ID

VAR-202508-0172


CVE

CVE-2025-8646


TITLE

JVCKENWOOD Corporation  of  DMX958XR  in the firmware  OS  Command injection vulnerability

Trust: 0.8

sources: JVNDB: JVNDB-2025-011100

DESCRIPTION

Kenwood DMX958XR Firmware Update Command Injection Vulnerability. This vulnerability allows physically present attackers to execute arbitrary code on affected installations of Kenwood DMX958XR devices. Authentication is not required to exploit this vulnerability. The specific flaw exists within the firmware update process. The issue results from the lack of proper validation of a user-supplied string before using it to execute a system call. An attacker can leverage this vulnerability to execute code in the context of root. Was ZDI-CAN-26269. JVCKENWOOD Corporation of DMX958XR The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. The Kenwood DMX958XR is an in-vehicle infotainment system from Kenwood

Trust: 2.79

sources: NVD: CVE-2025-8646 // JVNDB: JVNDB-2025-011100 // ZDI: ZDI-25-794 // CNVD: CNVD-2025-20301

IOT TAXONOMY

category:['IoT']sub_category: -

Trust: 0.6

sources: CNVD: CNVD-2025-20301

AFFECTED PRODUCTS

vendor:jvckenwoodmodel:dmx958xrscope:eqversion:1.0.0005.4600

Trust: 1.0

vendor:jvckenwoodmodel:dmx958xrscope: - version: -

Trust: 0.8

vendor:jvckenwoodmodel:dmx958xrscope:eqversion: -

Trust: 0.8

vendor:jvckenwoodmodel:dmx958xrscope:eqversion:dmx958xr firmware 1.0.0005.4600

Trust: 0.8

vendor:kenwoodmodel:dmx958xrscope: - version: -

Trust: 0.7

vendor:kenwoodmodel:dmx958xrscope:eqversion:1.0.0005.4600

Trust: 0.6

sources: ZDI: ZDI-25-794 // CNVD: CNVD-2025-20301 // JVNDB: JVNDB-2025-011100 // NVD: CVE-2025-8646

CVSS

SEVERITY

CVSSV2

CVSSV3

zdi-disclosures@trendmicro.com: CVE-2025-8646
value: MEDIUM

Trust: 1.0

OTHER: JVNDB-2025-011100
value: MEDIUM

Trust: 0.8

ZDI: CVE-2025-8646
value: MEDIUM

Trust: 0.7

CNVD: CNVD-2025-20301
value: HIGH

Trust: 0.6

CNVD: CNVD-2025-20301
severity: HIGH
baseScore: 7.2
vectorString: AV:L/AC:L/AU:N/C:C/I:C/A:C
accessVector: LOCAL
accessComplexity: LOW
authentication: NONE
confidentialityImpact: COMPLETE
integrityImpact: COMPLETE
availabilityImpact: COMPLETE
exploitabilityScore: 3.9
impactScore: 10.0
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.6

zdi-disclosures@trendmicro.com: CVE-2025-8646
baseSeverity: MEDIUM
baseScore: 6.8
vectorString: CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
attackVector: PHYSICAL
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 0.9
impactScore: 5.9
version: 3.0

Trust: 1.0

OTHER: JVNDB-2025-011100
baseSeverity: MEDIUM
baseScore: 6.8
vectorString: CVSS:3.0/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
attackVector: PHYSICAL
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: NONE
impactScore: NONE
version: 3.0

Trust: 0.8

ZDI: CVE-2025-8646
baseSeverity: MEDIUM
baseScore: 6.8
vectorString: AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
attackVector: PHYSICAL
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 0.9
impactScore: 5.9
version: 3.0

Trust: 0.7

sources: ZDI: ZDI-25-794 // CNVD: CNVD-2025-20301 // JVNDB: JVNDB-2025-011100 // NVD: CVE-2025-8646

PROBLEMTYPE DATA

problemtype:CWE-78

Trust: 1.0

problemtype:OS Command injection (CWE-78) [ others ]

Trust: 0.8

sources: JVNDB: JVNDB-2025-011100 // NVD: CVE-2025-8646

EXTERNAL IDS

db:NVDid:CVE-2025-8646

Trust: 3.9

db:ZDIid:ZDI-25-794

Trust: 3.1

db:JVNDBid:JVNDB-2025-011100

Trust: 0.8

db:ZDI_CANid:ZDI-CAN-26269

Trust: 0.7

db:CNVDid:CNVD-2025-20301

Trust: 0.6

sources: ZDI: ZDI-25-794 // CNVD: CNVD-2025-20301 // JVNDB: JVNDB-2025-011100 // NVD: CVE-2025-8646

REFERENCES

url:https://www.zerodayinitiative.com/advisories/zdi-25-794/

Trust: 2.4

url:https://nvd.nist.gov/vuln/detail/cve-2025-8646

Trust: 0.8

sources: CNVD: CNVD-2025-20301 // JVNDB: JVNDB-2025-011100 // NVD: CVE-2025-8646

CREDITS

@ByteInsight

Trust: 0.7

sources: ZDI: ZDI-25-794

SOURCES

db:ZDIid:ZDI-25-794
db:CNVDid:CNVD-2025-20301
db:JVNDBid:JVNDB-2025-011100
db:NVDid:CVE-2025-8646

LAST UPDATE DATE

2025-09-08T23:07:39.297000+00:00


SOURCES UPDATE DATE

db:ZDIid:ZDI-25-794date:2025-08-05T00:00:00
db:CNVDid:CNVD-2025-20301date:2025-09-04T00:00:00
db:JVNDBid:JVNDB-2025-011100date:2025-08-08T09:04:00
db:NVDid:CVE-2025-8646date:2025-08-07T16:51:31.050

SOURCES RELEASE DATE

db:ZDIid:ZDI-25-794date:2025-08-05T00:00:00
db:CNVDid:CNVD-2025-20301date:2025-09-05T00:00:00
db:JVNDBid:JVNDB-2025-011100date:2025-08-08T00:00:00
db:NVDid:CVE-2025-8646date:2025-08-06T02:15:53.073