ID

VAR-201710-0718


CVE

CVE-2017-15567


TITLE

MorphoSmart 1300 Series access control vulnerability

Trust: 0.8

sources: JVNDB: JVNDB-2017-009609

DESCRIPTION

The certificate import component in IDEMIA (formerly Morpho) MorphoSmart 1300 Series (aka MSO 1300 Series) devices allows local users to obtain a command shell, and consequently gain privileges, via unspecified vectors. NOTE: the vendor disputes this because there is no command shell in the product or in the associated SDK. IDEMIA ( Old Morpho) MorphoSmart 1300 series ( alias MSO 1300 series ) Contains an access control vulnerability.Information is obtained, information is altered, and service operation is disrupted (DoS) There is a possibility of being put into a state. IDEMIA (formerly known as Morpho) MorphoSmart 1300 Series (also known as MSO 1300 Series) devices is a fingerprint identification device produced by French company IDEMIA (formerly known as Morpho). The certificate import component is one of the certificate import components. There is a security vulnerability in the certificate import module in IDEMIA MSO 1300 Series devices. A local attacker can exploit this vulnerability to obtain a command shell, thereby gaining privileges

Trust: 1.71

sources: NVD: CVE-2017-15567 // JVNDB: JVNDB-2017-009609 // VULHUB: VHN-106402

AFFECTED PRODUCTS

vendor:idemiamodel:mso 1300scope:eqversion: -

Trust: 1.0

vendor:morphomodel:morphosmart 1300 seriesscope: - version: -

Trust: 0.8

vendor:morphomodel:mso 1300scope:eqversion: -

Trust: 0.6

sources: JVNDB: JVNDB-2017-009609 // CNNVD: CNNVD-201710-1076 // NVD: CVE-2017-15567

CVSS

SEVERITY

CVSSV2

CVSSV3

nvd@nist.gov: CVE-2017-15567
value: HIGH

Trust: 1.0

NVD: CVE-2017-15567
value: HIGH

Trust: 0.8

CNNVD: CNNVD-201710-1076
value: HIGH

Trust: 0.6

VULHUB: VHN-106402
value: HIGH

Trust: 0.1

nvd@nist.gov: CVE-2017-15567
severity: HIGH
baseScore: 7.2
vectorString: AV:L/AC:L/AU:N/C:C/I:C/A:C
accessVector: LOCAL
accessComplexity: LOW
authentication: NONE
confidentialityImpact: COMPLETE
integrityImpact: COMPLETE
availabilityImpact: COMPLETE
exploitabilityScore: 3.9
impactScore: 10.0
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 1.8

VULHUB: VHN-106402
severity: HIGH
baseScore: 7.2
vectorString: AV:L/AC:L/AU:N/C:C/I:C/A:C
accessVector: LOCAL
accessComplexity: LOW
authentication: NONE
confidentialityImpact: COMPLETE
integrityImpact: COMPLETE
availabilityImpact: COMPLETE
exploitabilityScore: 3.9
impactScore: 10.0
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.1

nvd@nist.gov: CVE-2017-15567
baseSeverity: HIGH
baseScore: 7.8
vectorString: CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
attackVector: LOCAL
attackComplexity: LOW
privilegesRequired: LOW
userInteraction: NONE
scope: UNCHANGED
confidentialityImpact: HIGH
integrityImpact: HIGH
availabilityImpact: HIGH
exploitabilityScore: 1.8
impactScore: 5.9
version: 3.0

Trust: 1.8

sources: VULHUB: VHN-106402 // JVNDB: JVNDB-2017-009609 // CNNVD: CNNVD-201710-1076 // NVD: CVE-2017-15567

PROBLEMTYPE DATA

problemtype:NVD-CWE-noinfo

Trust: 1.0

problemtype:CWE-284

Trust: 0.9

sources: VULHUB: VHN-106402 // JVNDB: JVNDB-2017-009609 // NVD: CVE-2017-15567

THREAT TYPE

local

Trust: 0.6

sources: CNNVD: CNNVD-201710-1076

TYPE

lack of information

Trust: 0.6

sources: CNNVD: CNNVD-201710-1076

CONFIGURATIONS

sources: JVNDB: JVNDB-2017-009609

PATCH

title:MorphoSmart 1300 Seriesurl:https://www.morpho.com/en/biometric-terminals/desktop-devices/fingerprint-devices/morphosmart-1300-series

Trust: 0.8

sources: JVNDB: JVNDB-2017-009609

EXTERNAL IDS

db:NVDid:CVE-2017-15567

Trust: 2.5

db:JVNDBid:JVNDB-2017-009609

Trust: 0.8

db:CNNVDid:CNNVD-201710-1076

Trust: 0.7

db:VULHUBid:VHN-106402

Trust: 0.1

sources: VULHUB: VHN-106402 // JVNDB: JVNDB-2017-009609 // CNNVD: CNNVD-201710-1076 // NVD: CVE-2017-15567

REFERENCES

url:https://gist.github.com/shiham101/4c49ece8ecac7c3c02ecbc6942aeca80

Trust: 2.5

url:http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2017-15567

Trust: 0.8

url:https://nvd.nist.gov/vuln/detail/cve-2017-15567

Trust: 0.8

sources: VULHUB: VHN-106402 // JVNDB: JVNDB-2017-009609 // CNNVD: CNNVD-201710-1076 // NVD: CVE-2017-15567

SOURCES

db:VULHUBid:VHN-106402
db:JVNDBid:JVNDB-2017-009609
db:CNNVDid:CNNVD-201710-1076
db:NVDid:CVE-2017-15567

LAST UPDATE DATE

2025-04-20T23:15:53.352000+00:00


SOURCES UPDATE DATE

db:VULHUBid:VHN-106402date:2019-10-03T00:00:00
db:JVNDBid:JVNDB-2017-009609date:2017-11-16T00:00:00
db:CNNVDid:CNNVD-201710-1076date:2019-10-23T00:00:00
db:NVDid:CVE-2017-15567date:2025-04-20T01:37:25.860

SOURCES RELEASE DATE

db:VULHUBid:VHN-106402date:2017-10-23T00:00:00
db:JVNDBid:JVNDB-2017-009609date:2017-11-16T00:00:00
db:CNNVDid:CNNVD-201710-1076date:2017-10-31T00:00:00
db:NVDid:CVE-2017-15567date:2017-10-23T08:29:00.680