ID

VAR-201806-1807


TITLE

Denial of service vulnerability in MMS protocol of Sifang CSI-200EA measurement and control device

Trust: 0.6

sources: CNVD: CNVD-2018-10960

DESCRIPTION

CSI-200EA measurement control device is mainly used in substation automation systems with voltage levels of 110kV and above. There is a denial of service vulnerability in the MMS protocol of Sifang CSI-200EA measurement and control device. An attacker can exploit the vulnerability to send a specific message of the TPKT layer of the MMS protocol, causing the device buffer to overflow

Trust: 0.72

sources: CNVD: CNVD-2018-10960 // IVD: e2f41a71-39ab-11e9-96b1-000c29342cb1

IOT TAXONOMY

category:['ICS']sub_category: -

Trust: 0.8

sources: IVD: e2f41a71-39ab-11e9-96b1-000c29342cb1 // CNVD: CNVD-2018-10960

AFFECTED PRODUCTS

vendor:sifang jibao automationmodel:csi-200ea measurement control devicescope: - version: -

Trust: 0.6

vendor:sifang jibao automationmodel:csi-200ea measurement control devicescope:eqversion:*

Trust: 0.2

sources: IVD: e2f41a71-39ab-11e9-96b1-000c29342cb1 // CNVD: CNVD-2018-10960

CVSS

SEVERITY

CVSSV2

CVSSV3

CNVD: CNVD-2018-10960
value: MEDIUM

Trust: 0.6

IVD: e2f41a71-39ab-11e9-96b1-000c29342cb1
value: MEDIUM

Trust: 0.2

CNVD: CNVD-2018-10960
severity: MEDIUM
baseScore: 6.1
vectorString: AV:A/AC:L/AU:N/C:N/I:N/A:C
accessVector: ADJACENT_NETWORK
accessComplexity: LOW
authentication: NONE
confidentialityImpact: NONE
integrityImpact: NONE
availabilityImpact: COMPLETE
exploitabilityScore: 6.5
impactScore: 6.9
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.6

IVD: e2f41a71-39ab-11e9-96b1-000c29342cb1
severity: MEDIUM
baseScore: 6.1
vectorString: AV:A/AC:L/AU:N/C:N/I:N/A:C
accessVector: ADJACENT_NETWORK
accessComplexity: LOW
authentication: NONE
confidentialityImpact: NONE
integrityImpact: NONE
availabilityImpact: COMPLETE
exploitabilityScore: 6.5
impactScore: 6.9
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.9 [IVD]

Trust: 0.2

sources: IVD: e2f41a71-39ab-11e9-96b1-000c29342cb1 // CNVD: CNVD-2018-10960

TYPE

Denial of service

Trust: 0.2

sources: IVD: e2f41a71-39ab-11e9-96b1-000c29342cb1

PATCH

title:Denial of service vulnerability in MMS protocol of Sifang CSI-200EA measurement and control deviceurl:https://www.cnvd.org.cn/patchinfo/show/130397

Trust: 0.6

sources: CNVD: CNVD-2018-10960

EXTERNAL IDS

db:CNVDid:CNVD-2018-10960

Trust: 0.8

db:IVDid:E2F41A71-39AB-11E9-96B1-000C29342CB1

Trust: 0.2

sources: IVD: e2f41a71-39ab-11e9-96b1-000c29342cb1 // CNVD: CNVD-2018-10960

SOURCES

db:IVDid:e2f41a71-39ab-11e9-96b1-000c29342cb1
db:CNVDid:CNVD-2018-10960

LAST UPDATE DATE

2022-05-17T01:45:09.993000+00:00


SOURCES UPDATE DATE

db:CNVDid:CNVD-2018-10960date:2018-06-25T00:00:00

SOURCES RELEASE DATE

db:IVDid:e2f41a71-39ab-11e9-96b1-000c29342cb1date:2018-06-05T00:00:00
db:CNVDid:CNVD-2018-10960date:2018-07-13T00:00:00