ID

VAR-202501-2163


CVE

CVE-2024-57483


TITLE

Shenzhen Tenda Technology Co.,Ltd.  of  i24  Classic buffer overflow vulnerability in firmware

Trust: 0.8

sources: JVNDB: JVNDB-2025-003526

DESCRIPTION

Tenda i24 V2.0.0.5 is vulnerable to Buffer Overflow in the addWifiMacFilter function. Shenzhen Tenda Technology Co.,Ltd. of i24 Firmware has a classic buffer overflow vulnerability.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state. An attacker can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

Trust: 2.16

sources: NVD: CVE-2024-57483 // JVNDB: JVNDB-2025-003526 // CNVD: CNVD-2025-09692

IOT TAXONOMY

category:['Network device']sub_category: -

Trust: 0.6

sources: CNVD: CNVD-2025-09692

AFFECTED PRODUCTS

vendor:tendamodel:i24scope:eqversion:2.0.0.5

Trust: 1.0

vendor:tendamodel:i24scope:eqversion:i24 firmware 2.0.0.5

Trust: 0.8

vendor:tendamodel:i24scope:eqversion: -

Trust: 0.8

vendor:tendamodel:i24scope: - version: -

Trust: 0.8

vendor:tendamodel:i24scope:eqversion:v2.0.0.5

Trust: 0.6

sources: CNVD: CNVD-2025-09692 // JVNDB: JVNDB-2025-003526 // NVD: CVE-2024-57483

CVSS

SEVERITY

CVSSV2

CVSSV3

134c704f-9b21-4f2e-91b3-4a467353bcc0: CVE-2024-57483
value: CRITICAL

Trust: 1.0

OTHER: JVNDB-2025-003526
value: CRITICAL

Trust: 0.8

CNVD: CNVD-2025-09692
value: HIGH

Trust: 0.6

CNVD: CNVD-2025-09692
severity: HIGH
baseScore: 10.0
vectorString: AV:N/AC:L/AU:N/C:C/I:C/A:C
accessVector: NETWORK
accessComplexity: LOW
authentication: NONE
confidentialityImpact: COMPLETE
integrityImpact: COMPLETE
availabilityImpact: COMPLETE
exploitabilityScore: 10.0
impactScore: 10.0
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.6

134c704f-9b21-4f2e-91b3-4a467353bcc0: CVE-2024-57483
baseSeverity: CRITICAL
baseScore: 9.8
vectorString: CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
attackVector: NETWORK
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 3.9
impactScore: 5.9
version: 3.1

Trust: 1.0

OTHER: JVNDB-2025-003526
baseSeverity: CRITICAL
baseScore: 9.8
vectorString: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
attackVector: NETWORK
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: NONE
impactScore: NONE
version: 3.0

Trust: 0.8

sources: CNVD: CNVD-2025-09692 // JVNDB: JVNDB-2025-003526 // NVD: CVE-2024-57483

PROBLEMTYPE DATA

problemtype:CWE-120

Trust: 1.0

problemtype:Classic buffer overflow (CWE-120) [ others ]

Trust: 0.8

sources: JVNDB: JVNDB-2025-003526 // NVD: CVE-2024-57483

EXTERNAL IDS

db:NVDid:CVE-2024-57483

Trust: 3.2

db:JVNDBid:JVNDB-2025-003526

Trust: 0.8

db:CNVDid:CNVD-2025-09692

Trust: 0.6

sources: CNVD: CNVD-2025-09692 // JVNDB: JVNDB-2025-003526 // NVD: CVE-2024-57483

REFERENCES

url:http://tenda.com

Trust: 1.8

url:https://nvd.nist.gov/vuln/detail/cve-2024-57483

Trust: 1.4

url:https://gist.github.com/xiaocurry/7dd5c6ab5af9df49883535b997cef7a4

Trust: 1.0

sources: CNVD: CNVD-2025-09692 // JVNDB: JVNDB-2025-003526 // NVD: CVE-2024-57483

SOURCES

db:CNVDid:CNVD-2025-09692
db:JVNDBid:JVNDB-2025-003526
db:NVDid:CVE-2024-57483

LAST UPDATE DATE

2025-05-15T23:17:27.035000+00:00


SOURCES UPDATE DATE

db:CNVDid:CNVD-2025-09692date:2025-05-14T00:00:00
db:JVNDBid:JVNDB-2025-003526date:2025-04-16T07:10:00
db:NVDid:CVE-2024-57483date:2025-04-09T18:32:38.667

SOURCES RELEASE DATE

db:CNVDid:CNVD-2025-09692date:2025-05-13T00:00:00
db:JVNDBid:JVNDB-2025-003526date:2025-04-16T00:00:00
db:NVDid:CVE-2024-57483date:2025-01-14T23:15:09.060