ID

VAR-202507-2844


CVE

CVE-2025-51087


TITLE

Tenda AC8V4 Buffer Overflow Vulnerability (CNVD-2025-17346)

Trust: 0.6

sources: CNVD: CNVD-2025-17346

DESCRIPTION

Tenda AC8V4 V16.03.34.06` was discovered to contain stack overflow at /goform/saveParentControlInfo. The manipulation of the argument time leads to stack-based buffer overflow. The Tenda AC8V4 is a wireless router manufactured by the Chinese company Tenda. Detailed vulnerability details are not currently available

Trust: 1.44

sources: NVD: CVE-2025-51087 // CNVD: CNVD-2025-17346

IOT TAXONOMY

category:['Network device']sub_category: -

Trust: 0.6

sources: CNVD: CNVD-2025-17346

AFFECTED PRODUCTS

vendor:tendamodel:ac8scope:eqversion:16.03.34.06

Trust: 1.0

vendor:tendamodel:ac8v4scope:eqversion:v16.03.34.06

Trust: 0.6

sources: CNVD: CNVD-2025-17346 // NVD: CVE-2025-51087

CVSS

SEVERITY

CVSSV2

CVSSV3

134c704f-9b21-4f2e-91b3-4a467353bcc0: CVE-2025-51087
value: HIGH

Trust: 1.0

CNVD: CNVD-2025-17346
value: HIGH

Trust: 0.6

CNVD: CNVD-2025-17346
severity: HIGH
baseScore: 9.0
vectorString: AV:N/AC:L/AU:N/C:C/I:P/A:P
accessVector: NETWORK
accessComplexity: LOW
authentication: NONE
confidentialityImpact: COMPLETE
integrityImpact: PARTIAL
availabilityImpact: PARTIAL
exploitabilityScore: 10.0
impactScore: 8.5
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.6

134c704f-9b21-4f2e-91b3-4a467353bcc0: CVE-2025-51087
baseSeverity: HIGH
baseScore: 8.6
vectorString: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:L/A:L
attackVector: NETWORK
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: LOW
availabilityImpact: LOW
exploitabilityScore: 3.9
impactScore: 4.7
version: 3.1

Trust: 1.0

sources: CNVD: CNVD-2025-17346 // NVD: CVE-2025-51087

PROBLEMTYPE DATA

problemtype:CWE-121

Trust: 1.0

sources: NVD: CVE-2025-51087

PATCH

title:Patch for Tenda AC8V4 Buffer Overflow Vulnerability (CNVD-2025-17346)url:https://www.cnvd.org.cn/patchInfo/show/714476

Trust: 0.6

sources: CNVD: CNVD-2025-17346

EXTERNAL IDS

db:NVDid:CVE-2025-51087

Trust: 1.6

db:CNVDid:CNVD-2025-17346

Trust: 0.6

sources: CNVD: CNVD-2025-17346 // NVD: CVE-2025-51087

REFERENCES

url:https://github.com/tl-sn/iot/blob/main/tenda/tenda-ac8v4%20%20v16.03.34.06/cve-2025-51087.md

Trust: 1.6

url:http://tenda.com

Trust: 1.0

sources: CNVD: CNVD-2025-17346 // NVD: CVE-2025-51087

SOURCES

db:CNVDid:CNVD-2025-17346
db:NVDid:CVE-2025-51087

LAST UPDATE DATE

2025-08-02T23:14:06.429000+00:00


SOURCES UPDATE DATE

db:CNVDid:CNVD-2025-17346date:2025-08-01T00:00:00
db:NVDid:CVE-2025-51087date:2025-07-28T17:02:56.940

SOURCES RELEASE DATE

db:CNVDid:CNVD-2025-17346date:2025-07-31T00:00:00
db:NVDid:CVE-2025-51087date:2025-07-24T15:15:26.693