ID

VAR-202403-1699


CVE

CVE-2024-30585


TITLE

Shenzhen Tenda Technology Co.,Ltd.  of  FH1202  Stack-based buffer overflow vulnerability in firmware

Trust: 0.8

sources: JVNDB: JVNDB-2024-020471

DESCRIPTION

Tenda FH1202 v1.2.0.14(408) has a stack overflow vulnerability in the deviceId parameter of the saveParentControlInfo function. Shenzhen Tenda Technology Co.,Ltd. of FH1202 A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state

Trust: 1.62

sources: NVD: CVE-2024-30585 // JVNDB: JVNDB-2024-020471

AFFECTED PRODUCTS

vendor:tendamodel:fh1202scope:eqversion:1.2.0.14\(408\)

Trust: 1.0

vendor:tendamodel:fh1202scope:eqversion: -

Trust: 0.8

vendor:tendamodel:fh1202scope: - version: -

Trust: 0.8

vendor:tendamodel:fh1202scope:eqversion:fh1202 firmware 1.2.0.14(408)

Trust: 0.8

sources: JVNDB: JVNDB-2024-020471 // NVD: CVE-2024-30585

CVSS

SEVERITY

CVSSV2

CVSSV3

134c704f-9b21-4f2e-91b3-4a467353bcc0: CVE-2024-30585
value: MEDIUM

Trust: 1.0

OTHER: JVNDB-2024-020471
value: MEDIUM

Trust: 0.8

134c704f-9b21-4f2e-91b3-4a467353bcc0: CVE-2024-30585
baseSeverity: MEDIUM
baseScore: 6.5
vectorString: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
attackVector: ADJACENT
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: NONE
integrityImpact: NONE
availabilityImpact: HIGH
exploitabilityScore: 2.8
impactScore: 3.6
version: 3.1

Trust: 1.0

OTHER: JVNDB-2024-020471
baseSeverity: MEDIUM
baseScore: 6.5
vectorString: CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
attackVector: ADJACENT NETWORK
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: NONE
integrityImpact: NONE
availabilityImpact: HIGH
exploitabilityScore: NONE
impactScore: NONE
version: 3.0

Trust: 0.8

sources: JVNDB: JVNDB-2024-020471 // NVD: CVE-2024-30585

PROBLEMTYPE DATA

problemtype:CWE-121

Trust: 1.0

problemtype:Stack-based buffer overflow (CWE-121) [ others ]

Trust: 0.8

sources: JVNDB: JVNDB-2024-020471 // NVD: CVE-2024-30585

EXTERNAL IDS

db:NVDid:CVE-2024-30585

Trust: 2.6

db:JVNDBid:JVNDB-2024-020471

Trust: 0.8

sources: JVNDB: JVNDB-2024-020471 // NVD: CVE-2024-30585

REFERENCES

url:https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/fh/fh1202/saveparentcontrolinfo_deviceid.md

Trust: 1.0

url:https://nvd.nist.gov/vuln/detail/cve-2024-30585

Trust: 0.8

sources: JVNDB: JVNDB-2024-020471 // NVD: CVE-2024-30585

SOURCES

db:JVNDBid:JVNDB-2024-020471
db:NVDid:CVE-2024-30585

LAST UPDATE DATE

2025-03-15T23:19:49.961000+00:00


SOURCES UPDATE DATE

db:JVNDBid:JVNDB-2024-020471date:2025-03-14T05:50:00
db:NVDid:CVE-2024-30585date:2025-03-13T17:41:17.323

SOURCES RELEASE DATE

db:JVNDBid:JVNDB-2024-020471date:2025-03-14T00:00:00
db:NVDid:CVE-2024-30585date:2024-03-28T14:15:15.090