ID

VAR-202506-0628


CVE

CVE-2025-5824


TITLE

plural  autel  Same Origin Policy Violation Vulnerability in Products

Trust: 0.8

sources: JVNDB: JVNDB-2025-013673

DESCRIPTION

Autel MaxiCharger AC Wallbox Commercial Origin Validation Error Authentication Bypass Vulnerability. This vulnerability allows network-adjacent attackers to bypass authentication on affected installations of Autel MaxiCharger AC Wallbox Commercial. An attacker must first obtain the ability to pair a malicious Bluetooth device with the target system in order to exploit this vulnerability. The specific flaw exists within the handling of bluetooth pairing requests. The issue results from insufficient validation of the origin of commands. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-26353. maxicharger ac elite business c50 firmware, MaxiCharger AC Pro firmware, MaxiCharger AC Ultra firmware etc. autel The product contains a same-origin policy violation vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. Autel MaxiCharger AC Wallbox Commercial is a smart AI electric vehicle charger from Autel, a US company

Trust: 2.79

sources: NVD: CVE-2025-5824 // JVNDB: JVNDB-2025-013673 // ZDI: ZDI-25-343 // CNVD: CNVD-2025-14951

IOT TAXONOMY

category:['IoT']sub_category: -

Trust: 0.6

sources: CNVD: CNVD-2025-14951

AFFECTED PRODUCTS

vendor:autelmodel:maxicharger ac ultrascope:ltversion:1.56.51

Trust: 1.0

vendor:autelmodel:maxicharger dc compact pedestalscope:ltversion:1.56.51

Trust: 1.0

vendor:autelmodel:maxicharger dc fastscope:ltversion:1.56.51

Trust: 1.0

vendor:autelmodel:maxicharger dc compact mobilescope:ltversion:1.39.51

Trust: 1.0

vendor:autelmodel:maxicharger dh480scope:ltversion:1.56.51

Trust: 1.0

vendor:autelmodel:maxicharger dc hipowerscope:ltversion:1.39.51

Trust: 1.0

vendor:autelmodel:maxicharger single chargerscope:ltversion:1.39.51

Trust: 1.0

vendor:autelmodel:maxicharger ac proscope:ltversion:1.39.51

Trust: 1.0

vendor:autelmodel:maxicharger ac elite business c50scope:ltversion:1.56.51

Trust: 1.0

vendor:autelmodel:maxicharger dc compact pedestalscope:ltversion:1.39.51

Trust: 1.0

vendor:autelmodel:maxicharger single chargerscope:ltversion:1.56.51

Trust: 1.0

vendor:autelmodel:maxicharger ac ultrascope:ltversion:1.39.51

Trust: 1.0

vendor:autelmodel:maxicharger dc fastscope:ltversion:1.39.51

Trust: 1.0

vendor:autelmodel:maxicharger dc hipowerscope:ltversion:1.56.51

Trust: 1.0

vendor:autelmodel:maxicharger dh480scope:ltversion:1.39.51

Trust: 1.0

vendor:autelmodel:maxicharger ac proscope:ltversion:1.56.51

Trust: 1.0

vendor:autelmodel:maxicharger dc compact mobilescope:ltversion:1.56.51

Trust: 1.0

vendor:autelmodel:maxicharger ac elite business c50scope:ltversion:1.39.51

Trust: 1.0

vendor:autelmodel:maxicharger dc hipowerscope: - version: -

Trust: 0.8

vendor:autelmodel:maxicharger ac proscope: - version: -

Trust: 0.8

vendor:autelmodel:maxicharger dh480scope: - version: -

Trust: 0.8

vendor:autelmodel:maxicharger single chargerscope: - version: -

Trust: 0.8

vendor:autelmodel:maxicharger dc compact mobilescope: - version: -

Trust: 0.8

vendor:autelmodel:maxicharger ac ultrascope: - version: -

Trust: 0.8

vendor:autelmodel:maxicharger ac elite business c50scope: - version: -

Trust: 0.8

vendor:autelmodel:maxicharger dc fastscope: - version: -

Trust: 0.8

vendor:autelmodel:maxicharger dc compact pedestalscope: - version: -

Trust: 0.8

vendor:autelmodel:maxicharger ac wallbox commercialscope: - version: -

Trust: 0.7

vendor:autelmodel:maxicharger ac wallbox commercial <v1.39.51scope: - version: -

Trust: 0.6

vendor:autelmodel:maxicharger ac wallbox commercial <v1.56.51scope: - version: -

Trust: 0.6

sources: ZDI: ZDI-25-343 // CNVD: CNVD-2025-14951 // JVNDB: JVNDB-2025-013673 // NVD: CVE-2025-5824

CVSS

SEVERITY

CVSSV2

CVSSV3

zdi-disclosures@trendmicro.com: CVE-2025-5824
value: MEDIUM

Trust: 1.0

nvd@nist.gov: CVE-2025-5824
value: HIGH

Trust: 1.0

NVD: CVE-2025-5824
value: HIGH

Trust: 0.8

ZDI: CVE-2025-5824
value: MEDIUM

Trust: 0.7

CNVD: CNVD-2025-14951
value: MEDIUM

Trust: 0.6

CNVD: CNVD-2025-14951
severity: MEDIUM
baseScore: 4.3
vectorString: AV:A/AC:H/AU:N/C:P/I:P/A:P
accessVector: ADJACENT_NETWORK
accessComplexity: HIGH
authentication: NONE
confidentialityImpact: PARTIAL
integrityImpact: PARTIAL
availabilityImpact: PARTIAL
exploitabilityScore: 3.2
impactScore: 6.4
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.6

zdi-disclosures@trendmicro.com: CVE-2025-5824
baseSeverity: MEDIUM
baseScore: 5.0
vectorString: CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L
attackVector: ADJACENT
attackComplexity: HIGH
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: LOW
integrityImpact: LOW
availabilityImpact: LOW
exploitabilityScore: 1.6
impactScore: 3.4
version: 3.0

Trust: 1.0

nvd@nist.gov: CVE-2025-5824
baseSeverity: HIGH
baseScore: 7.5
vectorString: CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
attackVector: ADJACENT
attackComplexity: HIGH
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 1.6
impactScore: 5.9
version: 3.1

Trust: 1.0

NVD: CVE-2025-5824
baseSeverity: HIGH
baseScore: 7.5
vectorString: CVSS:3.0/AV:A/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H
attackVector: ADJACENT NETWORK
attackComplexity: HIGH
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: NONE
impactScore: NONE
version: 3.0

Trust: 0.8

ZDI: CVE-2025-5824
baseSeverity: MEDIUM
baseScore: 5.0
vectorString: AV:A/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L
attackVector: ADJACENT
attackComplexity: HIGH
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: LOW
integrityImpact: LOW
availabilityImpact: LOW
exploitabilityScore: 1.6
impactScore: 3.4
version: 3.0

Trust: 0.7

sources: ZDI: ZDI-25-343 // CNVD: CNVD-2025-14951 // JVNDB: JVNDB-2025-013673 // NVD: CVE-2025-5824 // NVD: CVE-2025-5824

PROBLEMTYPE DATA

problemtype:CWE-346

Trust: 1.0

problemtype:Same-origin policy violation (CWE-346) [ others ]

Trust: 0.8

sources: JVNDB: JVNDB-2025-013673 // NVD: CVE-2025-5824

PATCH

title:Patch for Autel MaxiCharger AC Wallbox Commercial Authentication Bypass Vulnerabilityurl:https://www.cnvd.org.cn/patchInfo/show/704551

Trust: 0.6

sources: CNVD: CNVD-2025-14951

EXTERNAL IDS

db:NVDid:CVE-2025-5824

Trust: 3.9

db:ZDIid:ZDI-25-343

Trust: 3.1

db:JVNDBid:JVNDB-2025-013673

Trust: 0.8

db:ZDI_CANid:ZDI-CAN-26353

Trust: 0.7

db:CNVDid:CNVD-2025-14951

Trust: 0.6

sources: ZDI: ZDI-25-343 // CNVD: CNVD-2025-14951 // JVNDB: JVNDB-2025-013673 // NVD: CVE-2025-5824

REFERENCES

url:https://www.zerodayinitiative.com/advisories/zdi-25-343/

Trust: 2.4

url:https://nvd.nist.gov/vuln/detail/cve-2025-5824

Trust: 0.8

sources: CNVD: CNVD-2025-14951 // JVNDB: JVNDB-2025-013673 // NVD: CVE-2025-5824

CREDITS

Sina Kheirkhah (@SinSinology) of Summoning Team (@SummoningTeam)

Trust: 0.7

sources: ZDI: ZDI-25-343

SOURCES

db:ZDIid:ZDI-25-343
db:CNVDid:CNVD-2025-14951
db:JVNDBid:JVNDB-2025-013673
db:NVDid:CVE-2025-5824

LAST UPDATE DATE

2025-09-12T19:40:30.124000+00:00


SOURCES UPDATE DATE

db:ZDIid:ZDI-25-343date:2025-06-11T00:00:00
db:CNVDid:CNVD-2025-14951date:2025-07-03T00:00:00
db:JVNDBid:JVNDB-2025-013673date:2025-09-11T05:46:00
db:NVDid:CVE-2025-5824date:2025-09-10T14:46:54.780

SOURCES RELEASE DATE

db:ZDIid:ZDI-25-343date:2025-06-11T00:00:00
db:CNVDid:CNVD-2025-14951date:2025-07-03T00:00:00
db:JVNDBid:JVNDB-2025-013673date:2025-09-11T00:00:00
db:NVDid:CVE-2025-5824date:2025-06-25T18:15:23.173