ID

VAR-201412-0558


CVE

CVE-2014-8512


TITLE

Schneider Electric ProClima of Atx45.ocx of ActiveX Control buffer overflow vulnerability

Trust: 0.8

sources: JVNDB: JVNDB-2014-007421

DESCRIPTION

Buffer overflow in an ActiveX control in Atx45.ocx in Schneider Electric ProClima before 6.1.7 allows remote attackers to execute arbitrary code via unspecified vectors, a different vulnerability than CVE-2014-8511. NOTE: this may be clarified later based on details provided by researchers. This vulnerability CVE-2014-8511 Is a different vulnerability. The details of this issue may become clear in the future based on information provided by researchers.A third party may execute arbitrary code. User interaction is required to exploit this vulnerability in that the target must visit a malicious page or open a malicious file.The specific flaw exists within the ATX45.ATX45Ctrl.1 ActiveX control in Atx45.ocx. The control does not check the length of an attacker-supplied string in the SetBodyAttribute method before copying it into a fixed length buffer on the heap. This allows an attacker to execute arbitrary code in the context of the browser process. Schneider Electric provides total solutions for the energy and infrastructure, industrial, data center and network, building and residential markets in more than 100 countries. Failed exploit attempts will likely result in denial-of-service conditions. ProClima 6.0.1 and prior are vulnerable. Schneider Electric ProClima is a set of thermal calculation software from Schneider Electric, France

Trust: 3.33

sources: NVD: CVE-2014-8512 // JVNDB: JVNDB-2014-007421 // ZDI: ZDI-15-004 // CNVD: CNVD-2014-09024 // BID: 71711 // IVD: ae2f226c-2351-11e6-abef-000c29c66e3d // VULHUB: VHN-76457

IOT TAXONOMY

category:['ICS']sub_category: -

Trust: 0.8

sources: IVD: ae2f226c-2351-11e6-abef-000c29c66e3d // CNVD: CNVD-2014-09024

AFFECTED PRODUCTS

vendor:schneider electricmodel:proclimascope:lteversion:6.0.1

Trust: 1.0

vendor:schneider electricmodel:proclimascope:ltversion:6.1.7

Trust: 0.8

vendor:schneider electricmodel:proclimascope: - version: -

Trust: 0.7

vendor:schneidermodel:electric proclimascope:ltversion:6.0.1

Trust: 0.6

vendor:schneider electricmodel:proclimascope:eqversion:6.0.1

Trust: 0.6

vendor:proclimamodel: - scope:eqversion:*

Trust: 0.2

sources: IVD: ae2f226c-2351-11e6-abef-000c29c66e3d // ZDI: ZDI-15-004 // CNVD: CNVD-2014-09024 // JVNDB: JVNDB-2014-007421 // CNNVD: CNNVD-201412-570 // NVD: CVE-2014-8512

CVSS

SEVERITY

CVSSV2

CVSSV3

nvd@nist.gov: CVE-2014-8512
value: HIGH

Trust: 1.0

NVD: CVE-2014-8512
value: HIGH

Trust: 0.8

ZDI: CVE-2014-8512
value: HIGH

Trust: 0.7

CNVD: CNVD-2014-09024
value: HIGH

Trust: 0.6

CNNVD: CNNVD-201412-570
value: HIGH

Trust: 0.6

IVD: ae2f226c-2351-11e6-abef-000c29c66e3d
value: HIGH

Trust: 0.2

VULHUB: VHN-76457
value: HIGH

Trust: 0.1

nvd@nist.gov: CVE-2014-8512
severity: HIGH
baseScore: 7.5
vectorString: AV:N/AC:L/AU:N/C:P/I:P/A:P
accessVector: NETWORK
accessComplexity: LOW
authentication: NONE
confidentialityImpact: PARTIAL
integrityImpact: PARTIAL
availabilityImpact: PARTIAL
exploitabilityScore: 10.0
impactScore: 6.4
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 2.5

CNVD: CNVD-2014-09024
severity: HIGH
baseScore: 7.5
vectorString: AV:N/AC:L/AU:N/C:P/I:P/A:P
accessVector: NETWORK
accessComplexity: LOW
authentication: NONE
confidentialityImpact: PARTIAL
integrityImpact: PARTIAL
availabilityImpact: PARTIAL
exploitabilityScore: 10.0
impactScore: 6.4
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.6

IVD: ae2f226c-2351-11e6-abef-000c29c66e3d
severity: HIGH
baseScore: 7.5
vectorString: AV:N/AC:L/AU:N/C:P/I:P/A:P
accessVector: NETWORK
accessComplexity: LOW
authentication: NONE
confidentialityImpact: PARTIAL
integrityImpact: PARTIAL
availabilityImpact: PARTIAL
exploitabilityScore: 10.0
impactScore: 6.4
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.9 [IVD]

Trust: 0.2

VULHUB: VHN-76457
severity: HIGH
baseScore: 7.5
vectorString: AV:N/AC:L/AU:N/C:P/I:P/A:P
accessVector: NETWORK
accessComplexity: LOW
authentication: NONE
confidentialityImpact: PARTIAL
integrityImpact: PARTIAL
availabilityImpact: PARTIAL
exploitabilityScore: 10.0
impactScore: 6.4
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.1

sources: IVD: ae2f226c-2351-11e6-abef-000c29c66e3d // ZDI: ZDI-15-004 // CNVD: CNVD-2014-09024 // VULHUB: VHN-76457 // JVNDB: JVNDB-2014-007421 // CNNVD: CNNVD-201412-570 // NVD: CVE-2014-8512

PROBLEMTYPE DATA

problemtype:CWE-119

Trust: 1.9

sources: VULHUB: VHN-76457 // JVNDB: JVNDB-2014-007421 // NVD: CVE-2014-8512

THREAT TYPE

remote

Trust: 0.6

sources: CNNVD: CNNVD-201412-570

TYPE

Buffer overflow

Trust: 0.8

sources: IVD: ae2f226c-2351-11e6-abef-000c29c66e3d // CNNVD: CNNVD-201412-570

CONFIGURATIONS

sources: JVNDB: JVNDB-2014-007421

PATCH

title:ProClima Software Vulnerability Disclosureurl:http://download.schneider-electric.com/files?p_Doc_Ref=SEVD%202014-344-01

Trust: 0.8

title:Schneider Electric has issued an update to correct this vulnerability.url:https://ics-cert.us-cert.gov/advisories/ICSA-14-350-01

Trust: 0.7

title:Patch for Schneider Electric ProClima Remote Buffer Overflow Vulnerability (CNVD-2014-09024)url:https://www.cnvd.org.cn/patchInfo/show/52959

Trust: 0.6

sources: ZDI: ZDI-15-004 // CNVD: CNVD-2014-09024 // JVNDB: JVNDB-2014-007421

EXTERNAL IDS

db:NVDid:CVE-2014-8512

Trust: 4.3

db:ICS CERTid:ICSA-14-350-01

Trust: 2.5

db:BIDid:71711

Trust: 1.0

db:CNNVDid:CNNVD-201412-570

Trust: 0.9

db:CNVDid:CNVD-2014-09024

Trust: 0.8

db:JVNDBid:JVNDB-2014-007421

Trust: 0.8

db:ZDI_CANid:ZDI-CAN-2479

Trust: 0.7

db:ZDIid:ZDI-15-004

Trust: 0.7

db:IVDid:AE2F226C-2351-11E6-ABEF-000C29C66E3D

Trust: 0.2

db:VULHUBid:VHN-76457

Trust: 0.1

sources: IVD: ae2f226c-2351-11e6-abef-000c29c66e3d // ZDI: ZDI-15-004 // CNVD: CNVD-2014-09024 // VULHUB: VHN-76457 // BID: 71711 // JVNDB: JVNDB-2014-007421 // CNNVD: CNNVD-201412-570 // NVD: CVE-2014-8512

REFERENCES

url:https://ics-cert.us-cert.gov/advisories/icsa-14-350-01

Trust: 3.2

url:http://download.schneider-electric.com/files?p_doc_ref=sevd%202014-344-01

Trust: 1.7

url:http://cve.mitre.org/cgi-bin/cvename.cgi?name=cve-2014-8512

Trust: 0.8

url:http://web.nvd.nist.gov/view/vuln/detail?vulnid=cve-2014-8512

Trust: 0.8

url:http://www.securityfocus.com/bid/71711

Trust: 0.6

url:http://www.schneider-electric.com/site/home/index.cfm/ww/?selectcountry=true

Trust: 0.3

sources: ZDI: ZDI-15-004 // CNVD: CNVD-2014-09024 // VULHUB: VHN-76457 // BID: 71711 // JVNDB: JVNDB-2014-007421 // CNNVD: CNNVD-201412-570 // NVD: CVE-2014-8512

CREDITS

Brian Gorenc - HP Zero Day Initiative

Trust: 0.7

sources: ZDI: ZDI-15-004

SOURCES

db:IVDid:ae2f226c-2351-11e6-abef-000c29c66e3d
db:ZDIid:ZDI-15-004
db:CNVDid:CNVD-2014-09024
db:VULHUBid:VHN-76457
db:BIDid:71711
db:JVNDBid:JVNDB-2014-007421
db:CNNVDid:CNNVD-201412-570
db:NVDid:CVE-2014-8512

LAST UPDATE DATE

2025-04-12T23:09:13.985000+00:00


SOURCES UPDATE DATE

db:ZDIid:ZDI-15-004date:2015-01-07T00:00:00
db:CNVDid:CNVD-2014-09024date:2014-12-19T00:00:00
db:VULHUBid:VHN-76457date:2014-12-29T00:00:00
db:BIDid:71711date:2015-01-12T00:02:00
db:JVNDBid:JVNDB-2014-007421date:2015-01-06T00:00:00
db:CNNVDid:CNNVD-201412-570date:2015-01-04T00:00:00
db:NVDid:CVE-2014-8512date:2025-04-12T10:46:40.837

SOURCES RELEASE DATE

db:IVDid:ae2f226c-2351-11e6-abef-000c29c66e3ddate:2014-12-19T00:00:00
db:ZDIid:ZDI-15-004date:2015-01-07T00:00:00
db:CNVDid:CNVD-2014-09024date:2014-12-19T00:00:00
db:VULHUBid:VHN-76457date:2014-12-27T00:00:00
db:BIDid:71711date:2014-12-10T00:00:00
db:JVNDBid:JVNDB-2014-007421date:2015-01-06T00:00:00
db:CNNVDid:CNNVD-201412-570date:2014-12-27T00:00:00
db:NVDid:CVE-2014-8512date:2014-12-27T15:59:01.857