ID

VAR-202411-3527


CVE

CVE-2024-45884


TITLE

DrayTek Corporation  of  Vigor3900  in the firmware  OS  Command injection vulnerability

Trust: 0.8

sources: JVNDB: JVNDB-2024-021876

DESCRIPTION

DrayTek Vigor3900 1.5.1.3 contains a post-authentication command injection vulnerability. This vulnerability occurs when the `action` parameter in `cgi-bin/mainfunction.cgi` is set to `setSWMGroup.`. DrayTek Corporation of Vigor3900 The firmware has OS A command injection vulnerability exists.Information is obtained, information is tampered with, and service operation is interrupted. (DoS) It may be in a state

Trust: 1.62

sources: NVD: CVE-2024-45884 // JVNDB: JVNDB-2024-021876

AFFECTED PRODUCTS

vendor:draytekmodel:vigor3900scope:eqversion:1.5.1.3

Trust: 1.0

vendor:draytekmodel:vigor3900scope:eqversion: -

Trust: 0.8

vendor:draytekmodel:vigor3900scope:eqversion:vigor3900 firmware 1.5.1.3

Trust: 0.8

vendor:draytekmodel:vigor3900scope: - version: -

Trust: 0.8

sources: JVNDB: JVNDB-2024-021876 // NVD: CVE-2024-45884

CVSS

SEVERITY

CVSSV2

CVSSV3

134c704f-9b21-4f2e-91b3-4a467353bcc0: CVE-2024-45884
value: HIGH

Trust: 1.0

OTHER: JVNDB-2024-021876
value: HIGH

Trust: 0.8

134c704f-9b21-4f2e-91b3-4a467353bcc0: CVE-2024-45884
baseSeverity: HIGH
baseScore: 8.0
vectorString: CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
attackVector: ADJACENT
attackComplexity: LOW
privilegesRequired: LOW
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 2.1
impactScore: 5.9
version: 3.1

Trust: 1.0

OTHER: JVNDB-2024-021876
baseSeverity: HIGH
baseScore: 8.0
vectorString: CVSS:3.0/AV:A/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
attackVector: ADJACENT NETWORK
attackComplexity: LOW
privilegesRequired: LOW
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: NONE
impactScore: NONE
version: 3.0

Trust: 0.8

sources: JVNDB: JVNDB-2024-021876 // NVD: CVE-2024-45884

PROBLEMTYPE DATA

problemtype:CWE-78

Trust: 1.0

problemtype:OS Command injection (CWE-78) [ others ]

Trust: 0.8

sources: JVNDB: JVNDB-2024-021876 // NVD: CVE-2024-45884

EXTERNAL IDS

db:NVDid:CVE-2024-45884

Trust: 2.6

db:JVNDBid:JVNDB-2024-021876

Trust: 0.8

sources: JVNDB: JVNDB-2024-021876 // NVD: CVE-2024-45884

REFERENCES

url:https://github.com/fu37kola/cve/blob/main/draytek/vigor3900/1.5.1.3/draytek_vigor_3900_1.5.1.3.pdf

Trust: 1.0

url:https://github.com/n1neman/wp/blob/main/test_v.zip

Trust: 1.0

url:https://nvd.nist.gov/vuln/detail/cve-2024-45884

Trust: 0.8

sources: JVNDB: JVNDB-2024-021876 // NVD: CVE-2024-45884

SOURCES

db:JVNDBid:JVNDB-2024-021876
db:NVDid:CVE-2024-45884

LAST UPDATE DATE

2025-04-12T23:32:27.379000+00:00


SOURCES UPDATE DATE

db:JVNDBid:JVNDB-2024-021876date:2025-04-11T02:23:00
db:NVDid:CVE-2024-45884date:2025-04-10T15:52:58.353

SOURCES RELEASE DATE

db:JVNDBid:JVNDB-2024-021876date:2025-04-11T00:00:00
db:NVDid:CVE-2024-45884date:2024-11-04T15:15:21.937