ID

VAR-201810-1414


CVE

CVE-2018-5400


TITLE

Auto-Maskin DCU 210E RP 210E and Marine Pro Observer App

Trust: 0.8

sources: CERT/CC: VU#176301

DESCRIPTION

The Auto-Maskin products utilize an undocumented custom protocol to set up Modbus communications with other devices without validating those devices. The originating device sends a message in plaintext, 48:65:6c:6c:6f:20:57:6f:72:6c:64, "Hello World" over UDP ports 44444-44446 to the broadcast address for the LAN. Without verification devices respond to any of these broadcast messages on the LAN with a plaintext reply over UDP containing the device model and firmware version. Following this exchange the devices allow Modbus transmissions between the two devices on the standard Modbus port 502 TCP. Impact: An attacker can exploit this vulnerability to send arbitrary messages to any DCU or RP device through spoofing or replay attacks as long as they have access to the network. Affected releases are Auto-Maskin DCU-210E RP-210E: Versions prior to 3.7 on ARMv7. Auto-Maskin RP With remote panel DCU The control unit is a product that monitors and controls the ship's engine. These products have multiple vulnerabilities related to authentication and encryption that can be accessed by an attacker and take over the engine operation of the ship. Problems with hard-coded credentials (CWE-798) - CVE-2018-5399 DCU 210E No firmware Dropbear SSH server Is included, but this is not documented. Also, SSH The username and password for the connection are hard-coded and the password is easily guessable. Insufficient validation of connection source (CWE-346) - CVE-2018-5400 The product uses a proprietary protocol that is not documented to communicate with other equipment. Modbus We are communicating, but we have not verified the validity of the connection between devices. Sensitive information is sent in clear text (CWE-319) - CVE-2018-5401 The product is not encrypted Modbus Sending control information using communication. Sensitive information is sent in clear text (CWE-319) - CVE-2018-5402 The web server included in the product is an administrator using plain text that is not encrypted. PIN Sending code. These vulnerabilities Brian Satira Mr and Brian Olson Reported by him.An attacker could use this vulnerability to obtain information such as device configuration, configuration information, and sensor operating status. Also any Modbus ( control ) Information may also be sent. Auto-Maskin DCU 210E RP 210E and Marine Pro Observer App are prone to the following security vulnerabilities: 1. An hard-coded credentials security bypass Vulnerability. 2. A security-bypass vulnerability. 3. Multiple information disclosure vulnerabilities. Attackers may exploit these issues to gain unauthorized access to the affected application, or to bypass certain security restrictions to perform unauthorized actions, and obtain sensitive information

Trust: 2.7

sources: NVD: CVE-2018-5400 // CERT/CC: VU#176301 // JVNDB: JVNDB-2018-008149 // BID: 105714 // VULHUB: VHN-135431

AFFECTED PRODUCTS

vendor:auto maskinmodel:rp 210escope:eqversion: -

Trust: 1.0

vendor:auto maskinmodel:dcu 210escope:eqversion: -

Trust: 1.0

vendor:auto maskin asmodel: - scope: - version: -

Trust: 0.8

vendor:auto maskinmodel:dcu 210escope: - version: -

Trust: 0.8

vendor:auto maskinmodel:marine pro observerscope: - version: -

Trust: 0.8

vendor:auto maskinmodel:rp 210escope: - version: -

Trust: 0.8

vendor:auto maskinmodel:as marine pro observerscope:eqversion:0

Trust: 0.3

vendor:auto maskinmodel:as dcu 210e rp 210escope:eqversion:0

Trust: 0.3

sources: CERT/CC: VU#176301 // BID: 105714 // JVNDB: JVNDB-2018-008149 // NVD: CVE-2018-5400

CVSS

SEVERITY

CVSSV2

CVSSV3

nvd@nist.gov: CVE-2018-5400
value: CRITICAL

Trust: 1.0

cret@cert.org: CVE-2018-5400
value: CRITICAL

Trust: 1.0

CNNVD: CNNVD-201810-260
value: CRITICAL

Trust: 0.6

VULHUB: VHN-135431
value: MEDIUM

Trust: 0.1

nvd@nist.gov: CVE-2018-5400
severity: MEDIUM
baseScore: 6.4
vectorString: AV:N/AC:L/AU:N/C:P/I:P/A:N
accessVector: NETWORK
accessComplexity: LOW
authentication: NONE
confidentialityImpact: PARTIAL
integrityImpact: PARTIAL
availabilityImpact: NONE
exploitabilityScore: 10.0
impactScore: 4.9
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 1.0

VULHUB: VHN-135431
severity: MEDIUM
baseScore: 6.4
vectorString: AV:N/AC:L/AU:N/C:P/I:P/A:N
accessVector: NETWORK
accessComplexity: LOW
authentication: NONE
confidentialityImpact: PARTIAL
integrityImpact: PARTIAL
availabilityImpact: NONE
exploitabilityScore: 10.0
impactScore: 4.9
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.1

nvd@nist.gov: CVE-2018-5400
baseSeverity: CRITICAL
baseScore: 9.1
vectorString: CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
attackVector: NETWORK
attackComplexity: LOW
privilegesRequired: NONE
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: NONE
exploitabilityScore: 3.9
impactScore: 5.2
version: 3.0

Trust: 2.0

sources: VULHUB: VHN-135431 // CNNVD: CNNVD-201810-260 // NVD: CVE-2018-5400 // NVD: CVE-2018-5400

PROBLEMTYPE DATA

problemtype:CWE-346

Trust: 1.1

sources: VULHUB: VHN-135431 // NVD: CVE-2018-5400

THREAT TYPE

remote

Trust: 0.6

sources: CNNVD: CNNVD-201810-260

TYPE

access control error

Trust: 0.6

sources: CNNVD: CNNVD-201810-260

CONFIGURATIONS

sources: JVNDB: JVNDB-2018-008149

EXTERNAL IDS

db:CERT/CCid:VU#176301

Trust: 3.6

db:NVDid:CVE-2018-5400

Trust: 2.8

db:ICS CERTid:ICSA-20-051-04

Trust: 1.7

db:JVNid:JVNVU99039923

Trust: 0.8

db:JVNDBid:JVNDB-2018-008149

Trust: 0.8

db:CNNVDid:CNNVD-201810-260

Trust: 0.7

db:AUSCERTid:ESB-2020.0648

Trust: 0.6

db:BIDid:105714

Trust: 0.3

db:VULHUBid:VHN-135431

Trust: 0.1

sources: CERT/CC: VU#176301 // VULHUB: VHN-135431 // BID: 105714 // JVNDB: JVNDB-2018-008149 // CNNVD: CNNVD-201810-260 // NVD: CVE-2018-5400

REFERENCES

url:https://www.kb.cert.org/vuls/id/176301

Trust: 2.8

url:https://www.us-cert.gov/ics/advisories/icsa-20-051-04

Trust: 1.7

url:about vulnerability notes

Trust: 0.8

url:contact us about this vulnerability

Trust: 0.8

url:provide a vendor statement

Trust: 0.8

url:https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-5401

Trust: 0.8

url:https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-5402

Trust: 0.8

url:https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-5399

Trust: 0.8

url:https://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2018-5400

Trust: 0.8

url:https://jvn.jp/vu/jvnvu99039923/

Trust: 0.8

url:https://nvd.nist.gov/vuln/detail/cve-2018-5399

Trust: 0.8

url:https://nvd.nist.gov/vuln/detail/cve-2018-5400

Trust: 0.8

url:https://nvd.nist.gov/vuln/detail/cve-2018-5401

Trust: 0.8

url:https://nvd.nist.gov/vuln/detail/cve-2018-5402

Trust: 0.8

url:https://www.auscert.org.au/bulletins/esb-2020.0648/

Trust: 0.6

url:https://www.auto-maskin.com/

Trust: 0.3

sources: CERT/CC: VU#176301 // VULHUB: VHN-135431 // BID: 105714 // JVNDB: JVNDB-2018-008149 // CNNVD: CNNVD-201810-260 // NVD: CVE-2018-5400

CREDITS

Brian Satira and Brian Olson

Trust: 0.3

sources: BID: 105714

SOURCES

db:CERT/CCid:VU#176301
db:VULHUBid:VHN-135431
db:BIDid:105714
db:JVNDBid:JVNDB-2018-008149
db:CNNVDid:CNNVD-201810-260
db:NVDid:CVE-2018-5400

LAST UPDATE DATE

2024-11-23T21:38:03.760000+00:00


SOURCES UPDATE DATE

db:CERT/CCid:VU#176301date:2018-10-16T00:00:00
db:VULHUBid:VHN-135431date:2019-10-09T00:00:00
db:BIDid:105714date:2018-10-06T00:00:00
db:JVNDBid:JVNDB-2018-008149date:2019-08-28T00:00:00
db:CNNVDid:CNNVD-201810-260date:2020-02-25T00:00:00
db:NVDid:CVE-2018-5400date:2024-11-21T04:08:44.580

SOURCES RELEASE DATE

db:CERT/CCid:VU#176301date:2018-10-06T00:00:00
db:VULHUBid:VHN-135431date:2018-10-08T00:00:00
db:BIDid:105714date:2018-10-06T00:00:00
db:JVNDBid:JVNDB-2018-008149date:2018-10-10T00:00:00
db:CNNVDid:CNNVD-201810-260date:2018-10-09T00:00:00
db:NVDid:CVE-2018-5400date:2018-10-08T15:29:02.727