ID

VAR-202412-0348


CVE

CVE-2024-53041


TITLE

Siemens Tecnomatix Plant Simulation WRL File Parsing Stack-based Buffer Overflow Remote Code Execution Vulnerability

Trust: 0.7

sources: ZDI: ZDI-25-059

DESCRIPTION

A vulnerability has been identified in Teamcenter Visualization V14.2 (All versions < V14.2.0.14), Teamcenter Visualization V14.3 (All versions < V14.3.0.12), Teamcenter Visualization V2312 (All versions < V2312.0008), Tecnomatix Plant Simulation V2302 (All versions < V2302.0016), Tecnomatix Plant Simulation V2404 (All versions < V2404.0005). The affected applications contain a stack based overflow vulnerability while parsing specially crafted WRL files. This could allow an attacker to execute code in the context of the current process. (ZDI-CAN-25000). This vulnerability allows remote attackers to execute arbitrary code on affected installations of Siemens Tecnomatix Plant Simulation. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the parsing of WRL files in the wrltojt module. The issue results from the lack of proper validation of the length of user-supplied data prior to copying it to a fixed-length stack-based buffer. Siemens Teamcenter Visualization is a software that provides team collaboration capabilities for designing 2D and 3D scenes. The software simplifies engineering and manufacturing processes by creating virtual prototypes from a variety of mechanical computer-aided design (MCAD) formats. Siemens Tecnomatix Plant Simulation is an industrial control device. Use the power of discrete event simulation to analyze and optimize production volume and improve manufacturing system performance

Trust: 2.07

sources: NVD: CVE-2024-53041 // ZDI: ZDI-25-059 // CNVD: CNVD-2025-02597

IOT TAXONOMY

category:['ICS']sub_category: -

Trust: 0.6

sources: CNVD: CNVD-2025-02597

AFFECTED PRODUCTS

vendor:siemensmodel:tecnomatix plant simulationscope: - version: -

Trust: 0.7

vendor:siemensmodel:tecnomatix plant simulationscope:eqversion:v2302<v2302.0016

Trust: 0.6

vendor:siemensmodel:tecnomatix plant simulationscope:eqversion:v2404<v2404.0005

Trust: 0.6

vendor:siemensmodel:teamcenter visualizationscope:eqversion:v14.2<v14.2.0.14

Trust: 0.6

vendor:siemensmodel:teamcenter visualizationscope:eqversion:v14.3<v14.3.0.12

Trust: 0.6

vendor:siemensmodel:teamcenter visualizationscope:eqversion:v2312<v2312.0008

Trust: 0.6

vendor:siemensmodel:teamcenter visualizationscope:eqversion:v2406<v2406.0005

Trust: 0.6

sources: ZDI: ZDI-25-059 // CNVD: CNVD-2025-02597

CVSS

SEVERITY

CVSSV2

CVSSV3

productcert@siemens.com: CVE-2024-53041
value: HIGH

Trust: 1.0

ZDI: CVE-2024-53041
value: HIGH

Trust: 0.7

CNVD: CNVD-2025-02597
value: HIGH

Trust: 0.6

CNVD: CNVD-2025-02597
severity: HIGH
baseScore: 7.2
vectorString: AV:L/AC:L/AU:N/C:C/I:C/A:C
accessVector: LOCAL
accessComplexity: LOW
authentication: NONE
confidentialityImpact: COMPLETE
integrityImpact: COMPLETE
availabilityImpact: COMPLETE
exploitabilityScore: 3.9
impactScore: 10.0
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.6

productcert@siemens.com: CVE-2024-53041
baseSeverity: HIGH
baseScore: 7.8
vectorString: CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
attackVector: LOCAL
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: REQUIRED
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 1.8
impactScore: 5.9
version: 3.1

Trust: 1.0

ZDI: CVE-2024-53041
baseSeverity: HIGH
baseScore: 7.8
vectorString: AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
attackVector: LOCAL
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: REQUIRED
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 1.8
impactScore: 5.9
version: 3.0

Trust: 0.7

sources: ZDI: ZDI-25-059 // CNVD: CNVD-2025-02597 // NVD: CVE-2024-53041

PROBLEMTYPE DATA

problemtype:CWE-121

Trust: 1.0

sources: NVD: CVE-2024-53041

PATCH

title:Siemens has issued an update to correct this vulnerability.url:https://cert-portal.siemens.com/productcert/html/ssa-583523.html

Trust: 0.7

title:Patch for Siemens Teamcenter Visualization/Tecnomatix Plant Simulation Buffer Overflow Vulnerabilityurl:https://www.cnvd.org.cn/patchInfo/show/654596

Trust: 0.6

sources: ZDI: ZDI-25-059 // CNVD: CNVD-2025-02597

EXTERNAL IDS

db:NVDid:CVE-2024-53041

Trust: 2.3

db:SIEMENSid:SSA-583523

Trust: 1.6

db:SIEMENSid:SSA-645131

Trust: 1.0

db:ZDI_CANid:ZDI-CAN-25000

Trust: 0.7

db:ZDIid:ZDI-25-059

Trust: 0.7

db:CNVDid:CNVD-2025-02597

Trust: 0.6

sources: ZDI: ZDI-25-059 // CNVD: CNVD-2025-02597 // NVD: CVE-2024-53041

REFERENCES

url:https://cert-portal.siemens.com/productcert/html/ssa-583523.html

Trust: 2.3

url:https://cert-portal.siemens.com/productcert/html/ssa-645131.html

Trust: 1.0

sources: ZDI: ZDI-25-059 // CNVD: CNVD-2025-02597 // NVD: CVE-2024-53041

CREDITS

Rocco Calvi (@TecR0c) with TecSecurity

Trust: 0.7

sources: ZDI: ZDI-25-059

SOURCES

db:ZDIid:ZDI-25-059
db:CNVDid:CNVD-2025-02597
db:NVDid:CVE-2024-53041

LAST UPDATE DATE

2025-02-09T21:18:25.521000+00:00


SOURCES UPDATE DATE

db:ZDIid:ZDI-25-059date:2025-01-22T00:00:00
db:CNVDid:CNVD-2025-02597date:2025-02-08T00:00:00
db:NVDid:CVE-2024-53041date:2024-12-10T14:30:46.507

SOURCES RELEASE DATE

db:ZDIid:ZDI-25-059date:2025-01-22T00:00:00
db:CNVDid:CNVD-2025-02597date:2025-02-08T00:00:00
db:NVDid:CVE-2024-53041date:2024-12-10T14:30:46.507