in the Alerting and/or Compliance components can be leveraged to create a denial of service (DoS) condition. Attackers with knowledge of JMX agent user credentials could potentially exploit this vulnerability to create arbitrary files on the affected system and create a DoS condition by leveraging inherent JMX protocol capabilities. This vulnerability allows remote attackers to create a denial of service on vulnerable installations of Dell EMC VNX Monitoring and Reporting. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed. The specific flaw exists within an exposed RMI registry, which listens on TCP port 52569 by default. The issue results from the lack of proper validation of user-supplied data, which can result in deserialization of untrusted data. An attacker can leverage this vulnerability to create a denial-of-service condition to users of the system. Multiple EMC products are prone to a denial-of-service vulnerability. Remote attackers may exploit this issue to cause denial-of-service conditions, denying service to legitimate users. The following EMC products are vulnerable: EMC ViPR SRM EMC Storage M&R EMC VNX M&R EMC M&R (Watch4Net) for SAS Solution Packs. Details: * Directory Traversal Vulnerability (CVE-2017-8007) Webservice Gateway used in these products is affected by a directory traversal vulnerability. Please see ESA-2017-089 for more details on how to change the credentials. * Customers are strongly advised to review product documentation and use firewall controls to limit access to WebService Gateway and all other internal ports only to those servers that require access to them. o For vApp installations, please review Knowledge Base article 503844 (https://support.emc.com/kb/503844) for guidance on making firewall changes within the vApp. Mitigation information for CVE-2017-8012 for all customers: * Change any default JMX agent credentials. Please see ESA-2017-089 for more details on how to change the credentials. * Review product documentation and use firewall controls to limit access to the JMX ports and all other internal ports only to those servers that require access to them. o For vApp installations, please review Knowledge Base article 503844 (https://support.emc.com/kb/503844) for guidance on making firewall changes within the vApp. * Future releases will contain further measures to remove or harden communication via the JMX protocol. EMC VNX M&R customers must migrate to EMC Storage M&R version 4.1 or later to receive future security fixes. Link to remedies: * For EMC ViPR SRM and EMC Storage M&R, registered EMC Online Support customers can download patches and software from support.emc.com at: https://support.emc.com/downloads/34247_ViPR-SRM. * For EMC M&R (Watch4Net) for SAS Solution Packs, registered EMC Online Support customers can download patches and software from support.emc.com at: https://support.emc.com/downloads/6175_Smarts-Service-Assurance-Manager * For VNX M&R, registered EMC Online Support customers can follow the mitigation steps described above. Credits: EMC would like to thank rgod working with Trend Micro's Zero Day Initiative for reporting these vulnerabilities. -----BEGIN PGP SIGNATURE----- Version: GnuPG v2 iQEcBAEBCAAGBQJZwl9WAAoJEHbcu+fsE81ZLegH+wU8RTmKZt33ThZsOJcGekEJ CuD+v/JawNGDxK6nheFPreMa/IQRTTskGeVmbqypcV6Gh5pfx711OYzMnXBsufqH LNNywQ6q1hsM5LPYkZ1hu9bHcotM5Uvd80Lpsld1xU3TGbU+ruULPK2WY1QHcIyL IvU43HW803SCTS5lNaL+OKX3Coa+UUW1t7psJ0mVdCC3U19Qh+RrZPSnyHBThe5Z Btho0WoKauY+jqO6RxML+BT8D02Dn/+kjnlWyaca0QTXu8k0oEBqLI+vnO+KJCKY HxkxI1uvWsWy+z7x3MdsatFCl9ksMpXsWBoPR4EgZGbebDX38R9+ww/ryWQDPQ8= =jk2j -----END PGP SIGNATURE-----
VAR-201709-0842 CVE-2017-14616 WatchGuard Fireware Vulnerable to resource exhaustion CVSS V2: 7.8
CVSS V3: 7.5
Severity: HIGH
An FBX-5312 issue was discovered in WatchGuard Fireware before 12.0. If a login attempt is made in the XML-RPC interface with an XML message containing an empty member element, the wgagent crashes, logging out any user with a session opened in the UI. By continuously executing the failed login attempts, UI management of the device becomes impossible. WatchGuard Fireware Contains a resource exhaustion vulnerability.Service operation interruption (DoS) There is a possibility of being put into a state. WatchGuardFirewareXTM is a firewall device from WatchGuard, Inc., which provides intrusion prevention, spam virus filtering, and SSLVPN through intelligent layering technology. WatchGuardFireware is the firmware in it. A security vulnerability exists in versions of WatchGuardFireware prior to 12.0. An attacker could exploit the vulnerability with a continuous invalid login request to cause a denial of service (wgagent crash)
VAR-201709-1103 CVE-2017-8007 plural EMC Product vulnerable to path traversal CVSS V2: 6.5
CVSS V3: 8.8
Severity: HIGH
In EMC ViPR SRM, Storage M&R, VNX M&R, and M&R (Watch4Net) for SAS Solution Packs, the Webservice Gateway is affected by a directory traversal vulnerability. Attackers with knowledge of Webservice Gateway credentials could potentially exploit this vulnerability to access unauthorized information, and modify or delete data, by supplying specially crafted strings in input parameters of the web service call. This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of Dell EMC VNX Monitoring and Reporting. Although authentication is required to exploit this vulnerability, the existing authentication mechanism can be bypassed.The specific flaw exists within Scheduler.class. The issue results from the lack of proper validation of a user-supplied path prior to using it in file operations. An attacker can leverage this vulnerability to execute arbitrary code under the context of SYSTEM. EMCViPRSRM and other products are products of American company. EMCViPRSRM is a set of storage resource management software. StorageM&R is a data storage collector. WebserviceGateway is one of the gateways. A remote attacker could use the vulnerability to access information, change or delete data by sending a request with a directory traversal sequence of \342\200\230../\342\200\231. Remote attackers can use specially crafted requests with directory-traversal sequences ('../') to read arbitrary files in the context of the application. This may aid in further attacks. -----BEGIN PGP SIGNED MESSAGE----- Hash: SHA256 ESA-2017-081: EMC ViPR SRM, EMC Storage M&R, EMC VNX M&R, EMC M&R (Watch4Net) for SAS Solution Packs Multiple Vulnerabilities EMC Identifier: ESA-2017-081 CVE Identifier: CVE-2017-8007, CVE-2017-8012 Severity Rating: CVSS Base Score: See below for individual scores. CVSSv3 Base Score: 8.8 (AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H) * JMX Denial of Service Vulnerability (CVE-2017-8012) The Java Management Extensions (JMX) protocol used to communicate between components in the Alerting and/or Compliance components in these products can be leveraged to create a denial of service (DoS) condition. Please see ESA-2017-089 for more details on how to change the credentials. * Customers are strongly advised to review product documentation and use firewall controls to limit access to WebService Gateway and all other internal ports only to those servers that require access to them. o For vApp installations, please review Knowledge Base article 503844 (https://support.emc.com/kb/503844) for guidance on making firewall changes within the vApp. Mitigation information for CVE-2017-8012 for all customers: * Change any default JMX agent credentials. Please see ESA-2017-089 for more details on how to change the credentials. * Review product documentation and use firewall controls to limit access to the JMX ports and all other internal ports only to those servers that require access to them. o For vApp installations, please review Knowledge Base article 503844 (https://support.emc.com/kb/503844) for guidance on making firewall changes within the vApp. * Future releases will contain further measures to remove or harden communication via the JMX protocol. EMC VNX M&R customers must migrate to EMC Storage M&R version 4.1 or later to receive future security fixes. Link to remedies: * For EMC ViPR SRM and EMC Storage M&R, registered EMC Online Support customers can download patches and software from support.emc.com at: https://support.emc.com/downloads/34247_ViPR-SRM. * For EMC M&R (Watch4Net) for SAS Solution Packs, registered EMC Online Support customers can download patches and software from support.emc.com at: https://support.emc.com/downloads/6175_Smarts-Service-Assurance-Manager * For VNX M&R, registered EMC Online Support customers can follow the mitigation steps described above. Credits: EMC would like to thank rgod working with Trend Micro's Zero Day Initiative for reporting these vulnerabilities. -----BEGIN PGP SIGNATURE----- Version: GnuPG v2 iQEcBAEBCAAGBQJZwl9WAAoJEHbcu+fsE81ZLegH+wU8RTmKZt33ThZsOJcGekEJ CuD+v/JawNGDxK6nheFPreMa/IQRTTskGeVmbqypcV6Gh5pfx711OYzMnXBsufqH LNNywQ6q1hsM5LPYkZ1hu9bHcotM5Uvd80Lpsld1xU3TGbU+ruULPK2WY1QHcIyL IvU43HW803SCTS5lNaL+OKX3Coa+UUW1t7psJ0mVdCC3U19Qh+RrZPSnyHBThe5Z Btho0WoKauY+jqO6RxML+BT8D02Dn/+kjnlWyaca0QTXu8k0oEBqLI+vnO+KJCKY HxkxI1uvWsWy+z7x3MdsatFCl9ksMpXsWBoPR4EgZGbebDX38R9+ww/ryWQDPQ8= =jk2j -----END PGP SIGNATURE-----
VAR-201709-0678 CVE-2017-12215 Cisco Email Security Appliance for AsyncOS Software input validation vulnerability CVSS V2: 7.8
CVSS V3: 7.1
Severity: HIGH
A vulnerability in the email message filtering feature of Cisco AsyncOS Software for the Cisco Email Security Appliance could allow an unauthenticated, remote attacker to cause an affected device to run out of memory and stop scanning and forwarding email messages. When system memory is depleted, it can cause the filtering process to crash, resulting in a denial of service (DoS) condition on the device. This vulnerability affects software version 9.0 through the first fixed release of Cisco AsyncOS Software for Cisco Email Security Appliances, both virtual and hardware appliances, if the software is configured to apply a message filter or content filter to incoming email attachments. The vulnerability is not limited to any specific rules or actions for a message filter or content filter. Cisco Bug IDs: CSCvd29354. Vendors have confirmed this vulnerability Bug ID CSCvd29354 It is released as.Service operation interruption (DoS) There is a possibility of being put into a state. AsyncOS Software is the operating system used in it. The following releases are affected: Cisco AsyncOS Software Release 9.0, Release 9.1, Release 9.6, Release 9.7, Release 9.8, Release 10.0
VAR-201709-0659 CVE-2017-12252 Cisco FindIT Network Discovery Utility Vulnerabilities related to untrusted search paths CVSS V2: 4.6
CVSS V3: 7.8
Severity: HIGH
A vulnerability in the Cisco FindIT Network Discovery Utility could allow an authenticated, local attacker to perform a DLL preloading attack, potentially causing a partial impact to device availability, confidentiality, and integrity. The vulnerability is due to the application loading a malicious copy of a specific, nondefined DLL file instead of the DLL file it was expecting. An attacker could exploit this vulnerability by placing an affected DLL within the search path of the host system. An exploit could allow the attacker to load a malicious DLL file into the system, thus partially compromising confidentiality, integrity, and availability on the device. Cisco Bug IDs: CSCve89785. Cisco FindIT Network Discovery Utility Contains an unreliable search path vulnerability. Vendors have confirmed this vulnerability Bug ID CSCve89785 It is released as.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. CiscoFindITNetworkDiscoveryUtility is a network device manager from Cisco. This product provides management capabilities for Cisco network devices. A security vulnerability exists in CiscoFindITNetworkDiscoveryUtility. A remote attacker can leverage this issue to execute arbitrary code in the context of the affected application. Failed exploit attempts will result in a denial of service condition
VAR-201709-0611 CVE-2017-14602 Citrix NetScaler Application Delivery Controller and NetScaler Gateway Vulnerabilities related to authorization, permissions, and access control CVSS V2: 9.0
CVSS V3: 7.2
Severity: HIGH
A vulnerability has been identified in the management interface of Citrix NetScaler Application Delivery Controller (ADC) and NetScaler Gateway 10.1 before build 135.18, 10.5 before build 66.9, 10.5e before build 60.7010.e, 11.0 before build 70.16, 11.1 before build 55.13, and 12.0 before build 53.13 (except for build 41.24) that, if exploited, could allow an attacker with access to the NetScaler management interface to gain administrative access to the appliance. Citrix NetScaler ADC and NetScaler Gateway are prone to an authentication-bypass vulnerability. An attacker can exploit this issue to bypass the authentication mechanism. This may aid in further attacks. The following products are affected: Citrix NetScaler ADC and NetScaler Gateway version 12.0 prior to build 53.13 Citrix NetScaler ADC and NetScaler Gateway version 11.1 prior to build 55.13 Citrix NetScaler ADC and NetScaler Gateway version 11.0 prior to build 70.16 Citrix NetScaler ADC and NetScaler Gateway version 10.5 prior to build 66.9 Citrix NetScaler ADC and NetScaler Gateway version 10.5e prior to build 60.7010.e Citrix NetScaler ADC and NetScaler Gateway version 10.1 prior to build 135.18. The following products and versions are affected: Citrix NetScaler Gateway Release 12.0, Release 11.1, Release 11.0, Release 10.5e, Release 10.5, Release 10.1; NetScaler ADC Release 12.0, Release 11.1, Release 11.0, Release 10.5e, Release 10.5, Release 10.1