ID

VAR-201402-0440


TITLE

Schneider Electric SCADAPack VxWorks Debugger Device Control Vulnerability

Trust: 0.8

sources: IVD: f510e5e4-1eec-11e6-abef-000c29c66e3d // CNVD: CNVD-2014-00942

DESCRIPTION

Schneider Electric SCADAPack is a telemetry, remote SCADA system solution. Schneider Electric SCADAPack enables the VxWorks debug agent, allowing remote attackers to exploit vulnerabilities to send specially crafted requests to the UDP/17185 port to control devices

Trust: 0.72

sources: CNVD: CNVD-2014-00942 // IVD: f510e5e4-1eec-11e6-abef-000c29c66e3d

IOT TAXONOMY

category:['ICS']sub_category: -

Trust: 0.8

sources: IVD: f510e5e4-1eec-11e6-abef-000c29c66e3d // CNVD: CNVD-2014-00942

AFFECTED PRODUCTS

vendor:schneidermodel:electric scadapackscope:eqversion:33x

Trust: 0.8

sources: IVD: f510e5e4-1eec-11e6-abef-000c29c66e3d // CNVD: CNVD-2014-00942

CVSS

SEVERITY

CVSSV2

CVSSV3

CNVD: CNVD-2014-00942
value: MEDIUM

Trust: 0.6

IVD: f510e5e4-1eec-11e6-abef-000c29c66e3d
value: MEDIUM

Trust: 0.2

CNVD: CNVD-2014-00942
severity: MEDIUM
baseScore: 5.0
vectorString: AV:N/AC:L/AU:N/C:N/I:P/A:N
accessVector: NETWORK
accessComplexity: LOW
authentication: NONE
confidentialityImpact: NONE
integrityImpact: PARTIAL
availabilityImpact: NONE
exploitabilityScore: 10.0
impactScore: 2.9
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.0

Trust: 0.6

IVD: f510e5e4-1eec-11e6-abef-000c29c66e3d
severity: MEDIUM
baseScore: 5.0
vectorString: AV:N/AC:L/AU:N/C:N/I:P/A:N
accessVector: NETWORK
accessComplexity: LOW
authentication: NONE
confidentialityImpact: NONE
integrityImpact: PARTIAL
availabilityImpact: NONE
exploitabilityScore: 10.0
impactScore: 2.9
acInsufInfo: NONE
obtainAllPrivilege: NONE
obtainUserPrivilege: NONE
obtainOtherPrivilege: NONE
userInteractionRequired: NONE
version: 2.9 [IVD]

Trust: 0.2

sources: IVD: f510e5e4-1eec-11e6-abef-000c29c66e3d // CNVD: CNVD-2014-00942

TYPE

Permission permission and access control

Trust: 0.2

sources: IVD: f510e5e4-1eec-11e6-abef-000c29c66e3d

PATCH

title:Schneider Electric SCADAPack VxWorks Debugger Device Control Vulnerability Patchurl:https://www.cnvd.org.cn/patchinfo/show/43575

Trust: 0.6

sources: CNVD: CNVD-2014-00942

EXTERNAL IDS

db:CNVDid:CNVD-2014-00942

Trust: 0.8

db:SECUNIAid:56811

Trust: 0.6

db:IVDid:F510E5E4-1EEC-11E6-ABEF-000C29C66E3D

Trust: 0.2

sources: IVD: f510e5e4-1eec-11e6-abef-000c29c66e3d // CNVD: CNVD-2014-00942

REFERENCES

url:http://download.schneider-electric.com/files?p_doc_ref=sevd%202013-345-01

Trust: 0.6

url:http://secunia.com/advisories/56811/

Trust: 0.6

sources: CNVD: CNVD-2014-00942

SOURCES

db:IVDid:f510e5e4-1eec-11e6-abef-000c29c66e3d
db:CNVDid:CNVD-2014-00942

LAST UPDATE DATE

2022-05-17T01:48:03.148000+00:00


SOURCES UPDATE DATE

db:CNVDid:CNVD-2014-00942date:2014-02-17T00:00:00

SOURCES RELEASE DATE

db:IVDid:f510e5e4-1eec-11e6-abef-000c29c66e3ddate:2014-02-14T00:00:00
db:CNVDid:CNVD-2014-00942date:2014-02-14T00:00:00