DESCRIPTION

A vulnerability has been identified in TeleControl Server Basic (All versions < V3.1.2.2). The affected application is vulnerable to SQL injection through the internally used 'CreateTrace' method. This could allow an unauthenticated remote attacker to bypass authorization controls, to read from and write to the application's database and execute code with "NT AUTHORITY\NetworkService" permissions. A successful attack requires the attacker to be able to access port 8000 on a system where a vulnerable version of the affected application is executed on. (ZDI-CAN-25911). This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens TeleControl Server Basic. Authentication is not required to exploit this vulnerability.The specific flaw exists within the implementation of the CreateTrace method. The issue results from the lack of proper validation of a user-supplied string before using it to construct SQL queries. An attacker can leverage this vulnerability to execute code in the context of NETWORK SERVICE. Siemens TeleControl Server Basic versions prior to v3.1.2.2 have multiple SQL injection vulnerabilities that can be exploited by attackers to read and write the application's database, causing a denial of service and executing code in the operating system shell with limited "NT AUTHORITYNetworkService" permissions

Trust: 2.61

sources: NVD: CVE-2025-27495 // ZDI: ZDI-25-381 // CNVD: CNVD-2025-09149 // CNVD: CNVD-2025-08398

IOT TAXONOMY

category:['ICS']sub_category: -

Trust: 1.2

sources: CNVD: CNVD-2025-09149 // CNVD: CNVD-2025-08398

AFFECTED PRODUCTS

vendor:siemensmodel:telecontrol server basicscope:ltversion:v3.1.2.2

Trust: 1.2

vendor:siemensmodel:telecontrol server basicscope: - version: -

Trust: 0.7

sources: ZDI: ZDI-25-381 // CNVD: CNVD-2025-09149 // CNVD: CNVD-2025-08398

CVSS

SEVERITY

CVSSV2

CVSSV3

productcert@siemens.com: CVE-2025-27495
value: CRITICAL

Trust: 1.0

ZDI: CVE-2025-27495
value: CRITICAL

Trust: 0.7

CNVD: CNVD-2025-09149
value: HIGH

Trust: 0.6

CNVD: CNVD-2025-08398
value: HIGH

Trust: 0.6

CNVD: CNVD-2025-09149
severity: HIGH
baseScore: 10.0
vectorString: AV:N/AC:L/AU:N/C:C/I:C/A:C
accessVector: NETWORK
accessComplexity: LOW
authentication: NONE
confidentialityImpact: COMPLETE
integrityImpact: COMPLETE
availabilityImpact: COMPLETE
exploitabilityScore: 10.0
impactScore: 10.0
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.6

CNVD: CNVD-2025-08398
severity: HIGH
baseScore: 10.0
vectorString: AV:N/AC:L/AU:N/C:C/I:C/A:C
accessVector: NETWORK
accessComplexity: LOW
authentication: NONE
confidentialityImpact: COMPLETE
integrityImpact: COMPLETE
availabilityImpact: COMPLETE
exploitabilityScore: 10.0
impactScore: 10.0
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.6

productcert@siemens.com: CVE-2025-27495
baseSeverity: CRITICAL
baseScore: 9.8
vectorString: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
attackVector: NETWORK
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 3.9
impactScore: 5.9
version: 3.1

Trust: 1.0

ZDI: CVE-2025-27495
baseSeverity: CRITICAL
baseScore: 9.8
vectorString: AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
attackVector: NETWORK
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 3.9
impactScore: 5.9
version: 3.0

Trust: 0.7

sources: ZDI: ZDI-25-381 // CNVD: CNVD-2025-09149 // CNVD: CNVD-2025-08398 // NVD: CVE-2025-27495

PROBLEMTYPE DATA

problemtype:CWE-89

Trust: 1.0

sources: NVD: CVE-2025-27495

PATCH

title:Siemens has issued an update to correct this vulnerability.url:https://cert-portal.siemens.com/productcert/html/ssa-443402.html

Trust: 0.7

title:Patch for Siemens TeleControl Server Basic SQL Injection Vulnerability (CNVD-2025-09149)url:https://www.cnvd.org.cn/patchInfo/show/686321

Trust: 0.6

title:Patch for Siemens TeleControl Server Basic has multiple SQL injection vulnerabilitiesurl:https://www.cnvd.org.cn/patchInfo/show/684331

Trust: 0.6

sources: ZDI: ZDI-25-381 // CNVD: CNVD-2025-09149 // CNVD: CNVD-2025-08398

EXTERNAL IDS

db:NVDid:CVE-2025-27495

Trust: 2.3

db:SIEMENSid:SSA-443402

Trust: 2.2

db:ZDI_CANid:ZDI-CAN-25911

Trust: 0.7

db:ZDIid:ZDI-25-381

Trust: 0.7

db:CNVDid:CNVD-2025-09149

Trust: 0.6

db:CNVDid:CNVD-2025-08398

Trust: 0.6

sources: ZDI: ZDI-25-381 // CNVD: CNVD-2025-09149 // CNVD: CNVD-2025-08398 // NVD: CVE-2025-27495

REFERENCES

url:https://cert-portal.siemens.com/productcert/html/ssa-443402.html

Trust: 2.9

sources: ZDI: ZDI-25-381 // CNVD: CNVD-2025-09149 // CNVD: CNVD-2025-08398 // NVD: CVE-2025-27495

CREDITS

Anonymous

Trust: 0.7

sources: ZDI: ZDI-25-381

SOURCES

db:ZDIid:ZDI-25-381
db:CNVDid:CNVD-2025-09149
db:CNVDid:CNVD-2025-08398
db:NVDid:CVE-2025-27495

LAST UPDATE DATE

2025-06-18T19:33:55.136000+00:00


SOURCES UPDATE DATE

db:ZDIid:ZDI-25-381date:2025-06-16T00:00:00
db:CNVDid:CNVD-2025-09149date:2025-05-07T00:00:00
db:CNVDid:CNVD-2025-08398date:2025-04-25T00:00:00
db:NVDid:CVE-2025-27495date:2025-04-17T20:22:16.240

SOURCES RELEASE DATE

db:ZDIid:ZDI-25-381date:2025-06-16T00:00:00
db:CNVDid:CNVD-2025-09149date:2025-05-07T00:00:00
db:CNVDid:CNVD-2025-08398date:2025-04-16T00:00:00
db:NVDid:CVE-2025-27495date:2025-04-16T18:16:04.310