ID

VAR-202510-0511


CVE

CVE-2025-61044


TITLE

TOTOLINK X18 setEasyMeshAgentCfg function command injection vulnerability

Trust: 0.6

sources: CNVD: CNVD-2025-23585

DESCRIPTION

TOTOLINK X18 V9.1.0cu.2053_B20230309 was discovered to contain a command injection vulnerability via the agentName parameter in the setEasyMeshAgentCfg function. The TOTOLINK X18 is a mesh WiFi 6 router system launched by Taiwan's TOTOLINK. It supports WiFi 6 technology and optimizes home network coverage through its mesh functionality. An attacker could exploit this vulnerability to execute arbitrary commands

Trust: 1.44

sources: NVD: CVE-2025-61044 // CNVD: CNVD-2025-23585

IOT TAXONOMY

category:['Network device']sub_category: -

Trust: 0.6

sources: CNVD: CNVD-2025-23585

AFFECTED PRODUCTS

vendor:totolinkmodel:x18scope:eqversion:9.1.0cu.2053_b20230309

Trust: 1.0

vendor:totolinkmodel:v9.1.0cu.2053 b20230309scope:eqversion:x18

Trust: 0.6

sources: CNVD: CNVD-2025-23585 // NVD: CVE-2025-61044

CVSS

SEVERITY

CVSSV2

CVSSV3

nvd@nist.gov: CVE-2025-61044
value: CRITICAL

Trust: 1.0

134c704f-9b21-4f2e-91b3-4a467353bcc0: CVE-2025-61044
value: MEDIUM

Trust: 1.0

CNVD: CNVD-2025-23585
value: HIGH

Trust: 0.6

CNVD: CNVD-2025-23585
severity: HIGH
baseScore: 10.0
vectorString: AV:N/AC:L/AU:N/C:C/I:C/A:C
accessVector: NETWORK
accessComplexity: LOW
authentication: NONE
confidentialityImpact: COMPLETE
integrityImpact: COMPLETE
availabilityImpact: COMPLETE
exploitabilityScore: 10.0
impactScore: 10.0
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.6

nvd@nist.gov: CVE-2025-61044
baseSeverity: CRITICAL
baseScore: 9.8
vectorString: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
attackVector: NETWORK
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 3.9
impactScore: 5.9
version: 3.1

Trust: 1.0

134c704f-9b21-4f2e-91b3-4a467353bcc0: CVE-2025-61044
baseSeverity: MEDIUM
baseScore: 6.5
vectorString: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:N
attackVector: NETWORK
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: LOW
integrityImpact: LOW
availabilityImpact: NONE
exploitabilityScore: 3.9
impactScore: 2.5
version: 3.1

Trust: 1.0

sources: CNVD: CNVD-2025-23585 // NVD: CVE-2025-61044 // NVD: CVE-2025-61044

PROBLEMTYPE DATA

problemtype:CWE-77

Trust: 1.0

sources: NVD: CVE-2025-61044

EXTERNAL IDS

db:NVDid:CVE-2025-61044

Trust: 1.6

db:CNVDid:CNVD-2025-23585

Trust: 0.6

sources: CNVD: CNVD-2025-23585 // NVD: CVE-2025-61044

REFERENCES

url:https://github.com/ilovekeer/iot/blob/main/totolink/x18/seteasymeshagentcfg/2.md

Trust: 1.6

sources: CNVD: CNVD-2025-23585 // NVD: CVE-2025-61044

SOURCES

db:CNVDid:CNVD-2025-23585
db:NVDid:CVE-2025-61044

LAST UPDATE DATE

2025-10-17T23:27:50.289000+00:00


SOURCES UPDATE DATE

db:CNVDid:CNVD-2025-23585date:2025-10-14T00:00:00
db:NVDid:CVE-2025-61044date:2025-10-16T20:15:34.650

SOURCES RELEASE DATE

db:CNVDid:CNVD-2025-23585date:2025-10-14T00:00:00
db:NVDid:CVE-2025-61044date:2025-10-01T15:15:49.013