ID

VAR-201811-0133


CVE

CVE-2018-13320


TITLE

Buffalo TS5600D1206 Command Injection Vulnerability

Trust: 2.0

sources: CNVD: CNVD-2019-00672 // JVNDB: JVNDB-2018-012806 // CNNVD: CNNVD-201811-726

DESCRIPTION

System Command Injection in network.set_auth_settings in Buffalo TS5600D1206 version 3.70-0.10 allows attackers to execute system commands via the adminUsername and adminPassword parameters. Buffalo TS5600D1206 Contains a command injection vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. The Buffalo TS5600D1206 is a network storage device from the Buffalo Group in Japan

Trust: 2.25

sources: NVD: CVE-2018-13320 // JVNDB: JVNDB-2018-012806 // CNVD: CNVD-2019-00672 // VULHUB: VHN-123368

IOT TAXONOMY

category:['Network device']sub_category: -

Trust: 0.6

sources: CNVD: CNVD-2019-00672

AFFECTED PRODUCTS

vendor:buffalomodel:ts5600d1206scope:eqversion:3.61-0.10

Trust: 1.6

vendor:buffalomodel:ts5600d1206scope:eqversion:3.70-0.10

Trust: 1.4

sources: CNVD: CNVD-2019-00672 // JVNDB: JVNDB-2018-012806 // CNNVD: CNNVD-201811-726 // NVD: CVE-2018-13320

CVSS

SEVERITY

CVSSV2

CVSSV3

nvd@nist.gov: CVE-2018-13320
value: HIGH

Trust: 1.0

NVD: CVE-2018-13320
value: HIGH

Trust: 0.8

CNVD: CNVD-2019-00672
value: MEDIUM

Trust: 0.6

CNNVD: CNNVD-201811-726
value: HIGH

Trust: 0.6

VULHUB: VHN-123368
value: MEDIUM

Trust: 0.1

nvd@nist.gov: CVE-2018-13320
severity: MEDIUM
baseScore: 6.5
vectorString: AV:N/AC:L/AU:S/C:P/I:P/A:P
accessVector: NETWORK
accessComplexity: LOW
authentication: SINGLE
confidentialityImpact: PARTIAL
integrityImpact: PARTIAL
availabilityImpact: PARTIAL
exploitabilityScore: 8.0
impactScore: 6.4
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 1.8

CNVD: CNVD-2019-00672
severity: MEDIUM
baseScore: 5.1
vectorString: AV:N/AC:H/AU:N/C:P/I:P/A:P
accessVector: NETWORK
accessComplexity: HIGH
authentication: NONE
confidentialityImpact: PARTIAL
integrityImpact: PARTIAL
availabilityImpact: PARTIAL
exploitabilityScore: 4.9
impactScore: 6.4
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.6

VULHUB: VHN-123368
severity: MEDIUM
baseScore: 6.5
vectorString: AV:N/AC:L/AU:S/C:P/I:P/A:P
accessVector: NETWORK
accessComplexity: LOW
authentication: SINGLE
confidentialityImpact: PARTIAL
integrityImpact: PARTIAL
availabilityImpact: PARTIAL
exploitabilityScore: 8.0
impactScore: 6.4
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.1

nvd@nist.gov: CVE-2018-13320
baseSeverity: HIGH
baseScore: 7.2
vectorString: CVSS:3.0/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
attackVector: NETWORK
attackComplexity: LOW
privilegesRequired: HIGH
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 1.2
impactScore: 5.9
version: 3.0

Trust: 1.8

sources: CNVD: CNVD-2019-00672 // VULHUB: VHN-123368 // JVNDB: JVNDB-2018-012806 // CNNVD: CNNVD-201811-726 // NVD: CVE-2018-13320

PROBLEMTYPE DATA

problemtype:CWE-78

Trust: 1.1

problemtype:CWE-77

Trust: 0.8

sources: VULHUB: VHN-123368 // JVNDB: JVNDB-2018-012806 // NVD: CVE-2018-13320

THREAT TYPE

remote

Trust: 0.6

sources: CNNVD: CNNVD-201811-726

TYPE

operating system commend injection

Trust: 0.6

sources: CNNVD: CNNVD-201811-726

CONFIGURATIONS

sources: JVNDB: JVNDB-2018-012806

PATCH

title:Replacement Hard Drives for TeraStation 3000 and 5000 Seriesurl:https://www.buffalotech.com/products/replacement-hard-drives-for-terastation-3000-and-5000-series

Trust: 0.8

sources: JVNDB: JVNDB-2018-012806

EXTERNAL IDS

db:NVDid:CVE-2018-13320

Trust: 3.1

db:JVNDBid:JVNDB-2018-012806

Trust: 0.8

db:CNNVDid:CNNVD-201811-726

Trust: 0.7

db:CNVDid:CNVD-2019-00672

Trust: 0.6

db:VULHUBid:VHN-123368

Trust: 0.1

sources: CNVD: CNVD-2019-00672 // VULHUB: VHN-123368 // JVNDB: JVNDB-2018-012806 // CNNVD: CNNVD-201811-726 // NVD: CVE-2018-13320

REFERENCES

url:https://blog.securityevaluators.com/buffalo-terastation-ts5600d1206-nas-cve-disclosure-ab5d159f036d

Trust: 2.5

url:https://nvd.nist.gov/vuln/detail/cve-2018-13320

Trust: 1.4

url:https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-13320

Trust: 0.8

sources: CNVD: CNVD-2019-00672 // VULHUB: VHN-123368 // JVNDB: JVNDB-2018-012806 // CNNVD: CNNVD-201811-726 // NVD: CVE-2018-13320

SOURCES

db:CNVDid:CNVD-2019-00672
db:VULHUBid:VHN-123368
db:JVNDBid:JVNDB-2018-012806
db:CNNVDid:CNNVD-201811-726
db:NVDid:CVE-2018-13320

LAST UPDATE DATE

2024-11-23T22:06:29.359000+00:00


SOURCES UPDATE DATE

db:CNVDid:CNVD-2019-00672date:2019-01-09T00:00:00
db:VULHUBid:VHN-123368date:2019-10-03T00:00:00
db:JVNDBid:JVNDB-2018-012806date:2019-02-07T00:00:00
db:CNNVDid:CNNVD-201811-726date:2019-10-23T00:00:00
db:NVDid:CVE-2018-13320date:2024-11-21T03:46:52.357

SOURCES RELEASE DATE

db:CNVDid:CNVD-2019-00672date:2019-01-09T00:00:00
db:VULHUBid:VHN-123368date:2018-11-26T00:00:00
db:JVNDBid:JVNDB-2018-012806date:2019-02-07T00:00:00
db:CNNVDid:CNNVD-201811-726date:2018-11-27T00:00:00
db:NVDid:CVE-2018-13320date:2018-11-26T23:29:00.610