ID

VAR-202403-1539


CVE

CVE-2024-28547


TITLE

Shenzhen Tenda Technology Co.,Ltd.  of  AC18  Stack-based buffer overflow vulnerability in firmware

Trust: 0.8

sources: JVNDB: JVNDB-2024-020762

DESCRIPTION

Tenda AC18 V15.03.05.05 has a stack overflow vulnerability in the firewallEn parameter of formSetFirewallCfg function. Shenzhen Tenda Technology Co.,Ltd. of AC18 A stack-based buffer overflow vulnerability exists in the firmware.Service operation interruption (DoS) It may be in a state

Trust: 1.62

sources: NVD: CVE-2024-28547 // JVNDB: JVNDB-2024-020762

AFFECTED PRODUCTS

vendor:tendamodel:ac18scope:eqversion:15.03.05.05

Trust: 1.0

vendor:tendamodel:ac18scope:eqversion:ac18 firmware 15.03.05.05

Trust: 0.8

vendor:tendamodel:ac18scope: - version: -

Trust: 0.8

vendor:tendamodel:ac18scope:eqversion: -

Trust: 0.8

sources: JVNDB: JVNDB-2024-020762 // NVD: CVE-2024-28547

CVSS

SEVERITY

CVSSV2

CVSSV3

134c704f-9b21-4f2e-91b3-4a467353bcc0: CVE-2024-28547
value: MEDIUM

Trust: 1.0

OTHER: JVNDB-2024-020762
value: MEDIUM

Trust: 0.8

134c704f-9b21-4f2e-91b3-4a467353bcc0: CVE-2024-28547
baseSeverity: MEDIUM
baseScore: 6.5
vectorString: CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
attackVector: ADJACENT
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: NONE
integrityImpact: NONE
availabilityImpact: HIGH
exploitabilityScore: 2.8
impactScore: 3.6
version: 3.1

Trust: 1.0

OTHER: JVNDB-2024-020762
baseSeverity: MEDIUM
baseScore: 6.5
vectorString: CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
attackVector: ADJACENT NETWORK
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: NONE
integrityImpact: NONE
availabilityImpact: HIGH
exploitabilityScore: NONE
impactScore: NONE
version: 3.0

Trust: 0.8

sources: JVNDB: JVNDB-2024-020762 // NVD: CVE-2024-28547

PROBLEMTYPE DATA

problemtype:CWE-121

Trust: 1.0

problemtype:Stack-based buffer overflow (CWE-121) [ others ]

Trust: 0.8

sources: JVNDB: JVNDB-2024-020762 // NVD: CVE-2024-28547

EXTERNAL IDS

db:NVDid:CVE-2024-28547

Trust: 2.6

db:JVNDBid:JVNDB-2024-020762

Trust: 0.8

sources: JVNDB: JVNDB-2024-020762 // NVD: CVE-2024-28547

REFERENCES

url:https://github.com/abcdefg-png/iot-vulnerable/blob/main/tenda/ac18/formsetfirewallcfg.md

Trust: 1.8

url:https://nvd.nist.gov/vuln/detail/cve-2024-28547

Trust: 0.8

sources: JVNDB: JVNDB-2024-020762 // NVD: CVE-2024-28547

SOURCES

db:JVNDBid:JVNDB-2024-020762
db:NVDid:CVE-2024-28547

LAST UPDATE DATE

2025-03-25T23:02:44.543000+00:00


SOURCES UPDATE DATE

db:JVNDBid:JVNDB-2024-020762date:2025-03-24T06:10:00
db:NVDid:CVE-2024-28547date:2025-03-13T19:47:29.850

SOURCES RELEASE DATE

db:JVNDBid:JVNDB-2024-020762date:2025-03-24T00:00:00
db:NVDid:CVE-2024-28547date:2024-03-18T14:15:10.010