ID

VAR-202404-1726


CVE

CVE-2024-33212


TITLE

Shenzhen Tenda Technology Co.,Ltd.  of  fh1206  Stack-based buffer overflow vulnerability in firmware

Trust: 0.8

sources: JVNDB: JVNDB-2024-020816

DESCRIPTION

Tenda FH1206 V1.2.0.8(8155)_EN was discovered to contain a stack-based buffer overflow vulnerability via the funcpara1 parameter in ip/goform/setcfm. Shenzhen Tenda Technology Co.,Ltd. (DoS) It may be in a state. Attackers can exploit this vulnerability to execute arbitrary code on the system or cause a denial of service

Trust: 2.16

sources: NVD: CVE-2024-33212 // JVNDB: JVNDB-2024-020816 // CNVD: CNVD-2025-11914

IOT TAXONOMY

category:['Network device']sub_category: -

Trust: 0.6

sources: CNVD: CNVD-2025-11914

AFFECTED PRODUCTS

vendor:tendamodel:fh1206scope:eqversion:1.2.0.8\(8155\)

Trust: 1.0

vendor:tendamodel:fh1206scope:eqversion:fh1206 firmware 1.2.0.8(8155)

Trust: 0.8

vendor:tendamodel:fh1206scope:eqversion: -

Trust: 0.8

vendor:tendamodel:fh1206scope: - version: -

Trust: 0.8

vendor:tendamodel:fh1206 v1.2.0.8 enscope: - version: -

Trust: 0.6

sources: CNVD: CNVD-2025-11914 // JVNDB: JVNDB-2024-020816 // NVD: CVE-2024-33212

CVSS

SEVERITY

CVSSV2

CVSSV3

134c704f-9b21-4f2e-91b3-4a467353bcc0: CVE-2024-33212
value: HIGH

Trust: 1.0

OTHER: JVNDB-2024-020816
value: HIGH

Trust: 0.8

CNVD: CNVD-2025-11914
value: HIGH

Trust: 0.6

CNVD: CNVD-2025-11914
severity: HIGH
baseScore: 8.3
vectorString: AV:A/AC:L/AU:N/C:C/I:C/A:C
accessVector: ADJACENT_NETWORK
accessComplexity: LOW
authentication: NONE
confidentialityImpact: COMPLETE
integrityImpact: COMPLETE
availabilityImpact: COMPLETE
exploitabilityScore: 6.5
impactScore: 10.0
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.6

134c704f-9b21-4f2e-91b3-4a467353bcc0: CVE-2024-33212
baseSeverity: HIGH
baseScore: 8.8
vectorString: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
attackVector: ADJACENT
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 2.8
impactScore: 5.9
version: 3.1

Trust: 1.0

OTHER: JVNDB-2024-020816
baseSeverity: HIGH
baseScore: 8.8
vectorString: CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
attackVector: ADJACENT NETWORK
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: NONE
impactScore: NONE
version: 3.0

Trust: 0.8

sources: CNVD: CNVD-2025-11914 // JVNDB: JVNDB-2024-020816 // NVD: CVE-2024-33212

PROBLEMTYPE DATA

problemtype:CWE-121

Trust: 1.0

problemtype:Stack-based buffer overflow (CWE-121) [ others ]

Trust: 0.8

sources: JVNDB: JVNDB-2024-020816 // NVD: CVE-2024-33212

EXTERNAL IDS

db:NVDid:CVE-2024-33212

Trust: 3.2

db:JVNDBid:JVNDB-2024-020816

Trust: 0.8

db:CNVDid:CNVD-2025-11914

Trust: 0.6

sources: CNVD: CNVD-2025-11914 // JVNDB: JVNDB-2024-020816 // NVD: CVE-2024-33212

REFERENCES

url:https://palm-vertebra-fe9.notion.site/formsetcfm-7d199da0fd0740988a498304905e2dd1

Trust: 2.4

url:https://nvd.nist.gov/vuln/detail/cve-2024-33212

Trust: 0.8

sources: CNVD: CNVD-2025-11914 // JVNDB: JVNDB-2024-020816 // NVD: CVE-2024-33212

SOURCES

db:CNVDid:CNVD-2025-11914
db:JVNDBid:JVNDB-2024-020816
db:NVDid:CVE-2024-33212

LAST UPDATE DATE

2025-06-09T23:21:47.652000+00:00


SOURCES UPDATE DATE

db:CNVDid:CNVD-2025-11914date:2025-06-06T00:00:00
db:JVNDBid:JVNDB-2024-020816date:2025-03-24T09:16:00
db:NVDid:CVE-2024-33212date:2025-03-17T14:44:45.820

SOURCES RELEASE DATE

db:CNVDid:CNVD-2025-11914date:2025-06-06T00:00:00
db:JVNDBid:JVNDB-2024-020816date:2025-03-24T00:00:00
db:NVDid:CVE-2024-33212date:2024-04-23T15:15:50.090