ID

VAR-202508-2133


CVE

CVE-2025-55499


TITLE

Shenzhen Tenda Technology Co.,Ltd.  of  AC6  Classic buffer overflow vulnerability in firmware

Trust: 0.8

sources: JVNDB: JVNDB-2025-012141

DESCRIPTION

Tenda AC6 V15.03.06.23_multi was discovered to contain a buffer overflow via the ntpServer parameter in the fromSetSysTime function. Shenzhen Tenda Technology Co.,Ltd. It supports both IPv4 and IPv6 protocols, utilizes the 802.11ac/n wireless standard, and offers a wireless transmission rate of 1167 Mbps. Detailed vulnerability details are currently unavailable

Trust: 2.16

sources: NVD: CVE-2025-55499 // JVNDB: JVNDB-2025-012141 // CNVD: CNVD-2025-20148

IOT TAXONOMY

category:['Network device']sub_category: -

Trust: 0.6

sources: CNVD: CNVD-2025-20148

AFFECTED PRODUCTS

vendor:tendamodel:ac6scope:eqversion:15.03.06.23

Trust: 1.0

vendor:tendamodel:ac6scope:eqversion: -

Trust: 0.8

vendor:tendamodel:ac6scope: - version: -

Trust: 0.8

vendor:tendamodel:ac6scope:eqversion:ac6 firmware 15.03.06.23

Trust: 0.8

vendor:tendamodel:ac6 v15.03.06.23 multiscope: - version: -

Trust: 0.6

sources: CNVD: CNVD-2025-20148 // JVNDB: JVNDB-2025-012141 // NVD: CVE-2025-55499

CVSS

SEVERITY

CVSSV2

CVSSV3

134c704f-9b21-4f2e-91b3-4a467353bcc0: CVE-2025-55499
value: MEDIUM

Trust: 1.0

OTHER: JVNDB-2025-012141
value: MEDIUM

Trust: 0.8

CNVD: CNVD-2025-20148
value: MEDIUM

Trust: 0.6

CNVD: CNVD-2025-20148
severity: MEDIUM
baseScore: 6.1
vectorString: AV:N/AC:H/AU:N/C:C/I:P/A:N
accessVector: NETWORK
accessComplexity: HIGH
authentication: NONE
confidentialityImpact: COMPLETE
integrityImpact: PARTIAL
availabilityImpact: NONE
exploitabilityScore: 4.9
impactScore: 7.8
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.6

134c704f-9b21-4f2e-91b3-4a467353bcc0: CVE-2025-55499
baseSeverity: MEDIUM
baseScore: 6.5
vectorString: CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:L/A:N
attackVector: NETWORK
attackComplexity: HIGH
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: LOW
availabilityImpact: NONE
exploitabilityScore: 2.2
impactScore: 4.2
version: 3.1

Trust: 1.0

OTHER: JVNDB-2025-012141
baseSeverity: MEDIUM
baseScore: 6.5
vectorString: CVSS:3.0/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:L/A:N
attackVector: NETWORK
attackComplexity: HIGH
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: LOW
availabilityImpact: NONE
exploitabilityScore: NONE
impactScore: NONE
version: 3.0

Trust: 0.8

sources: CNVD: CNVD-2025-20148 // JVNDB: JVNDB-2025-012141 // NVD: CVE-2025-55499

PROBLEMTYPE DATA

problemtype:CWE-120

Trust: 1.0

problemtype:Classic buffer overflow (CWE-120) [ others ]

Trust: 0.8

sources: JVNDB: JVNDB-2025-012141 // NVD: CVE-2025-55499

EXTERNAL IDS

db:NVDid:CVE-2025-55499

Trust: 3.2

db:JVNDBid:JVNDB-2025-012141

Trust: 0.8

db:CNVDid:CNVD-2025-20148

Trust: 0.6

sources: CNVD: CNVD-2025-20148 // JVNDB: JVNDB-2025-012141 // NVD: CVE-2025-55499

REFERENCES

url:https://github.com/solitarygrass/iot_vuln/blob/main/tenda/ac6/ac6v2.0rtl_v15.03.06.23/fromsetsystime/poc.md

Trust: 2.4

url:https://nvd.nist.gov/vuln/detail/cve-2025-55499

Trust: 0.8

sources: CNVD: CNVD-2025-20148 // JVNDB: JVNDB-2025-012141 // NVD: CVE-2025-55499

SOURCES

db:CNVDid:CNVD-2025-20148
db:JVNDBid:JVNDB-2025-012141
db:NVDid:CVE-2025-55499

LAST UPDATE DATE

2025-09-06T00:12:57.204000+00:00


SOURCES UPDATE DATE

db:CNVDid:CNVD-2025-20148date:2025-09-03T00:00:00
db:JVNDBid:JVNDB-2025-012141date:2025-08-22T08:00:00
db:NVDid:CVE-2025-55499date:2025-08-21T18:22:20.913

SOURCES RELEASE DATE

db:CNVDid:CNVD-2025-20148date:2025-09-02T00:00:00
db:JVNDBid:JVNDB-2025-012141date:2025-08-22T00:00:00
db:NVDid:CVE-2025-55499date:2025-08-20T14:15:47.313